Clinical performance of posterior monolithic zirconia implant-supported fixed dental prostheses with angulated screw channels: A 3-year prospective cohort study

The choice of retention type of an implant-supported fixed dental prosthesis (FDP) becomes critical when the dental implant is not placed in a prosthetically ideal location. In recent years, computer-aided design and computer-aided manufacturing (CAD-CAM) technology has enabled the correction of the...

Full description

Saved in:
Bibliographic Details
Published in:The Journal of prosthetic dentistry 2023-04, Vol.129 (4), p.566-572
Main Authors: Di Fiore, Adolfo, Granata, Stefano, Monaco, Carlo, Stellini, Edoardo, Yilmaz, Burak
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c368t-185f9196e6f5cf6b72374a6972b7a394d94de13c9469a59d1fada73c98ee82923
cites cdi_FETCH-LOGICAL-c368t-185f9196e6f5cf6b72374a6972b7a394d94de13c9469a59d1fada73c98ee82923
container_end_page 572
container_issue 4
container_start_page 566
container_title The Journal of prosthetic dentistry
container_volume 129
creator Di Fiore, Adolfo
Granata, Stefano
Monaco, Carlo
Stellini, Edoardo
Yilmaz, Burak
description The choice of retention type of an implant-supported fixed dental prosthesis (FDP) becomes critical when the dental implant is not placed in a prosthetically ideal location. In recent years, computer-aided design and computer-aided manufacturing (CAD-CAM) technology has enabled the correction of the location of screw access hole depending on the clinical needs of the patient. However, how FPDs with angulated screw channels (ASCs) perform clinically is unclear. The purpose of this prospective clinical study was to evaluate the mechanical complications and crestal bone loss (CBL) when posterior monolithic zirconia implant-supported FDPs with an ASC are used. Participants (N=37) with a missing single posterior tooth or multiple teeth, sufficient bone height, and an implant site without infection were included. Each participant received parallel-walled implants (Nobel Parallel CC) of 7-, 8.5-, or 10-mm length by using a 1-stage approach. After 4 months of healing, a conventional impression was made, and a digital workflow was followed. Monolithic zirconia restorations (Katana ML) were milled, stained, and mechanically attached to a titanium base (NobelProcera ASC abutment). CBL was measured from radiographs at 6, 12, 24, and 36 months after the placement of the prosthesis. Implant and prosthetic characteristics including implant diameter, implant length, screw channel angle (angle≤15 degrees versus angle>16 degrees), prosthetic type (single crown versus multiple-unit FDP), and antagonist dentition (natural versus prosthesis) were also recorded. A generalized linear mixed model with a log link was estimated to assess the independent predictors of CBL among the angles of ASC-retained definitive restorations and the clinically relevant variables (α=.05). Thirty-seven participants received 51 implants, and the median follow-up period was 30 months (interquartile range: 22-36). Two single-crown implants failed within the first 12 months of delivery. The implant and restoration survival rate was 96% at 36 months. Screw loosening was recorded in 2 study participants. After a follow-up of 36 months, the mean ±standard deviation CBL value was 0.15 ±0.14 mm with an increase over time (P.05). CBL was not associated with the angle of ASC, implant diameter, implant length, prosthetic type, or antagonist when posterior mon
doi_str_mv 10.1016/j.prosdent.2021.06.043
