An optimized b‐value distribution for triexponential intravoxel incoherent motion (IVIM) in the liver
Purpose To find an optimized b‐value distribution for reproducible triexponential intravoxel incoherent motion (IVIM) exams in the liver. Methods A numeric optimization of b‐value distributions was performed using the triexponential IVIM equation and 27 different IVIM parameter sets. Starting with a...
Saved in:
Published in: | Magnetic resonance in medicine 2021-04, Vol.85 (4), p.2095-2108 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Purpose
To find an optimized b‐value distribution for reproducible triexponential intravoxel incoherent motion (IVIM) exams in the liver.
Methods
A numeric optimization of b‐value distributions was performed using the triexponential IVIM equation and 27 different IVIM parameter sets. Starting with an initially optimized distribution of 6 b‐values, the number of b‐values was increased stepwise. Each new b‐value was chosen from a set of 64 predefined b‐values based on the computed summed relative mean error of the fitted triexponential IVIM parameters. This process was repeated for up to 100 b‐values. In simulations and in vivo measurements, optimized b‐value distributions were compared to 4 representative distributions found in literature.
Results
The first 16 optimized b‐values were 0, 0.3, 0.3, 70, 200, 800, 70, 1, 3.5, 5, 70, 1.2, 6, 45, 1.5, and 60 in units of s/mm2. Low b‐values were much more frequent than high b‐values. The optimized b‐value distribution resulted in a higher fit stability compared to distributions used in literature in both, simulation and in vivo measurements. Using more than 6 b‐values, ideally 16 or more, increased the fit stability considerably.
Conclusion
Using optimized b‐values, the fit uncertainty in triexponential IVIM can be largely reduced. Ideally, 16 or more b‐values should be acquired. |
---|---|