Loading…
Evaluation of the Diagnostic Performance of Swept-Source Anterior Segment Optical Coherence Tomography in Primary Angle Closure Disease
To evaluate the diagnostic performance of swept-source anterior segment optical coherence tomography (SS-OCT) in differentiating eyes with primary angle closure disease (PACD) from eyes of control subjects, as well as eyes with PAC and PAC glaucoma (PACG) from eyes with PAC suspect (PACS) disease. M...
Saved in:
Published in: | American journal of ophthalmology 2022-01, Vol.233, p.68-77 |
---|---|
Main Authors: | , , , , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c381t-5a11721baddc21c161164ef30ed5793ffdae54f82f8f2b35c283b5d71e1b1773 |
---|---|
cites | cdi_FETCH-LOGICAL-c381t-5a11721baddc21c161164ef30ed5793ffdae54f82f8f2b35c283b5d71e1b1773 |
container_end_page | 77 |
container_issue | |
container_start_page | 68 |
container_title | American journal of ophthalmology |
container_volume | 233 |
creator | Ma, Ping Wu, Yanyan Oatts, Julius Patlidanon, Jutima Yu, Yinxi Ying, Gui-Shuang Kline, Brad Tun, Tin A. He, Mingguang Aung, Tin Li, Shuning Yang, Yangfan Han, Ying |
description | To evaluate the diagnostic performance of swept-source anterior segment optical coherence tomography (SS-OCT) in differentiating eyes with primary angle closure disease (PACD) from eyes of control subjects, as well as eyes with PAC and PAC glaucoma (PACG) from eyes with PAC suspect (PACS) disease.
Multicenter cross-sectional study.
Chinese patients were classified into control, PACS, and PAC/PACG groups. The area under the receiving operating characteristic curve (AUC) from logistic regression models was used to evaluate discriminating ability. Sensitivity and specificity were calculated, and performance of the models was validated using an independent dataset.
A total of 2928 SS-OCT images from 366 eyes of 260 patients were recruited to develop diagnostic models. The validation dataset included 1176 SS-OCT images from 147 eyes of 143 patients. For distinguishing PACD from control eyes, average anterior chamber depth had the highest AUC (0.94). With a cutoff of 2.2 mm for average anterior chamber depth, the sensitivity and specificity were 90.2% and 85.2% in the training set. For distinguishing PAC/PACG from PACS, a multivariate model had an AUC of 0.83, with sensitivity and specificity of 82.0% and 62.8% in the training set. The validation set confirmed the findings.
SS-OCT of the anterior segment showed excellent diagnostic performance distinguishing PACD from normal eyes and moderate diagnostic ability distinguishing eyes with PAC/PACG from eyes with PACS. ACD alone may provide a simple and effective way to diagnose PACD from control subjects. As ACD can be obtained using other more available modalities, this has implications for the early diagnosis of PACD. |
doi_str_mv | 10.1016/j.ajo.2021.06.033 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2553821259</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0002939421003627</els_id><sourcerecordid>2553821259</sourcerecordid><originalsourceid>FETCH-LOGICAL-c381t-5a11721baddc21c161164ef30ed5793ffdae54f82f8f2b35c283b5d71e1b1773</originalsourceid><addsrcrecordid>eNp9kc1u1DAUhS1ERYe2D8AGWWLDJqmvnV-xqoYWkCq10szecpzrGUdJHOykqE_Aa9fRFBYsWFlX_s6xzz2EfACWAoPiuktV51LOOKSsSJkQb8gGqrJOoKrhLdkwxnhSizo7J-9D6OJYlFn5jpyLjFeiLrMN-X37pPpFzdaN1Bk6H5F-teowujBbTR_RG-cHNWpcb3e_cJqTnVt8nG_GGb11nu7wMOA404cpSlRPt-6IHlfJ3g3u4NV0fKZ2pI_eDso_R-GhR7rtXVj8-lpAFfCSnBnVB7x6PS_I_u52v_2e3D98-7G9uU-0qGBOcgVQcmhU22oOGgqAIkMjGLZ5WQtjWoV5ZipuKsMbkeuYs8nbEhAaKEtxQT6fbCfvfi4YZjnYoLHv1YhuCZLnuag48LyO6Kd_0C4GH-PnJC9YzaosF6shnCjtXQgejZxOMSUwuZYkOxlLkmtJkhUylhQ1H1-dl2bA9q_iTysR-HICMG7iyaKXQdt1o631qGfZOvsf-xe1NKNI</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2609084537</pqid></control><display><type>article</type><title>Evaluation