Loading…

Impact of myocardial injury and inflammation due to ablation on the short-term and mid-term outcomes: Cryoballoon versus laser balloon ablation

Cryoballoon ablation (CBA) and laser balloon ablation (LBA) were developed as alternatives to conventional radiofrequency ablation for paroxysmal atrial fibrillation (PAF). Pathological findings after ablation such as myocardial injury and inflammation are thought to be different between CBA and LBA...

Full description

Saved in:
Bibliographic Details
Published in:International journal of cardiology 2021-09, Vol.338, p.102-108
Main Authors: Yano, Masamichi, Egami, Yasuyuki, Ukita, Kohei, Kawamura, Akito, Nakamura, Hitoshi, Matsuhiro, Yutaka, Yasumoto, Koji, Tsuda, Masaki, Okamoto, Naotaka, Matsunaga-Lee, Yasuharu, Shutta, Ryu, Nishino, Masami, Tanouchi, Jun
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c428t-fde581b894f599e70a6b09f2dab3fccc2db591118599b06577848e5b0b2a0df03
cites cdi_FETCH-LOGICAL-c428t-fde581b894f599e70a6b09f2dab3fccc2db591118599b06577848e5b0b2a0df03
container_end_page 108
container_issue
container_start_page 102
container_title International journal of cardiology
container_volume 338
creator Yano, Masamichi
Egami, Yasuyuki
Ukita, Kohei
Kawamura, Akito
Nakamura, Hitoshi
Matsuhiro, Yutaka
Yasumoto, Koji
Tsuda, Masaki
Okamoto, Naotaka
Matsunaga-Lee, Yasuharu
Shutta, Ryu
Nishino, Masami
Tanouchi, Jun
description Cryoballoon ablation (CBA) and laser balloon ablation (LBA) were developed as alternatives to conventional radiofrequency ablation for paroxysmal atrial fibrillation (PAF). Pathological findings after ablation such as myocardial injury and inflammation are thought to be different between CBA and LBA. However, the different impact of myocardial injury and inflammation after ablation on short- and mid-term outcomes remains unclear. Consecutive PAF patients who underwent CBA and LBA were enrolled from the Osaka Rosai Atrial Fibrillation ablation (ORAF) registry. The difference of the acute myocardial injury marker (hs-TnI), and changes of inflammation markers (C reactive protein; ΔCRP, and white blood cell; ΔWBC) after catheter ablation and the difference of the short-term (within 3 months after ablation) and mid-term (from 3 months to 6 months after ablation) outcomes were evaluated between the two groups. The CBA and LBA groups consisted of 55 and 56 patients, respectively. After propensity score matching, CBA and LBA groups consisted of 37 patients, respectively. Hs-TnI value was significantly higher in CBA than LBA group, while ΔCRP and ΔWBC were significantly higher in LBA than CBA group. In the propensity score-matched pairs, the LBA group had a significantly greater risk of short-term arrhythmia recurrence than the CBA group, whereas no significant difference of mid-term arrhythmia recurrence were found between the two groups. Myocardial injury and inflammation status differ between CBA and LBA groups. LBA group had stronger inflammation after ablation and had a significantly greater risk of short-term arrhythmia recurrence after PVI than CBA group. •Myocardial injury and inflammation in cryo- and laser- balloon ablation.•Short-term and mid-term outcomes between cryo- and laser- balloon ablation.•Impact of pathological changes on outcomes between the different ablation methods.
