Noninvasive detection of broken rotor bars in operating induction motors
A description is given of a computer-based noninvasive broken bar fault detector for squirrel-cage rotors of induction motors. The detector can be applied to existing motors without disassembly or shutdown and has the sensitivity to diagnose the presence of a single broken bar or an open end ring. I...
Saved in:
Published in: | IEEE transactions on energy conversion 1988-12, Vol.3 (4), p.873-879 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | A description is given of a computer-based noninvasive broken bar fault detector for squirrel-cage rotors of induction motors. The detector can be applied to existing motors without disassembly or shutdown and has the sensitivity to diagnose the presence of a single broken bar or an open end ring. It is suitable for monitoring the trend of the motor signature, or it can be used as a one-time diagnostic tool.< > |
---|---|