Loading…

His bundle pacing: Tips and tricks

His bundle (HB) pacing is an established modality for achieving physiological pacing with a low risk of long‐term lead‐related complications. The development of specially designed lead and delivery tools has improved the feasibility and safety of HB pacing (HBP). Knowledge of the anatomy of HB regio...

Full description

Saved in:
Bibliographic Details
Published in:Pacing and clinical electrophysiology 2021-01, Vol.44 (1), p.26-34
Main Authors: Ravi, Venkatesh, El Baba, Mohammad, Sharma, Parikshit S.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c4238-4f6927a82abc374c31ef334d23629f1badbe39501718f426036db9fab3f6b1e3
cites cdi_FETCH-LOGICAL-c4238-4f6927a82abc374c31ef334d23629f1badbe39501718f426036db9fab3f6b1e3
container_end_page 34
container_issue 1
container_start_page 26
container_title Pacing and clinical electrophysiology
container_volume 44
creator Ravi, Venkatesh
El Baba, Mohammad
Sharma, Parikshit S.
description His bundle (HB) pacing is an established modality for achieving physiological pacing with a low risk of long‐term lead‐related complications. The development of specially designed lead and delivery tools has improved the feasibility and safety of HB pacing (HBP). Knowledge of the anatomy of HB region and the variations is essential for successful implantation. Newer delivery systems have further improved procedural outcomes. Challenging implant cases can be successfully performed by reshaping the current sheaths, using “sheath in sheath” technique or “two‐lead implantation technique.” Special attention to the lead parameters at implant, programming, and follow‐up is necessary for successful long‐term outcomes with HBP. Widespread use of HBP by electrophysiologists and further advances in dedicated delivery systems and leads are essential to further improve the effectiveness of the implantation.
doi_str_mv 10.1111/pace.14108
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2459627592</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2478758825</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4238-4f6927a82abc374c31ef334d23629f1badbe39501718f426036db9fab3f6b1e3</originalsourceid><addsrcrecordid>eNp90E9LwzAYx_EgipvTiy9Ail5E6MyT__U2xnTCQA-7h6RNpLNrZ7Mie_dmdnrwYC65fPjy8EPoEvAY4rvfmNyNgQFWR2gInOFUAc-O0RADk6miKhugsxBWGGOBGT9FA0pBMgJiiK7nZUhsVxeVS2KnrN8ekmW5CYmpi2Tblvl7OEcn3lTBXRz-EVo-zpbTebp4eXqeThZpzghVKfMiI9IoYmxOJcspOE8pKwgVJPNgTWEdzTgGCcozIjAVhc28sdQLC46O0G2f3bTNR-fCVq_LkLuqMrVruqAJ45kgkmck0ps_dNV0bR2Pi0oqyZUiPKq7XuVtE0LrvN605dq0Ow1Y74fT--H093ARXx2SnV274pf-LBUB9OCzrNzun5R-nUxnffQLFGV0vg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2478758825</pqid></control><display><type>article</type><title>His bundle pacing: Tips and tricks</title><source>Wiley</source><source>SPORTDiscus with Full Text</source><creator>Ravi, Venkatesh ; El Baba, Mohammad ; Sharma, Parikshit S.</creator><creatorcontrib>Ravi, Venkatesh ; El Baba, Mohammad ; Sharma, Parikshit S.</creatorcontrib><description>His bundle (HB) pacing is an established modality for achieving physiological pacing with a low risk of long‐term lead‐related complications. The development of specially designed lead and delivery tools has improved the feasibility and safety of HB pacing (HBP). Knowledge of the anatomy of HB region and the variations is essential for successful implantation. Newer delivery systems have further improved procedural outcomes. Challenging implant cases can be successfully performed by reshaping the current sheaths, using “sheath in sheath” technique or “two‐lead implantation technique.” Special attention to the lead parameters at implant, programming, and follow‐up is necessary for successful long‐term outcomes with HBP. Widespread use of HBP by electrophysiologists and further advances in dedicated delivery systems and leads are essential to further improve the effectiveness of the implantation.</description><identifier>ISSN: 0147-8389</identifier><identifier>EISSN: 1540-8159</identifier><identifier>DOI: 10.1111/pace.14108</identifier><identifier>PMID: 33174216</identifier><language>eng</language><publisher>United States: Wiley Subscription Services, Inc</publisher><subject>challenging implant ; His bundle anatomy ; His bundle pacing ; His delivery sheath modification ; Sheaths ; tips and tricks</subject><ispartof>Pacing and clinical electrophysiology, 2021-01, Vol.44 (1), p.26-34</ispartof><rights>2020 Wiley Periodicals LLC</rights><rights>2020 Wiley Periodicals LLC.</rights><rights>2021 Wiley Periodicals LLC</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4238-4f6927a82abc374c31ef334d23629f1badbe39501718f426036db9fab3f6b1e3</citedby><cites>FETCH-LOGICAL-c4238-4f6927a82abc374c31ef334d23629f1badbe39501718f426036db9fab3f6b1e3</cites><orcidid>0000-0001-6826-9231 ; 0000-0002-7999-476X</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/33174216$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ravi, Venkatesh</creatorcontrib><creatorcontrib>El Baba, Mohammad</creatorcontrib><creatorcontrib>Sharma, Parikshit S.