of the Diagnostic Performance of Swept-Source Anterior Segment Optical Coherence Tomography in Primary Angle Closure Disease</title><source>Elsevier</source><creator>Ma, Ping ; Wu, Yanyan ; Oatts, Julius ; Patlidanon, Jutima ; Yu, Yinxi ; Ying, Gui-Shuang ; Kline, Brad ; Tun, Tin A. ; He, Mingguang ; Aung, Tin ; Li, Shuning ; Yang, Yangfan ; Han, Ying</creator><creatorcontrib>Ma, Ping ; Wu, Yanyan ; Oatts, Julius ; Patlidanon, Jutima ; Yu, Yinxi ; Ying, Gui-Shuang ; Kline, Brad ; Tun, Tin A. ; He, Mingguang ; Aung, Tin ; Li, Shuning ; Yang, Yangfan ; Han, Ying</creatorcontrib><description>To evaluate the diagnostic performance of swept-source anterior segment optical coherence tomography (SS-OCT) in differentiating eyes with primary angle closure disease (PACD) from eyes of control subjects, as well as eyes with PAC and PAC glaucoma (PACG) from eyes with PAC suspect (PACS) disease.
Multicenter cross-sectional study.
Chinese patients were classified into control, PACS, and PAC/PACG groups. The area under the receiving operating characteristic curve (AUC) from logistic regression models was used to evaluate discriminating ability. Sensitivity and specificity were calculated, and performance of the models was validated using an independent dataset.
A total of 2928 SS-OCT images from 366 eyes of 260 patients were recruited to develop diagnostic models. The validation dataset included 1176 SS-OCT images from 147 eyes of 143 patients. For distinguishing PACD from control eyes, average anterior chamber depth had the highest AUC (0.94). With a cutoff of 2.2 mm for average anterior chamber depth, the sensitivity and specificity were 90.2% and 85.2% in the training set. For distinguishing PAC/PACG from PACS, a multivariate model had an AUC of 0.83, with sensitivity and specificity of 82.0% and 62.8% in the training set. The validation set confirmed the findings.
SS-OCT of the anterior segment showed excellent diagnostic performance distinguishing PACD from normal eyes and moderate diagnostic ability distinguishing eyes with PAC/PACG from eyes with PACS. ACD alone may provide a simple and effective way to diagnose PACD from control subjects. As ACD can be obtained using other more available modalities, this has implications for the early diagnosis of PACD.</description><identifier>ISSN: 0002-9394</identifier><identifier>EISSN: 1879-1891</identifier><identifier>DOI: 10.1016/j.ajo.2021.06.033</identifier><identifier>PMID: 34283974</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Anterior Eye Segment - diagnostic imaging ; Cataracts ; Cross-Sectional Studies ; Datasets ; Disease ; Generalized linear models ; Glaucoma ; Glaucoma, Angle-Closure - diagnosis ; Gonioscopy ; Humans ; Intraocular Pressure ; Iris ; Medical diagnosis ; Optic nerve ; Optics ; Software ; Tomography ; Tomography, Optical Coherence</subject><ispartof>American journal of ophthalmology, 2022-01, Vol.233, p.68-77</ispartof><rights>2021</rights><rights>Published by Elsevier Inc.</rights><rights>Copyright Elsevier Limited Jan 2022</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c381t-5a11721baddc21c161164ef30ed5793ffdae54f82f8f2b35c283b5d71e1b1773</citedby><cites>FETCH-LOGICAL-c381t-5a11721baddc21c161164ef30ed5793ffdae54f82f8f2b35c283b5d71e1b1773</cites><orcidid>0000-0003-0431-531X ; 0000-0003-3820-1257 ; 0000-0001-7649-6952 ; 0000-0002-2772-3677</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/34283974$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ma, Ping</creatorcontrib><creatorcontrib>Wu, Yanyan</creatorcontrib><creatorcontrib>Oatts, Julius</creatorcontrib><creatorcontrib>Patlidanon, Jutima</creatorcontrib><creatorcontrib>Yu, Yinxi</creatorcontrib><creatorcontrib>Ying, Gui-Shuang</creatorcontrib><creatorcontrib>Kline, Brad</creatorcontrib><creatorcontrib>Tun, Tin A.