This study sought to evaluate the effects of right ventricular (RV) pacing versus biventricular (BiV) pacing on quality of life, functional status, and arrhythmias in LVAD patients. Cardiac resynchronization therapy (CRT) and left ventricular assist devices (LVADs) independently improve outcomes in...

Full description

Saved in:
Bibliographic Details
Published in:JACC. Clinical electrophysiology 2021-08, Vol.7 (8), p.1003-1009
Main Authors: Chung, Ben B., Grinstein, Jonathan S., Imamura, Teruhiko, Kruse, Eric, Nguyen, Ann B., Narang, Nikhil, Holzhauser, Luise H., Burkhoff, Daniel, Lang, Roberto M., Sayer, Gabriel T., Uriel, Nir Y.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c266t-d74135505a2f1b077b5c272dab1832b98afc1b3412899313a1b13d6c3fcc26c93
cites cdi_FETCH-LOGICAL-c266t-d74135505a2f1b077b5c272dab1832b98afc1b3412899313a1b13d6c3fcc26c93
container_end_page 1009
container_issue 8
container_start_page 1003
container_title JACC. Clinical electrophysiology
container_volume 7
creator Chung, Ben B.
Grinstein, Jonathan S.
Imamura, Teruhiko
Kruse, Eric
Nguyen, Ann B.
Narang, Nikhil
Holzhauser, Luise H.
Burkhoff, Daniel
Lang, Roberto M.
Sayer, Gabriel T.
Uriel, Nir Y.
description This study sought to evaluate the effects of right ventricular (RV) pacing versus biventricular (BiV) pacing on quality of life, functional status, and arrhythmias in LVAD patients. Cardiac resynchronization therapy (CRT) and left ventricular assist devices (LVADs) independently improve outcomes in heart failure patients, but the effects of combining these therapies remains unknown. We present the first prospective randomized study evaluating the effects of RV versus BiV pacing on quality of life, functional status, and arrhythmias in LVAD patients. In this prospective randomized crossover study, LVAD patients with prior CRT devices were alternated on RV and BiV pacing for planned 7–14-day periods. Ambulatory step count, 6-minute walk test distance, Kansas City Cardiomyopathy Questionnaire scores, arrhythmia burden, CRT lead function, and echocardiographic data were collected with each pacing mode. Thirty patients were enrolled, with a median age of 65 years, 67% male, and mean duration of LVAD support of 309 days. Compared with BiV pacing, RV-only pacing resulted in 29% higher mean daily step count, 11% higher 6-minute walk test distance, and 7% improved KCCQ-12 score (all p 
doi_str_mv 10.1016/j.jacep.2021.01.016
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2548602578</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S2405500X21001079</els_id><sourcerecordid>2548602578</sourcerecordid><originalsourceid>FETCH-LOGICAL-c266t-d74135505a2f1b077b5c272dab1832b98afc1b3412899313a1b13d6c3fcc26c93</originalsourceid><addsrcrecordid>eNp9UM1Kw0AYXETBUvsEXnL0krjfbjY_Bw-1WhUKitrqbdlsNu2GNIm7m4Jv47P4ZCZWvAjCwDfwzQzMIHQKOAAM0XkZlEKqNiCYQIAHRAdoRELMfIYhOfzl-PUYTawtMcbASEIgHKHlpd6p2hktu0oY70FIXa-9lTK2s96jXm_c58fqr0DXPXO6f1jvqWvbxjiVey_abbzFanp1go4KUVk1-bljtJxfP89u_cX9zd1suvAliSLn53EIlDHMBCkgw3GcMUlikosMEkqyNBGFhIyGQJI0pUAFZEDzSNJC9gEypWN0ts9tTfPWKev4VlupqkrUquksJyxMIkxYnPRSupdK01hrVMFbo7fCvHPAfNiRl_x7Rz7syPGAqHdd7F2qb7HTynAr-9ZS5doo6Xje6H_9X_zRfJ8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2548602578</pqid></control><display><type>article</type><title>Biventricular Pacing Versus Right Ventricular Pacing in Patients Supported With LVAD</title><source>ScienceDirect</source><creator>Chung, Ben B. ; Grinstein, Jonathan S. ; Imamura, Teruhiko ; Kruse, Eric ; Nguyen, Ann B. ; Narang, Nikhil ; Holzhauser, Luise H. ; Burkhoff, Daniel ; Lang, Roberto M. ; Sayer, Gabriel T. ; Uriel, Nir Y.</creator><creatorcontrib>Chung, Ben B. ; Grinstein, Jonathan S. ; Imamura, Teruhiko ; Kruse, Eric ; Nguyen, Ann B. ; Narang, Nikhil ; Holzhauser, Luise H. ; Burkhoff, Daniel ; Lang, Roberto M. ; Sayer, Gabriel T. ; Uriel, Nir Y.