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2558091297</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0022391321003619</els_id><sourcerecordid>2558091297</sourcerecordid><originalsourceid>FETCH-LOGICAL-c368t-185f9196e6f5cf6b72374a6972b7a394d94de13c9469a59d1fada73c98ee82923</originalsourceid><addsrcrecordid>eNqFkc1u1DAUhS1ERYe2r1B5ySapfxInZkU1AopUiU1ZWx77mvEoiYPttAxPw6PiMC1bJMvWlc659_h-CF1TUlNCxc2hnmNIFqZcM8JoTURNGv4KbSiRXSX6hr5GG0IYq7ik_By9TelACOnbjr5B57zhTdMyuUG_t4OfvNEDniG6EEc9GcDB4TmkDNGHiMcwhcHnvTf4l48mTF5jP86DnnKVlnkOMYPFzv8s9xpo7VWy5T0kSPipOLGevi-DXmXJRHjCZq-nCYb0Ht9iXh1Bx7-WGUz2j4BN2JemOOXFHi_RmdNDgqvn9wJ9-_TxYXtX3X_9_GV7e18ZLvpc0b51kkoBwrXGiV3HeNdoITu26zSXjS0HKDeyEVK30lKnre5K3QP0TDJ-gd6d-pYgPxZIWY0-GRjKNyEsSbG27YmkTHZFKk5SUzKnCE7N0Y86HhUlaqWjDuqFjlrpKCJUoVOM188zlt0I9p_tBUcRfDgJym7g0UNUyXgoRKyPZTfKBv-_GX8AOWipPg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2558091297</pqid></control><display><type>article</type><title>Clinical performance of posterior monolithic zirconia implant-supported fixed dental prostheses with angulated screw channels: A 3-year prospective cohort study</title><source>ScienceDirect Freedom Collection</source><creator>Di Fiore, Adolfo ; Granata, Stefano ; Monaco, Carlo ; Stellini, Edoardo ; Yilmaz, Burak</creator><creatorcontrib>Di Fiore, Adolfo ; Granata, Stefano ; Monaco, Carlo ; Stellini, Edoardo ; Yilmaz, Burak</creatorcontrib><description>The choice of retention type of an implant-supported fixed dental prosthesis (FDP) becomes critical when the dental implant is not placed in a prosthetically ideal location. In recent years, computer-aided design and computer-aided manufacturing (CAD-CAM) technology has enabled the correction of the location of screw access hole depending on the clinical needs of the patient. However, how FPDs with angulated screw channels (ASCs) perform clinically is unclear. The purpose of this prospective clinical study was to evaluate the mechanical complications and crestal bone loss (CBL) when posterior monolithic zirconia implant-supported FDPs with an ASC are used. Participants (N=37) with a missing single posterior tooth or multiple teeth, sufficient bone height, and an implant site without infection were included. Each participant received parallel-walled implants (Nobel Parallel CC) of 7-, 8.5-, or 10-mm length by using a 1-stage approach. After 4 months of healing, a conventional impression was made, and a digital workflow was followed. Monolithic zirconia restorations (Katana ML) were milled, stained, and mechanically attached to a titanium base (NobelProcera ASC abutment). CBL was measured from radiographs at 6, 12, 24, and 36 months after the placement of the prosthesis. Implant and prosthetic characteristics including implant diameter, implant length, screw channel angle (angle≤15 degrees versus angle&gt;16 degrees), prosthetic type (single crown versus multiple-unit FDP), and antagonist dentition (natural versus prosthesis) were also recorded. A generalized linear mixed model with a log link was estimated to assess the independent predictors of CBL among the angles of ASC-retained definitive restorations and the clinically relevant variables (α=.05). Thirty-seven participants received 51 implants, and the median follow-up period was 30 months (interquartile range: 22-36). Two single-crown implants failed within the first 12 months of delivery. The implant and restoration survival rate was 96% at 36 months. Screw loosening was recorded in 2 study participants. After a follow-up of 36 months, the mean ±standard deviation CBL value was 0.15 ±0.14 mm with an increase over time (P&lt;.001). The effect of the angle of ASC, implant diameter, implant length, prosthetic type, and antagonist on the CBL was not statistically significant (P&gt;.05). CBL was not associated with the angle of ASC, implant diameter, implant length, prosthetic type, or antagonist when posterior monolithic zirconia implant-supported FDPs with ASCs were used. Screw loosening in 2 situations was the only mechanical complication during the first 3 years of service.