Loading…

Increased Ipsilateral Posterior Cerebral Artery P2-Segment Flow Velocity Predicts Hemodynamic Impairment

Increased Transcranial Doppler flow velocity in the ipsilateral P2-segment of the posterior cerebral artery (PCA-P2: cm/second) is associated with recurrent cerebrovascular events in patients with unilateral internal carotid artery occlusion. However, its predictive value and correlation with hemody...

Full description

Saved in:
Bibliographic Details
Published in:Stroke (1970) 2021-04, Vol.52 (4), p.1469-1472
Main Authors: van Niftrik, Christiaan H.B., Sebök, Martina, Wegener, Susanne, Esposito, Giuseppe, Halter, Matthias, Hiller, Aimee, Stippich, Christoph, Luft, Andreas R., Regli, Luca, Fierstra, Jorn
Format: Article
Language:English
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Increased Transcranial Doppler flow velocity in the ipsilateral P2-segment of the posterior cerebral artery (PCA-P2: cm/second) is associated with recurrent cerebrovascular events in patients with unilateral internal carotid artery occlusion. However, its predictive value and correlation with hemodynamic impairment in an overall stroke patient cohort remains to be determined. Transcranial doppler PCA-P2 flow velocity was measured in 88 patients with symptomatic unilateral steno-occlusive disease who also underwent blood oxygenation-level dependent cerebrovascular reactivity imaging (blood oxygenation-level dependent [BOLD]-cerebrovascular reactivity [CVR]). A multivariate linear regression was used to evaluate the independent correlation between the ipsilateral PCA-P2 flow velocity measurements and hemispheric BOLD-CVR. Follow-up BOLD-CVR imaging data, available in 25 patients, were used to evaluate the temporal evolution of the BOLD-CVR and PCA-P2 flow velocity association using a mixed-effect model. Furthermore, a transcranial doppler cutoff for hemodynamic failure stage 2 was determined. The ipsilateral systolic PCA-P2 flow velocity strongly correlated with hemispheric BOLD-CVR (R=0.79; R =0.61), which remained unchanged when evaluating the follow-up data. Using a PCA-P2 systolic flow velocity cutoff value of 85 cm/second, patients with BOLD-CVR based hemodynamic failure stage 2 were diagnosed with an area under the curve of 95. In patients with symptomatic unilateral steno-occlusive disease, increased ipsilateral transcranial doppler PCA-P2 systolic flow velocity independently correlates with BOLD-CVR based hemodynamic failure. A cutoff value of 85 cm/second appears to indicate hemodynamic failure stage 2, but this finding needs to be validated in an independent patient cohort.
ISSN:0039-2499
1524-4628
DOI:10.1161/STROKEAHA.120.032848