Effect of different driver power amplitudes on liver stiffness measurement in pediatric liver MR elastography

Purpose To assess how different driver power amplitudes affect the measurement of liver stiffness in pediatric liver magnetic resonance elastography (MRE). Methods From January 2018 to May 2018, pediatric patients (≤ 18 years) who underwent liver MRE with 20% and 56% driver power amplitudes were inc...

Full description

Saved in:
Bibliographic Details
Published in:Abdominal imaging 2021-10, Vol.46 (10), p.4729-4735
Main Authors: Kim, Dong-Kyu, Yoon, Haesung, Han, Kyunghwa, Kim, Jisoo, Lee, Mi-Jung, Kim, Seung, Koh, Hong, Han, Seok Joo, Shin, Hyun Joo
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Purpose To assess how different driver power amplitudes affect the measurement of liver stiffness in pediatric liver magnetic resonance elastography (MRE). Methods From January 2018 to May 2018, pediatric patients (≤ 18 years) who underwent liver MRE with 20% and 56% driver power amplitudes were included in this retrospective study. Region-of-interests (ROIs) were drawn on four stiffness maps to include the largest area of the liver parenchyma. Intraclass correlation coefficients (ICCs) were used to assess agreements for the area, mean, maximum, minimum and standard deviation of liver stiffness between the driver power amplitudes. Results 128 MRE stiffness maps from 16 patients (M:F = 10:6, median 12.5 years old) were included. On MRE, median ROI areas of liver were 83.1 cm 2 (range, 46.9–144.1 cm 2 ) and 63.0 cm 2 (range, 5.4–123.4 cm 2 ) for the driver power amplitudes of 20% and 56%, respectively. Median liver stiffness values were 2.3 kPa (range, 1.7–8.0 kPa) and 2.8 kPa (range, 1.7–8.5 kPa). Maximum and minimum liver stiffness values were 5.3 kPa and 1.0 kPa for 20% and 7.8 kPa and 1.1 kPa for 56%. Standard deviation was 0.6 kPa for 20% and 1.0 kPa for 56%. ICC values between the two power amplitudes were 0.33–0.51 for the ROI area and the maximum, minimum and standard deviation values of liver stiffness. The ICC value for liver stiffness was 0.857 (95% confidence interval, 0.760–0.915). Conclusion Liver stiffness with two driver power amplitudes on MRE showed good reliability in pediatric patients. Driver power amplitudes need to be optimized according to the pediatric liver size.
ISSN:2366-004X
2366-0058
DOI:10.1007/s00261-021-03197-3