</creatorcontrib><description>This study sought to evaluate the effects of right ventricular (RV) pacing versus biventricular (BiV) pacing on quality of life, functional status, and arrhythmias in LVAD patients. Cardiac resynchronization therapy (CRT) and left ventricular assist devices (LVADs) independently improve outcomes in heart failure patients, but the effects of combining these therapies remains unknown. We present the first prospective randomized study evaluating the effects of RV versus BiV pacing on quality of life, functional status, and arrhythmias in LVAD patients. In this prospective randomized crossover study, LVAD patients with prior CRT devices were alternated on RV and BiV pacing for planned 7–14-day periods. Ambulatory step count, 6-minute walk test distance, Kansas City Cardiomyopathy Questionnaire scores, arrhythmia burden, CRT lead function, and echocardiographic data were collected with each pacing mode. Thirty patients were enrolled, with a median age of 65 years, 67% male, and mean duration of LVAD support of 309 days. Compared with BiV pacing, RV-only pacing resulted in 29% higher mean daily step count, 11% higher 6-minute walk test distance, and 7% improved KCCQ-12 score (all p &lt; 0.03). LV end-diastolic volume was significantly lower with RV pacing (220 vs. 250 mL; p = 0.03). Fewer patients had ventricular tachyarrhythmia episodes during RV pacing (p = 0.03). RV lead impedance was lower with RV pacing (p = 0.047), but no significant differences were observed in impedance across other CRT leads. In the first prospective randomized study comparing variable pacing in LVAD patients, RV pacing was associated with significantly improved functional status, quality of life, fewer ventricular tachyarrhythmias, and stable lead impedance compared with BiV pacing. This study supports turning off LV lead pacing in LVAD patients with CRT. [Display omitted]</description><identifier>ISSN: 2405-500X</identifier><identifier>EISSN: 2405-5018</identifier><identifier>DOI: 10.1016/j.jacep.2021.01.016</identifier><language>eng</language><publisher>Elsevier Inc</publisher><subject>biventricular pacing ; cardiac resynchronization ; CRT ; left ventricular assist device ; LVAD ; VAD</subject><ispartof>JACC. Clinical electrophysiology, 2021-08, Vol.7 (8), p.1003-1009</ispartof><rights>2021 American College of Cardiology Foundation</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c266t-d74135505a2f1b077b5c272dab1832b98afc1b3412899313a1b13d6c3fcc26c93</citedby><cites>FETCH-LOGICAL-c266t-d74135505a2f1b077b5c272dab1832b98afc1b3412899313a1b13d6c3fcc26c93</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S2405500X21001079$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3549,27924,27925,45780</link.rule.ids></links><search><creatorcontrib>Chung, Ben B.</creatorcontrib><creatorcontrib>Grinstein, Jonathan S.</creatorcontrib><creatorcontrib>Imamura, Teruhiko</creatorcontrib><creatorcontrib>Kruse, Eric</creatorcontrib><creatorcontrib>Nguyen, Ann B.</creatorcontrib><creatorcontrib>Narang, Nikhil</creatorcontrib><creatorcontrib>Holzhauser, Luise H.</creatorcontrib><creatorcontrib>Burkhoff, Daniel</creatorcontrib><creatorcontrib>Lang, Roberto M.</creatorcontrib><creatorcontrib>Sayer, Gabriel T.</creatorcontrib><creatorcontrib>Uriel, Nir Y.</creatorcontrib><title>Biventricular Pacing Versus Right Ventricular Pacing in Patients Supported With LVAD</title><title>JACC. Clinical electrophysiology</title><description>This study sought to evaluate the effects of right ventricular (RV) pacing versus biventricular (BiV) pacing on quality of life, functional status, and arrhythmias in LVAD patients. Cardiac resynchronization therapy (CRT) and left ventricular assist devices (LVADs) independently improve outcomes in heart failure patients, but the effects of combining these therapies remains unknown. We present the first prospective randomized study evaluating the effects of RV