</creatorcontrib><title>His bundle pacing: Tips and tricks</title><title>Pacing and clinical electrophysiology</title><addtitle>Pacing Clin Electrophysiol</addtitle><description>His bundle (HB) pacing is an established modality for achieving physiological pacing with a low risk of long‐term lead‐related complications. The development of specially designed lead and delivery tools has improved the feasibility and safety of HB pacing (HBP). Knowledge of the anatomy of HB region and the variations is essential for successful implantation. Newer delivery systems have further improved procedural outcomes. Challenging implant cases can be successfully performed by reshaping the current sheaths, using “sheath in sheath” technique or “two‐lead implantation technique.” Special attention to the lead parameters at implant, programming, and follow‐up is necessary for successful long‐term outcomes with HBP. Widespread use of HBP by electrophysiologists and further advances in dedicated delivery systems and leads are essential to further improve the effectiveness of the implantation.</description><subject>challenging implant</subject><subject>His bundle anatomy</subject><subject>His bundle pacing</subject><subject>His delivery sheath modification</subject><subject>Sheaths</subject><subject>tips and tricks</subject><issn>0147-8389</issn><issn>1540-8159</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNp90E9LwzAYx_EgipvTiy9Ail5E6MyT__U2xnTCQA-7h6RNpLNrZ7Mie_dmdnrwYC65fPjy8EPoEvAY4rvfmNyNgQFWR2gInOFUAc-O0RADk6miKhugsxBWGGOBGT9FA0pBMgJiiK7nZUhsVxeVS2KnrN8ekmW5CYmpi2Tblvl7OEcn3lTBXRz-EVo-zpbTebp4eXqeThZpzghVKfMiI9IoYmxOJcspOE8pKwgVJPNgTWEdzTgGCcozIjAVhc28sdQLC46O0G2f3bTNR-fCVq_LkLuqMrVruqAJ45kgkmck0ps_dNV0bR2Pi0oqyZUiPKq7XuVtE0LrvN605dq0Ow1Y74fT--H093ARXx2SnV274pf-LBUB9OCzrNzun5R-nUxnffQLFGV0vg</recordid><startdate>202101</startdate><enddate>202101</enddate><creator>Ravi, Venkatesh</creator><creator>El Baba, Mohammad</creator><creator>Sharma, Parikshit S.</creator><general>Wiley Subscription Services, Inc</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7TK</scope><scope>NAPCQ</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-6826-9231</orcidid><orcidid>https://orcid.org/0000-0002-7999-476X</orcidid></search><sort><creationdate>202101</creationdate><title>His bundle pacing: Tips and tricks</title><author>Ravi, Venkatesh ; El Baba, Mohammad ; Sharma, Parikshit S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4238-4f6927a82abc374c31ef334d23629f1badbe39501718f426036db9fab3f6b1e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>challenging implant</topic><topic>His bundle anatomy</topic><topic>His bundle pacing</topic><topic>His delivery sheath modification</topic><topic>Sheaths</topic><topic>tips and tricks</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ravi, Venkatesh</creatorcontrib><creatorcontrib>El Baba, Mohammad</creatorcontrib><creatorcontrib>Sharma, Parikshit S.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>Neurosciences Abstracts</collection><collection>Nursing &amp; Allied Health Premium</collection><collection>MEDLINE - Academic</collection><jtitle>Pacing and clinical electrophysiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ravi, Venkatesh</au><au>El Baba, Mohammad</au><au>Sharma, Parikshit S.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>His bundle pacing: Tips and tricks</atitle><jtitle>Pacing and clinical electrophysiology</jtitle><addtitle>Pacing Clin Electrophysiol</addtitle><date>2021-01</date><risdate>2021</risdate><volume>44</volume><issue>1</issue><spage>26</spage><epage>34</epage><pages>26-34</pages><issn>0147-8389</issn><eissn>1540-8159</eissn><abstract>His bundle (HB) pacing is an established modality for achieving physiological pacing with a low risk of long‐term lead‐related complications. The development of specially designed lead and delivery tools has improved the feasibility and safety of HB pacing (HBP). Knowledge of the anatomy of HB region and the variations is essential for successful implantation. Newer delivery systems have further improved procedural outcomes. Challenging implant cases can be successfully performed by reshaping the current sheaths, using “sheath in sheath” technique or “two‐lead implantation technique.” Special attention to the lead parameters at implant, programming, and follow‐up is necessary for successful long‐term outcomes with HBP. Widespread use of HBP by electrophysiologists and further advances in dedicated delivery systems and leads are essential to further improve the effectiveness of the implantation.</abstract><cop>United States</cop><pub>Wiley Subscription Services, Inc</pub><pmid>33174216</pmid><doi>10.1111/pace.14108</doi><tpages>9</tpages><orcidid>https://orcid.org/0000-0001-6826-9231</orcidid><orcidid>https://orcid.org/0000-0002-7999-476X</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0147-8389
ispartof Pacing and clinical electrophysiology, 2021-01, Vol.44 (1), p.26-34
issn 0147-8389
1540-8159
language eng
recordid cdi_proquest_miscellaneous_2459627592
source Wiley; SPORTDiscus with Full Text
subjects challenging implant
His bundle anatomy
His bundle pacing
His delivery sheath modification
Sheaths
tips and tricks
title His bundle pacing: Tips and tricks
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-21T13%3A56%3A46IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=His%20bundle%20pacing:%20Tips%20and%20tricks&rft.jtitle=Pacing%20and%20clinical%20electrophysiology&rft.au=Ravi,%20Venkatesh&rft.date=2021-01&rft.volume=44&rft.issue=1&rft.spage=26&rft.epage=34&rft.pages=26-34&rft.issn=0147-8389&rft.eissn=1540-8159&rft_id=info:doi/10.1111/pace.14108&rft_dat=%3Cproquest_cross%3E2478758825%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c4238-4f6927a82abc374c31ef334d23629f1badbe39501718f426036db9fab3f6b1e3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2478758825&rft_id=info:pmid/33174216&rfr_iscdi=true