</creatorcontrib><creatorcontrib>He, Mingguang</creatorcontrib><creatorcontrib>Aung, Tin</creatorcontrib><creatorcontrib>Li, Shuning</creatorcontrib><creatorcontrib>Yang, Yangfan</creatorcontrib><creatorcontrib>Han, Ying</creatorcontrib><title>Evaluation of the Diagnostic Performance of Swept-Source Anterior Segment Optical Coherence Tomography in Primary Angle Closure Disease</title><title>American journal of ophthalmology</title><addtitle>Am J Ophthalmol</addtitle><description>To evaluate the diagnostic performance of swept-source anterior segment optical coherence tomography (SS-OCT) in differentiating eyes with primary angle closure disease (PACD) from eyes of control subjects, as well as eyes with PAC and PAC glaucoma (PACG) from eyes with PAC suspect (PACS) disease.
Multicenter cross-sectional study.
Chinese patients were classified into control, PACS, and PAC/PACG groups. The area under the receiving operating characteristic curve (AUC) from logistic regression models was used to evaluate discriminating ability. Sensitivity and specificity were calculated, and performance of the models was validated using an independent dataset.
A total of 2928 SS-OCT images from 366 eyes of 260 patients were recruited to develop diagnostic models. The validation dataset included 1176 SS-OCT images from 147 eyes of 143 patients. For distinguishing PACD from control eyes, average anterior chamber depth had the highest AUC (0.94). With a cutoff of 2.2 mm for average anterior chamber depth, the sensitivity and specificity were 90.2% and 85.2% in the training set. For distinguishing PAC/PACG from PACS, a multivariate model had an AUC of 0.83, with sensitivity and specificity of 82.0% and 62.8% in the training set. The validation set confirmed the findings.
SS-OCT of the anterior segment showed excellent diagnostic performance distinguishing PACD from normal eyes and moderate diagnostic ability distinguishing eyes with PAC/PACG from eyes with PACS. ACD alone may provide a simple and effective way to diagnose PACD from control subjects. As ACD can be obtained using other more available modalities, this has implications for the early diagnosis of PACD.</description><subject>Anterior Eye Segment - diagnostic imaging</subject><subject>Cataracts</subject><subject>Cross-Sectional Studies</subject><subject>Datasets</subject><subject>Disease</subject><subject>Generalized linear models</subject><subject>Glaucoma</subject><subject>Glaucoma, Angle-Closure - diagnosis</subject><subject>Gonioscopy</subject><subject>Humans</subject><subject>Intraocular Pressure</subject><subject>Iris</subject><subject>Medical diagnosis</subject><subject>Optic nerve</subject><subject>Optics</subject><subject>Software</subject><subject>Tomography</subject><subject>Tomography, Optical Coherence</subject><issn>0002-9394</issn><issn>1879-1891</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNp9kc1u1DAUhS1ERYe2D8AGWWLDJqmvnV-xqoYWkCq10szecpzrGUdJHOykqE_Aa9fRFBYsWFlX_s6xzz2EfACWAoPiuktV51LOOKSsSJkQb8gGqrJOoKrhLdkwxnhSizo7J-9D6OJYlFn5jpyLjFeiLrMN-X37pPpFzdaN1Bk6H5F-teowujBbTR_RG-cHNWpcb3e_cJqTnVt8nG_GGb11nu7wMOA404cpSlRPt-6IHlfJ3g3u4NV0fKZ2pI_eDso_R-GhR7rtXVj8-lpAFfCSnBnVB7x6PS_I_u52v_2e3D98-7G9uU-0qGBOcgVQcmhU22oOGgqAIkMjGLZ5WQtjWoV5ZipuKsMbkeuYs8nbEhAaKEtxQT6fbCfvfi4YZjnYoLHv1YhuCZLnuag48LyO6Kd_0C4GH-PnJC9YzaosF6shnCjtXQgejZxOMSUwuZYkOxlLkmtJkhUylhQ1H1-dl2bA9q_iTysR-HICMG7iyaKXQdt1o631qGfZOvsf-xe1NKNI</recordid><startdate>202201</startdate><enddate>202201</enddate><creator>Ma, Ping</creator><creator>Wu, Yanyan</creator><creator>Oatts, Julius</creator><creator>Patlidanon, Jutima</creator><creator>Yu, Yinxi</creator><creator>Ying, Gui-Shuang</creator><creator>Kline, Brad</creator><creator>Tun, Tin A.