Loading…

Factors Affecting Range of Motion After Revision Total Knee Arthroplasty

Range of motion (ROM) after revision total knee arthroplasty (RTKA) is an important clinical outcome, as decreased ROM can lead to patient dissatisfaction and diminished mobility. This study sought to determine the effect of type of revision, implant constraint level, and reason for revision has on...

Full description

Saved in:
Bibliographic Details
Published in:The Journal of arthroplasty 2021-09, Vol.36 (9), p.3259-3263
Main Authors: Lygrisse, Katherine A., Roof, Mackenzie A., Sharan, Mohamad, Teo, Greg, Long, William J., Schwarzkopf, Ran
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Range of motion (ROM) after revision total knee arthroplasty (RTKA) is an important clinical outcome, as decreased ROM can lead to patient dissatisfaction and diminished mobility. This study sought to determine the effect of type of revision, implant constraint level, and reason for revision has on RTKA ROM. A retrospective review of 832 RTKA cases from 2011 to 2019 was conducted at a single, urban academic institution. Patients who underwent aseptic RTKA and had preoperative and 1-year postoperative ROM in their chart were included. The ΔROM was calculated by subtracting the preoperative ROM from the 1-year postoperative ROM. ROM was compared between tibial polyethylene liner-only revisions (liner) and all other revision types (component) and based on reason for revision. Subanalysis was performed within the liner and component revision cohorts to determine the effect of reason for revision and implant constraint level on ROM. In total, 290 patients qualified. Forty-two patients had liner revisions (14.5%) and 248 had component revisions (85.5%). The ΔROM for component revision cases was significantly higher than liner exchange only (10° ± 24° vs.1° ± 19°; P = .03). ΔROM was not significant when comparing the level of implant constraint nor was it when separating and comparing by type of revision. Component revisions due to instability were found to significantly decrease ΔROM. Component revision cases have significantly improved ΔROM when compared with liner-only revision. Constraint level is not significantly associated with changes in ROM in either liner or component revisions. Component revisions due to instability significantly reduce ΔROM.
ISSN:0883-5403