versus BiV pacing on quality of life, functional status, and arrhythmias in LVAD patients. In this prospective randomized crossover study, LVAD patients with prior CRT devices were alternated on RV and BiV pacing for planned 7–14-day periods. Ambulatory step count, 6-minute walk test distance, Kansas City Cardiomyopathy Questionnaire scores, arrhythmia burden, CRT lead function, and echocardiographic data were collected with each pacing mode. Thirty patients were enrolled, with a median age of 65 years, 67% male, and mean duration of LVAD support of 309 days. Compared with BiV pacing, RV-only pacing resulted in 29% higher mean daily step count, 11% higher 6-minute walk test distance, and 7% improved KCCQ-12 score (all p &lt; 0.03). LV end-diastolic volume was significantly lower with RV pacing (220 vs. 250 mL; p = 0.03). Fewer patients had ventricular tachyarrhythmia episodes during RV pacing (p = 0.03). RV lead impedance was lower with RV pacing (p = 0.047), but no significant differences were observed in impedance across other CRT leads. In the first prospective randomized study comparing variable pacing in LVAD patients, RV pacing was associated with significantly improved functional status, quality of life, fewer ventricular tachyarrhythmias, and stable lead impedance compared with BiV pacing. This study supports turning off LV lead pacing in LVAD patients with CRT. [Display omitted]</description><subject>biventricular pacing</subject><subject>cardiac resynchronization</subject><subject>CRT</subject><subject>left ventricular assist device</subject><subject>LVAD</subject><subject>VAD</subject><issn>2405-500X</issn><issn>2405-5018</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNp9UM1Kw0AYXETBUvsEXnL0krjfbjY_Bw-1WhUKitrqbdlsNu2GNIm7m4Jv47P4ZCZWvAjCwDfwzQzMIHQKOAAM0XkZlEKqNiCYQIAHRAdoRELMfIYhOfzl-PUYTawtMcbASEIgHKHlpd6p2hktu0oY70FIXa-9lTK2s96jXm_c58fqr0DXPXO6f1jvqWvbxjiVey_abbzFanp1go4KUVk1-bljtJxfP89u_cX9zd1suvAliSLn53EIlDHMBCkgw3GcMUlikosMEkqyNBGFhIyGQJI0pUAFZEDzSNJC9gEypWN0ts9tTfPWKev4VlupqkrUquksJyxMIkxYnPRSupdK01hrVMFbo7fCvHPAfNiRl_x7Rz7syPGAqHdd7F2qb7HTynAr-9ZS5doo6Xje6H_9X_zRfJ8</recordid><startdate>202108</startdate><enddate>202108</enddate><creator>Chung, Ben B.</creator><creator>Grinstein, Jonathan S.</creator><creator>Imamura, Teruhiko</creator><creator>Kruse, Eric</creator><creator>Nguyen, Ann B.</creator><creator>Narang, Nikhil</creator><creator>Holzhauser, Luise H.</creator><creator>Burkhoff, Daniel</creator><creator>Lang, Roberto M.</creator><creator>Sayer, Gabriel T.</creator><creator>Uriel, Nir Y.</creator><general>Elsevier Inc</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>202108</creationdate><title>Biventricular Pacing Versus Right Ventricular Pacing in Patients Supported With LVAD</title><author>Chung, Ben B. ; Grinstein, Jonathan S. ; Imamura, Teruhiko ; Kruse, Eric ; Nguyen, Ann B. ; Narang, Nikhil ; Holzhauser, Luise H. ; Burkhoff, Daniel ; Lang, Roberto M. ; Sayer, Gabriel T. ; Uriel, Nir Y.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c266t-d74135505a2f1b077b5c272dab1832b98afc1b3412899313a1b13d6c3fcc26c93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>biventricular pacing</topic><topic>cardiac resynchronization</topic><topic>CRT</topic><topic>left ventricular assist device</topic><topic>LVAD</topic><topic>VAD</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Chung, Ben B.</creatorcontrib><creatorcontrib>Grinstein, Jonathan S.</creatorcontrib><creatorcontrib>Imamura, Teruhiko</creatorcontrib><creatorcontrib>Kruse, Eric</creatorcontrib><creatorcontrib>Nguyen, Ann B.</creatorcontrib><creatorcontrib>Narang, Nikhil</creatorcontrib><creatorcontrib>Holzhauser, Luise H.</creatorcontrib><creatorcontrib>Burkhoff, Daniel</creatorcontrib><creatorcontrib>Lang, Roberto M.</creatorcontrib><creatorcontrib>Sayer, Gabriel T.</creatorcontrib><creatorcontrib>Uriel, Nir Y.