</creator><creator>He, Mingguang</creator><creator>Aung, Tin</creator><creator>Li, Shuning</creator><creator>Yang, Yangfan</creator><creator>Han, Ying</creator><general>Elsevier Inc</general><general>Elsevier Limited</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>K9.</scope><scope>NAPCQ</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-0431-531X</orcidid><orcidid>https://orcid.org/0000-0003-3820-1257</orcidid><orcidid>https://orcid.org/0000-0001-7649-6952</orcidid><orcidid>https://orcid.org/0000-0002-2772-3677</orcidid></search><sort><creationdate>202201</creationdate><title>Evaluation of the Diagnostic Performance of Swept-Source Anterior Segment Optical Coherence Tomography in Primary Angle Closure Disease</title><author>Ma, Ping ; Wu, Yanyan ; Oatts, Julius ; Patlidanon, Jutima ; Yu, Yinxi ; Ying, Gui-Shuang ; Kline, Brad ; Tun, Tin A. ; He, Mingguang ; Aung, Tin ; Li, Shuning ; Yang, Yangfan ; Han, Ying</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c381t-5a11721baddc21c161164ef30ed5793ffdae54f82f8f2b35c283b5d71e1b1773</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Anterior Eye Segment - diagnostic imaging</topic><topic>Cataracts</topic><topic>Cross-Sectional Studies</topic><topic>Datasets</topic><topic>Disease</topic><topic>Generalized linear models</topic><topic>Glaucoma</topic><topic>Glaucoma, Angle-Closure - diagnosis</topic><topic>Gonioscopy</topic><topic>Humans</topic><topic>Intraocular Pressure</topic><topic>Iris</topic><topic>Medical diagnosis</topic><topic>Optic nerve</topic><topic>Optics</topic><topic>Software</topic><topic>Tomography</topic><topic>Tomography, Optical Coherence</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ma, Ping</creatorcontrib><creatorcontrib>Wu, Yanyan</creatorcontrib><creatorcontrib>Oatts, Julius</creatorcontrib><creatorcontrib>Patlidanon, Jutima</creatorcontrib><creatorcontrib>Yu, Yinxi</creatorcontrib><creatorcontrib>Ying, Gui-Shuang</creatorcontrib><creatorcontrib>Kline, Brad</creatorcontrib><creatorcontrib>Tun, Tin A.</creatorcontrib><creatorcontrib>He, Mingguang</creatorcontrib><creatorcontrib>Aung, Tin</creatorcontrib><creatorcontrib>Li, Shuning</creatorcontrib><creatorcontrib>Yang, Yangfan</creatorcontrib><creatorcontrib>Han, Ying</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Nursing & Allied Health Premium</collection><collection>MEDLINE - Academic</collection><jtitle>American journal of ophthalmology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ma, Ping</au><au>Wu, Yanyan</au><au>Oatts, Julius</au><au>Patlidanon, Jutima</au><au>Yu, Yinxi</au><au>Ying, Gui-Shuang</au><au>Kline, Brad</au><au>Tun, Tin A.</au><au>He, Mingguang</au><au>Aung, Tin</au><au>Li, Shuning</au><au>Yang, Yangfan</au><au>Han, Ying</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of the Diagnostic Performance of Swept-Source Anterior Segment Optical Coherence Tomography in Primary Angle Closure Disease</atitle><jtitle>American journal of ophthalmology</jtitle><addtitle>Am J Ophthalmol</addtitle><date>2022-01</date><risdate>2022</risdate><volume>233</volume><spage>68</spage><epage>77</epage><pages>68-77</pages><issn>0002-9394</issn><eissn>1879-1891</eissn><abstract>To evaluate the diagnostic performance of swept-source anterior segment optical coherence tomography (SS-OCT) in differentiating eyes with primary angle closure disease (PACD) from eyes of control subjects, as well as eyes with PAC and PAC glaucoma (PACG) from eyes with PAC suspect (PACS) disease.
