Loading…
Inter-reader reliability of CT Liver Imaging Reporting and Data System according to imaging analysis methodology: a systematic review and meta-analysis
Objectives To establish inter-reader reliability of CT Liver Imaging Reporting and Data System (LI-RADS) and explore factors that affect it. Methods MEDLINE and EMBASE databases were searched from January 2014 to March 2020 to identify original articles reporting the inter-reader reliability of CT L...
Saved in:
Published in: | European radiology 2021-09, Vol.31 (9), p.6856-6867 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Objectives
To establish inter-reader reliability of CT Liver Imaging Reporting and Data System (LI-RADS) and explore factors that affect it.
Methods
MEDLINE and EMBASE databases were searched from January 2014 to March 2020 to identify original articles reporting the inter-reader reliability of CT LI-RADS. The imaging analysis methodology of each study was identified, and pooled intraclass correlation coefficient (ICC) or kappa values (κ) were calculated for lesion size, major features (arterial-phase hyperenhancement [APHE], nonperipheral washout [WO], and enhancing capsule [EC]), and LI-RADS categorization (LR) using random-effects models. Subgroup analyses of pooled κ were performed for the number of readers, average reader experience, differences in reader experience, and LI-RADS version.
Results
In the 12 included studies, the pooled ICC or κ of lesion size, APHE, WO, EC, and LR were 0.99 (0.96−1.00), 0.69 (0.58–0.81), 0.67 (0.53–0.82), 0.65 (0.54–0.76), and 0.70 (0.59–0.82), respectively. The experience and number of readers varied: studies using readers with ≥ 10 years of experience showed significantly higher κ for LR (0.82 vs. 0.45,
p
= 0.01) than those with < 10 years of reader experience. Studies with multiple readers including inexperienced readers showed significantly lower κ for APHE (0.55 vs. 0.76,
p
= 0.04) and LR (0.45 vs. 0.79,
p
= 0.02) than those with all experienced readers.
Conclusions
CT LI-RADS showed substantial inter-reader reliability for major features and LR. Inter-reader reliability differed significantly according to average reader experience and differences in reader experience. Reported results for inter-reader reliability of CT LI-RADS should be understood with consideration of the imaging analysis methodology.
Key Points
• The CT Liver Imaging Reporting and Data System (LI-RADS) provides substantial inter-reader reliability for three major features and category assignment.
• The imaging analysis methodology varied across studies.
• The inter-reader reliability of CT LI-RADS differed significantly according to the average reader experience and the difference in reader experience. |
---|---|
ISSN: | 0938-7994 1432-1084 |
DOI: | 10.1007/s00330-021-07815-y |