doi_str_mv 10.1016/j.ijcard.2021.06.016
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2541321864</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S016752732100975X</els_id><sourcerecordid>2541321864</sourcerecordid><originalsourceid>FETCH-LOGICAL-c428t-fde581b894f599e70a6b09f2dab3fccc2db591118599b06577848e5b0b2a0df03</originalsourceid><addsrcrecordid>eNp9UctqHDEQFCEh3tj5gxB0zGXGkkbzyiEQFjs2GHKJz0KPHqxBGm0kjWG_Ir9sbcabY0DQ6lJVNa1C6BMlNSW0u55rO2sZTc0IozXp6gK-QTs69Lyifcvfol1B-qplfXOBPqQ0E0L4OA7v0UXDKetoQ3foz70_SJ1xmLA_hpOflQ7bZV7jEcvFlOvkpPcy27BgswLOAUvltr6c_AQ4PYWYqwzR_5V4a7YmrFkHD-kr3sdjUNK5UBTPENOasJMJIj6DZ8sr9G6SLsHH13qJHm9vfu3vqoefP-733x8qzdmQq8lAO1A1jHxqxxF6IjtFxokZqZpJa82MakdK6VBeFenavh_4AK0iikliJtJcoi-b7yGG3yukLLxNGpyTC4Q1CdZy2jA6dLxQ-UbVMaQUYRKHaL2MR0GJOEUhZrFFIU5RCNKJAhbZ59cJq_Jg_onOf18I3zYClD2fLUSRtIVFg7ERdBYm2P9PeAF4PZ8E</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2541321864</pqid></control><display><type>article</type><title>Impact of myocardial injury and inflammation due to ablation on the short-term and mid-term outcomes: Cryoballoon versus laser balloon ablation</title><source>ScienceDirect Freedom Collection</source><creator>Yano, Masamichi ; Egami, Yasuyuki ; Ukita, Kohei ; Kawamura, Akito ; Nakamura, Hitoshi ; Matsuhiro, Yutaka ; Yasumoto, Koji ; Tsuda, Masaki ; Okamoto, Naotaka ; Matsunaga-Lee, Yasuharu ; Shutta, Ryu ; Nishino, Masami ; Tanouchi, Jun</creator><creatorcontrib>Yano, Masamichi ; Egami, Yasuyuki ; Ukita, Kohei ; Kawamura, Akito ; Nakamura, Hitoshi ; Matsuhiro, Yutaka ; Yasumoto, Koji ; Tsuda, Masaki ; Okamoto, Naotaka ; Matsunaga-Lee, Yasuharu ; Shutta, Ryu ; Nishino, Masami ; Tanouchi, Jun</creatorcontrib><description>Cryoballoon ablation (CBA) and laser balloon ablation (LBA) were developed as alternatives to conventional radiofrequency ablation for paroxysmal atrial fibrillation (PAF). Pathological findings after ablation such as myocardial injury and inflammation are thought to be different between CBA and LBA. However, the different impact of myocardial injury and inflammation after ablation on short- and mid-term outcomes remains unclear. Consecutive PAF patients who underwent CBA and LBA were enrolled from the Osaka Rosai Atrial Fibrillation ablation (ORAF) registry. The difference of the acute myocardial injury marker (hs-TnI), and changes of inflammation markers (C reactive protein; ΔCRP, and white blood cell; ΔWBC) after catheter ablation and the difference of the short-term (within 3 months after ablation) and mid-term (from 3 months to 6 months after ablation) outcomes were evaluated between the two groups. The CBA and LBA groups consisted of 55 and 56 patients, respectively. After propensity score matching, CBA and LBA groups consisted of 37 patients, respectively. Hs-TnI value was significantly higher in CBA than LBA group, while ΔCRP and ΔWBC were significantly higher in LBA than CBA group. In the propensity score-matched pairs, the LBA group had a significantly greater risk of short-term arrhythmia recurrence than the CBA group, whereas no significant difference of mid-term arrhythmia recurrence were found between the two groups. Myocardial injury and inflammation status differ between CBA and LBA groups. LBA group had stronger inflammation after ablation and had a significantly greater risk of short-term arrhythmia recurrence after PVI than CBA group. •Myocardial injury and inflammation in cryo- and laser- balloon ablation.•Short-term and mid-term outcomes between cryo- and laser- balloon ablation.•Impact of pathological changes on outcomes between the different ablation methods.