Loading…

A universal assay strategy for sensitive and simultaneous quantitation of multiplex tumor markers based on the stirring rod-immobilized DNA-LaMnO3 perovskite-metal ions encoded probes

It was extremely urgent to develop some simultaneous and sensitive biosensors for detecting multiplex serum tumor markers (TMs) for early screening of cancers. Herein, a multiplex assay was developed based on the DNA-LaMnO3 (DNA-LMO) perovskite encoded probes and targets mediated competitive replace...

Full description

Saved in:
Bibliographic Details
Published in:Talanta (Oxford) 2021-01, Vol.222, p.121456-121456, Article 121456
Main Authors: Wang, Wenhai, Wang, Qiqin, Xie, Hongzhen, Wu, Dazhen, Gan, Ning
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:It was extremely urgent to develop some simultaneous and sensitive biosensors for detecting multiplex serum tumor markers (TMs) for early screening of cancers. Herein, a multiplex assay was developed based on the DNA-LaMnO3 (DNA-LMO) perovskite encoded probes and targets mediated competitive replacement strategy. Alpha fetoprotein (AFP), carcinoembryonic antigen (CEA) and prostate specific antigen (PSA) markers were employed as representative target TMs. Aptasensor is prepared by a series of DNA-LMO-M encode probes which were prepared by three hyperbranched DNA firstly immobilized on LMO encapsulating Pb, Cd or Cu ions. Then, three TMs aptamers were labeled on the stirring-rod and hybridized with the probes. After the developed encoded probes was incubated the TMs, the encoded probes corresponding to different TMs can be released into the supernatant through the competitive replacement. The inner metal ion can be simultaneously detected by square wave voltammetry corresponding to various TMs. Since the stirring rod can enrich many encoded probes containing a lot of metal ions, multiplex signal amplification can be realized. Due to the enrichment and easy separation of the stirring rod, the signal-to-noise ratio was also obviously improved and thus to results in good sensitivity and accuracy. Moreover, it took only 20 min to detect three targets which much faster than many same types of aptasensor. Under the optimal conditions, the low detection limit for CEA (3.6 × 10-4 ng/mL), AFP (3.4 × 10-4 ng/mL) and PSA (2.8 × 10-4 ng/mL) were obtained. Therefore, this method is likely to be used for early and sensitive screening of tumors. [Display omitted] •An aptasensor for simultaneous detecting multiple tumor markers was constructed.•Hyperbranched DNA-LaMnO3 Perovskite encoded probes were used for multi-analysis.•The encoded probes can achieve zero-background and triple signal amplification.•The sensor can rapidly detect 3 TMs in serum at pg/mL magnitude within 20 min.
ISSN:0039-9140
1873-3573
DOI:10.1016/j.talanta.2020.121456