Multicenter cross-sectional study.
Chinese patients were classified into control, PACS, and PAC/PACG groups. The area under the receiving operating characteristic curve (AUC) from logistic regression models was used to evaluate discriminating ability. Sensitivity and specificity were calculated, and performance of the models was validated using an independent dataset.
A total of 2928 SS-OCT images from 366 eyes of 260 patients were recruited to develop diagnostic models. The validation dataset included 1176 SS-OCT images from 147 eyes of 143 patients. For distinguishing PACD from control eyes, average anterior chamber depth had the highest AUC (0.94). With a cutoff of 2.2 mm for average anterior chamber depth, the sensitivity and specificity were 90.2% and 85.2% in the training set. For distinguishing PAC/PACG from PACS, a multivariate model had an AUC of 0.83, with sensitivity and specificity of 82.0% and 62.8% in the training set. The validation set confirmed the findings.
SS-OCT of the anterior segment showed excellent diagnostic performance distinguishing PACD from normal eyes and moderate diagnostic ability distinguishing eyes with PAC/PACG from eyes with PACS. ACD alone may provide a simple and effective way to diagnose PACD from control subjects. As ACD can be obtained using other more available modalities, this has implications for the early diagnosis of PACD.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>34283974</pmid><doi>10.1016/j.ajo.2021.06.033</doi><tpages>10</tpages><orcidid>https://orcid.org/0000-0003-0431-531X</orcidid><orcidid>https://orcid.org/0000-0003-3820-1257</orcidid><orcidid>https://orcid.org/0000-0001-7649-6952</orcidid><orcidid>https://orcid.org/0000-0002-2772-3677</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0002-9394 |
ispartof | American journal of ophthalmology, 2022-01, Vol.233, p.68-77 |
issn | 0002-9394 1879-1891 |
language | eng |
recordid | cdi_proquest_miscellaneous_2553821259 |
source | Elsevier |
subjects | Anterior Eye Segment - diagnostic imaging Cataracts Cross-Sectional Studies Datasets Disease Generalized linear models Glaucoma Glaucoma, Angle-Closure - diagnosis Gonioscopy Humans Intraocular Pressure Iris Medical diagnosis Optic nerve Optics Software Tomography Tomography, Optical Coherence |
title | Evaluation of the Diagnostic Performance of Swept-Source Anterior Segment Optical Coherence Tomography in Primary Angle Closure Disease |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T08%3A23%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20the%20Diagnostic%20Performance%20of%20Swept-Source%20Anterior%20Segment%20Optical%20Coherence%20Tomography%20in%20Primary%20Angle%20Closure%20Disease&rft.jtitle=American%20journal%20of%20ophthalmology&rft.au=Ma,%20Ping&rft.date=2022-01&rft.volume=233&rft.spage=68&rft.epage=77&rft.pages=68-77&rft.issn=0002-9394&rft.eissn=1879-1891&rft_id=info:doi/10.1016/j.ajo.2021.06.033&rft_dat=%3Cproquest_cross%3E2553821259%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c381t-5a11721baddc21c161164ef30ed5793ffdae54f82f8f2b35c283b5d71e1b1773%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2609084537&rft_id=info:pmid/34283974&rfr_iscdi=true |