</description><identifier>ISSN: 0167-5273</identifier><identifier>EISSN: 1874-1754</identifier><identifier>DOI: 10.1016/j.ijcard.2021.06.016</identifier><identifier>PMID: 34126131</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Atrial Fibrillation - diagnosis ; Atrial Fibrillation - epidemiology ; Atrial Fibrillation - surgery ; Catheter Ablation - adverse effects ; Cryoballoon ablation ; Cryosurgery - adverse effects ; High-sensitive cardiac troponin I ; Humans ; Inflammation ; Inflammation - diagnosis ; Inflammation - epidemiology ; Inflammation - etiology ; Laser balloon ablation ; Lasers ; Myocardial injury ; Pulmonary Veins - surgery ; Recurrence ; Treatment Outcome</subject><ispartof>International journal of cardiology, 2021-09, Vol.338, p.102-108</ispartof><rights>2021 Elsevier B.V.</rights><rights>Copyright © 2021 Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c428t-fde581b894f599e70a6b09f2dab3fccc2db591118599b06577848e5b0b2a0df03</citedby><cites>FETCH-LOGICAL-c428t-fde581b894f599e70a6b09f2dab3fccc2db591118599b06577848e5b0b2a0df03</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/34126131$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Yano, Masamichi</creatorcontrib><creatorcontrib>Egami, Yasuyuki</creatorcontrib><creatorcontrib>Ukita, Kohei</creatorcontrib><creatorcontrib>Kawamura, Akito</creatorcontrib><creatorcontrib>Nakamura, Hitoshi</creatorcontrib><creatorcontrib>Matsuhiro, Yutaka</creatorcontrib><creatorcontrib>Yasumoto, Koji</creatorcontrib><creatorcontrib>Tsuda, Masaki</creatorcontrib><creatorcontrib>Okamoto, Naotaka</creatorcontrib><creatorcontrib>Matsunaga-Lee, Yasuharu</creatorcontrib><creatorcontrib>Shutta, Ryu</creatorcontrib><creatorcontrib>Nishino, Masami</creatorcontrib><creatorcontrib>Tanouchi, Jun</creatorcontrib><title>Impact of myocardial injury and inflammation due to ablation on the short-term and mid-term outcomes: Cryoballoon versus laser balloon ablation</title><title>International journal of cardiology</title><addtitle>Int J Cardiol</addtitle><description>Cryoballoon ablation (CBA) and laser balloon ablation (LBA) were developed as alternatives to conventional radiofrequency ablation for paroxysmal atrial fibrillation (PAF). Pathological findings after ablation such as myocardial injury and inflammation are thought to be different between CBA and LBA. However, the different impact of myocardial injury and inflammation after ablation on short- and mid-term outcomes remains unclear. Consecutive PAF patients who underwent CBA and LBA were enrolled from the Osaka Rosai Atrial Fibrillation ablation (ORAF) registry. The difference of the acute myocardial injury marker (hs-TnI), and changes of inflammation markers (C reactive protein; ΔCRP, and white blood cell; ΔWBC) after catheter ablation and the difference of the short-term (within 3 months after ablation) and mid-term (from 3 months to 6 months after ablation) outcomes were evaluated between the two groups. The CBA and LBA groups consisted of 55 and 56 patients, respectively. After propensity score matching, CBA and LBA groups consisted of 37 patients, respectively. Hs-TnI value was significantly higher in CBA than LBA group, while ΔCRP and ΔWBC were significantly higher in LBA than CBA group. In the propensity score-matched pairs, the LBA group had a significantly greater risk of short-term arrhythmia recurrence than the CBA group, whereas no significant difference of mid-term arrhythmia recurrence were found between the two groups. Myocardial injury and inflammation status differ between CBA and LBA groups. LBA group had stronger inflammation after ablation and had a significantly greater risk of short-term arrhythmia recurrence after PVI than CBA group. •Myocardial injury and inflammation in cryo- and laser- balloon ablation.•Short-term and mid-term outcomes between cryo- and laser- balloon ablation.•Impact of pathological changes on outcomes between the different ablation methods.