</creatorcontrib><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>JACC. Clinical electrophysiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Chung, Ben B.</au><au>Grinstein, Jonathan S.</au><au>Imamura, Teruhiko</au><au>Kruse, Eric</au><au>Nguyen, Ann B.</au><au>Narang, Nikhil</au><au>Holzhauser, Luise H.</au><au>Burkhoff, Daniel</au><au>Lang, Roberto M.</au><au>Sayer, Gabriel T.</au><au>Uriel, Nir Y.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Biventricular Pacing Versus Right Ventricular Pacing in Patients Supported With LVAD</atitle><jtitle>JACC. Clinical electrophysiology</jtitle><date>2021-08</date><risdate>2021</risdate><volume>7</volume><issue>8</issue><spage>1003</spage><epage>1009</epage><pages>1003-1009</pages><issn>2405-500X</issn><eissn>2405-5018</eissn><abstract>This study sought to evaluate the effects of right ventricular (RV) pacing versus biventricular (BiV) pacing on quality of life, functional status, and arrhythmias in LVAD patients. Cardiac resynchronization therapy (CRT) and left ventricular assist devices (LVADs) independently improve outcomes in heart failure patients, but the effects of combining these therapies remains unknown. We present the first prospective randomized study evaluating the effects of RV versus BiV pacing on quality of life, functional status, and arrhythmias in LVAD patients. In this prospective randomized crossover study, LVAD patients with prior CRT devices were alternated on RV and BiV pacing for planned 7–14-day periods. Ambulatory step count, 6-minute walk test distance, Kansas City Cardiomyopathy Questionnaire scores, arrhythmia burden, CRT lead function, and echocardiographic data were collected with each pacing mode. Thirty patients were enrolled, with a median age of 65 years, 67% male, and mean duration of LVAD support of 309 days. Compared with BiV pacing, RV-only pacing resulted in 29% higher mean daily step count, 11% higher 6-minute walk test distance, and 7% improved KCCQ-12 score (all p &lt; 0.03). LV end-diastolic volume was significantly lower with RV pacing (220 vs. 250 mL; p = 0.03). Fewer patients had ventricular tachyarrhythmia episodes during RV pacing (p = 0.03). RV lead impedance was lower with RV pacing (p = 0.047), but no significant differences were observed in impedance across other CRT leads. In the first prospective randomized study comparing variable pacing in LVAD patients, RV pacing was associated with significantly improved functional status, quality of life, fewer ventricular tachyarrhythmias, and stable lead impedance compared with BiV pacing. This study supports turning off LV lead pacing in LVAD patients with CRT. [Display omitted]</abstract><pub>Elsevier Inc</pub><doi>10.1016/j.jacep.2021.01.016</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 2405-500X
ispartof JACC. Clinical electrophysiology, 2021-08, Vol.7 (8), p.1003-1009
issn 2405-500X
2405-5018
language eng
recordid cdi_proquest_miscellaneous_2548602578
source ScienceDirect
subjects biventricular pacing
cardiac resynchronization
CRT
left ventricular assist device
LVAD
VAD
title Biventricular Pacing Versus Right Ventricular Pacing in Patients Supported With LVAD
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-30T19%3A29%3A18IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Biventricular%20Pacing%20Versus%20Right%C2%A0Ventricular%20Pacing%20in%20Patients%20Supported%20With%20LVAD&rft.jtitle=JACC.%20Clinical%20electrophysiology&rft.au=Chung,%20Ben%20B.&rft.date=2021-08&rft.volume=7&rft.issue=8&rft.spage=1003&rft.epage=1009&rft.pages=1003-1009&rft.issn=2405-500X&rft.eissn=2405-5018&rft_id=info:doi/10.1016/j.jacep.2021.01.016&rft_dat=%3Cproquest_cross%3E2548602578%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c266t-d74135505a2f1b077b5c272dab1832b98afc1b3412899313a1b13d6c3fcc26c93%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2548602578&rft_id=info:pmid/&rfr_iscdi=true