Loading…
Aortic angle distribution and predictors of horizontal aorta in patients undergoing transcatheter aortic valve replacement
Horizontal aorta (HA) is an anatomical feature that can pose significant technical challenges for the successful positioning of the bioprosthetic valve during transcatheter aortic valve replacement (TAVR). Physiological range of aortic angle (AA) is unknown; hence there is no cutoff AA for classifyi...
Saved in:
Published in: | International journal of cardiology 2021-09, Vol.338, p.58-62 |
---|---|
Main Authors: | , , , , , , , , , , , , , , , , , , , , , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Horizontal aorta (HA) is an anatomical feature that can pose significant technical challenges for the successful positioning of the bioprosthetic valve during transcatheter aortic valve replacement (TAVR). Physiological range of aortic angle (AA) is unknown; hence there is no cutoff AA for classifying HA. Moreover, patient characteristics predicting HA are under-investigated.
This was a retrospective analysis of prospective collected data from 16 heart valve centers in Europe. The study utilized a common dataset with a priori agreed-upon definitions and variables. Eligible patients underwent TAVR between 2014 and 2020 and had multidetector computed tomographic imaging data available for determining the AA. The analysis described the distribution of AA and potential predictors of HA. Inter-center variability was also explored.
For 4022 patients analyzed, the mean AA ± standard deviation was 49.4° ± 9.4° (median 49°, inter-quartile range [IQR] 12°, range 18–90°). There was no significant difference in mean AA between men and women (49.4° ± 9.1° vs. 49.6° ± 9.3°, respectively; p = 0.53); therefore, 49.4° was accepted as the cutoff value for HA in subsequent analyses. Covariates significantly associated with HA included age (odds ratio [OR]: 1.02, 95% confidence interval [CI]: 1.01–1.04, p < 0.001), body mass index (OR: 1.06, 95% CI: 1.05–1.08, p < 0.01), previous cardiac surgery (OR: 0.58, 95% CI: 0.45–0.75, p < 0.001), and porcelain aorta (OR: 0.66, 95% CI: 0.52–0.85, p = 0.001). Some inter-center variability was observed.
We defined 49.4° as the mean AA, and also associated predictors of HA in a large case series of patients with severe aortic stenosis candidates for TAVR.
•What is the physiological aortic angle distribution in TAVR patients?•Mean aortic angle in a large series of TAVR patients with aortic stenosis was 49.4°.•Higher aortic angle values were observed in the elderly and in the obese. |
---|---|
ISSN: | 0167-5273 1874-1754 |