</description><subject>Atrial Fibrillation - diagnosis</subject><subject>Atrial Fibrillation - epidemiology</subject><subject>Atrial Fibrillation - surgery</subject><subject>Catheter Ablation - adverse effects</subject><subject>Cryoballoon ablation</subject><subject>Cryosurgery - adverse effects</subject><subject>High-sensitive cardiac troponin I</subject><subject>Humans</subject><subject>Inflammation</subject><subject>Inflammation - diagnosis</subject><subject>Inflammation - epidemiology</subject><subject>Inflammation - etiology</subject><subject>Laser balloon ablation</subject><subject>Lasers</subject><subject>Myocardial injury</subject><subject>Pulmonary Veins - surgery</subject><subject>Recurrence</subject><subject>Treatment Outcome</subject><issn>0167-5273</issn><issn>1874-1754</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNp9UctqHDEQFCEh3tj5gxB0zGXGkkbzyiEQFjs2GHKJz0KPHqxBGm0kjWG_Ir9sbcabY0DQ6lJVNa1C6BMlNSW0u55rO2sZTc0IozXp6gK-QTs69Lyifcvfol1B-qplfXOBPqQ0E0L4OA7v0UXDKetoQ3foz70_SJ1xmLA_hpOflQ7bZV7jEcvFlOvkpPcy27BgswLOAUvltr6c_AQ4PYWYqwzR_5V4a7YmrFkHD-kr3sdjUNK5UBTPENOasJMJIj6DZ8sr9G6SLsHH13qJHm9vfu3vqoefP-733x8qzdmQq8lAO1A1jHxqxxF6IjtFxokZqZpJa82MakdK6VBeFenavh_4AK0iikliJtJcoi-b7yGG3yukLLxNGpyTC4Q1CdZy2jA6dLxQ-UbVMaQUYRKHaL2MR0GJOEUhZrFFIU5RCNKJAhbZ59cJq_Jg_onOf18I3zYClD2fLUSRtIVFg7ERdBYm2P9PeAF4PZ8E</recordid><startdate>20210901</startdate><enddate>20210901</enddate><creator>Yano, Masamichi</creator><creator>Egami, Yasuyuki</creator><creator>Ukita, Kohei</creator><creator>Kawamura, Akito</creator><creator>Nakamura, Hitoshi</creator><creator>Matsuhiro, Yutaka</creator><creator>Yasumoto, Koji</creator><creator>Tsuda, Masaki</creator><creator>Okamoto, Naotaka</creator><creator>Matsunaga-Lee, Yasuharu</creator><creator>Shutta, Ryu</creator><creator>Nishino, Masami</creator><creator>Tanouchi, Jun</creator><general>Elsevier B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20210901</creationdate><title>Impact of myocardial injury and inflammation due to ablation on the short-term and mid-term outcomes: Cryoballoon versus laser balloon ablation</title><author>Yano, Masamichi ; Egami, Yasuyuki ; Ukita, Kohei ; Kawamura, Akito ; Nakamura, Hitoshi ; Matsuhiro, Yutaka ; Yasumoto, Koji ; Tsuda, Masaki ; Okamoto, Naotaka ; Matsunaga-Lee, Yasuharu ; Shutta, Ryu ; Nishino, Masami ; Tanouchi, Jun</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c428t-fde581b894f599e70a6b09f2dab3fccc2db591118599b06577848e5b0b2a0df03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Atrial Fibrillation - diagnosis</topic><topic>Atrial Fibrillation - epidemiology</topic><topic>Atrial Fibrillation - surgery</topic><topic>Catheter Ablation - adverse effects</topic><topic>Cryoballoon ablation</topic><topic>Cryosurgery - adverse effects</topic><topic>High-sensitive cardiac troponin I</topic><topic>Humans</topic><topic>Inflammation</topic><topic>Inflammation - diagnosis</topic><topic>Inflammation - epidemiology</topic><topic>Inflammation - etiology</topic><topic>Laser balloon ablation</topic><topic>Lasers</topic><topic>Myocardial injury</topic><topic>Pulmonary Veins - surgery</topic><topic>Recurrence</topic><topic>Treatment Outcome</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yano, Masamichi</creatorcontrib><creatorcontrib>Egami, Yasuyuki</creatorcontrib><creatorcontrib>Ukita, Kohei</creatorcontrib><creatorcontrib>Kawamura, Akito</creatorcontrib><creatorcontrib>Nakamura, Hitoshi</creatorcontrib><creatorcontrib>Matsuhiro, Yutaka</creatorcontrib><creatorcontrib>Yasumoto, Koji</creatorcontrib><creatorcontrib>Tsuda, Masaki</creatorcontrib><creatorcontrib>Okamoto, Naotaka</creatorcontrib><creatorcontrib>Matsunaga-Lee, Yasuharu</creatorcontrib><creatorcontrib>Shutta, Ryu</creatorcontrib><creatorcontrib>Nishino, Masami</creatorcontrib><creatorcontrib>Tanouchi, Jun</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>International journal of cardiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yano, Masamichi</au><au>Egami, Yasuyuki</au><au>Ukita, Kohei</au><au>Kawamura, Akito</au><au>Nakamura, Hitoshi</au><au>Matsuhiro, Yutaka</au><au>Yasumoto, Koji</au><au>Tsuda, Masaki</au><au>Okamoto, Naotaka</au><au>Matsunaga-Lee, Yasuharu</au><au>Shutta, Ryu</au><au>Nishino, Masami</au><au>Tanouchi, Jun</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Impact of myocardial injury and inflammation due to ablation on the short-term and mid-term outcomes: Cryoballoon versus laser balloon ablation</atitle><jtitle>International journal of cardiology</jtitle><addtitle>Int J Cardiol</addtitle><date>2021-09-01</date><risdate>2021</risdate><volume>338</volume><spage>102</spage><epage>108</epage><pages>102-108</pages><issn>0167-5273</issn><eissn>1874-1754</eissn><abstract>Cryoballoon ablation (CBA) and laser balloon ablation (LBA) were developed as alternatives to conventional radiofrequency ablation for paroxysmal atrial fibrillation (PAF). Pathological findings after ablation such as myocardial injury and inflammation are thought to be different between CBA and LBA. However, the different impact of myocardial injury and inflammation after ablation on short- and mid-term outcomes remains unclear. Consecutive PAF patients who underwent CBA and LBA were enrolled from the Osaka Rosai Atrial Fibrillation ablation (ORAF) registry. The difference of the acute myocardial injury marker (hs-TnI), and changes of inflammation markers (C reactive protein; ΔCRP, and white blood cell; ΔWBC) after catheter ablation and the difference of the short-term (within 3 months after ablation) and mid-term (from 3 months to 6 months after ablation) outcomes were evaluated between the two groups. The CBA and LBA groups consisted of 55 and 56 patients, respectively. After propensity score matching, CBA and LBA groups consisted of 37 patients, respectively. Hs-TnI value was significantly higher in CBA than LBA group, while ΔCRP and ΔWBC were significantly higher in LBA than CBA group. In the propensity score-matched pairs, the LBA group had a significantly greater risk of short-term arrhythmia recurrence than the CBA group, whereas no significant difference of mid-term arrhythmia recurrence were found between the two groups. Myocardial injury and inflammation status differ between CBA and LBA groups. LBA group had stronger inflammation after ablation and had a significantly greater risk of short-term arrhythmia recurrence after PVI than CBA group. •Myocardial injury and inflammation in cryo- and laser- balloon ablation.•Short-term and mid-term outcomes between cryo- and laser- balloon ablation.•Impact of pathological changes on outcomes between the different ablation methods.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>34126131</pmid><doi>10.1016/j.ijcard.2021.06.016</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0167-5273
ispartof International journal of cardiology, 2021-09, Vol.338, p.102-108
issn 0167-5273
1874-1754
language eng
recordid cdi_proquest_miscellaneous_2541321864
source ScienceDirect Freedom Collection
subjects Atrial Fibrillation - diagnosis
Atrial Fibrillation - epidemiology
Atrial Fibrillation - surgery
Catheter Ablation - adverse effects
Cryoballoon ablation
Cryosurgery - adverse effects
High-sensitive cardiac troponin I
Humans
Inflammation
Inflammation - diagnosis
Inflammation - epidemiology
Inflammation - etiology
Laser balloon ablation
Lasers
Myocardial injury
Pulmonary Veins - surgery
Recurrence
Treatment Outcome
title Impact of myocardial injury and inflammation due to ablation on the short-term and mid-term outcomes: Cryoballoon versus laser balloon ablation
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T23%3A24%3A05IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Impact%20of%20myocardial%20injury%20and%20inflammation%20due%20to%20ablation%20on%20the%20short-term%20and%20mid-term%20outcomes:%20Cryoballoon%20versus%20laser%20balloon%20ablation&rft.jtitle=International%20journal%20of%20cardiology&rft.au=Yano,%20Masamichi&rft.date=2021-09-01&rft.volume=338&rft.spage=102&rft.epage=108&rft.pages=102-108&rft.issn=0167-5273&rft.eissn=1874-1754&rft_id=info:doi/10.1016/j.ijcard.2021.06.016&rft_dat=%3Cproquest_cross%3E2541321864%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c428t-fde581b894f599e70a6b09f2dab3fccc2db591118599b06577848e5b0b2a0df03%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2541321864&rft_id=info:pmid/34126131&rfr_iscdi=true