</description><identifier>ISSN: 0022-3913</identifier><identifier>EISSN: 1097-6841</identifier><identifier>DOI: 10.1016/j.prosdent.2021.06.043</identifier><identifier>PMID: 34344529</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Bone Screws ; Dental Prosthesis, Implant-Supported ; Humans ; Prospective Studies ; Zirconium</subject><ispartof>The Journal of prosthetic dentistry, 2023-04, Vol.129 (4), p.566-572</ispartof><rights>2021 Editorial Council for the Journal of Prosthetic Dentistry</rights><rights>Copyright © 2021 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c368t-185f9196e6f5cf6b72374a6972b7a394d94de13c9469a59d1fada73c98ee82923</citedby><cites>FETCH-LOGICAL-c368t-185f9196e6f5cf6b72374a6972b7a394d94de13c9469a59d1fada73c98ee82923</cites><orcidid>0000-0002-1766-2567</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/34344529$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Di Fiore, Adolfo</creatorcontrib><creatorcontrib>Granata, Stefano</creatorcontrib><creatorcontrib>Monaco, Carlo</creatorcontrib><creatorcontrib>Stellini, Edoardo</creatorcontrib><creatorcontrib>Yilmaz, Burak</creatorcontrib><title>Clinical performance of posterior monolithic zirconia implant-supported fixed dental prostheses with angulated screw channels: A 3-year prospective cohort study</title><title>The Journal of prosthetic dentistry</title><addtitle>J Prosthet Dent</addtitle><description>The choice of retention type of an implant-supported fixed dental prosthesis (FDP) becomes critical when the dental implant is not placed in a prosthetically ideal location. In recent years, computer-aided design and computer-aided manufacturing (CAD-CAM) technology has enabled the correction of the location of screw access hole depending on the clinical needs of the patient. However, how FPDs with angulated screw channels (ASCs) perform clinically is unclear. The purpose of this prospective clinical study was to evaluate the mechanical complications and crestal bone loss (CBL) when posterior monolithic zirconia implant-supported FDPs with an ASC are used. Participants (N=37) with a missing single posterior tooth or multiple teeth, sufficient bone height, and an implant site without infection were included. Each participant received parallel-walled implants (Nobel Parallel CC) of 7-, 8.5-, or 10-mm length by using a 1-stage approach. After 4 months of healing, a conventional impression was made, and a digital workflow was followed. Monolithic zirconia restorations (Katana ML) were milled, stained, and mechanically attached to a titanium base (NobelProcera ASC abutment). CBL was measured from radiographs at 6, 12, 24, and 36 months after the placement of the prosthesis. Implant and prosthetic characteristics including implant diameter, implant length, screw channel angle (angle≤15 degrees versus angle&gt;16 degrees), prosthetic type (single crown versus multiple-unit FDP), and antagonist dentition (natural versus prosthesis) were also recorded. A generalized linear mixed model with a log link was estimated to assess the independent predictors of CBL among the angles of ASC-retained definitive restorations and the clinically relevant variables (α=.05). Thirty-seven participants received 51 implants, and the median follow-up period was 30 months (interquartile range: 22-36). Two single-crown implants failed within the first 12 months of delivery. The implant and restoration survival rate was 96% at 36 months. Screw loosening was recorded in 2 study participants. After a follow-up of 36 months, the mean ±standard deviation CBL value was 0.15 ±0.14 mm with an increase over time (P&lt;.001). The effect of the angle of ASC, implant diameter, implant length, prosthetic type, and antagonist on the CBL was not statistically significant (P&gt;.05). CBL was not associated with the angle of ASC, implant diameter, implant length, prosthetic type, or antagonist when posterior monolithic zirconia implant-supported FDPs with ASCs were used. Screw loosening in 2 situations was the only mechanical complication during the first 3 years of service.</description><subject>Bone Screws</subject><subject>Dental Prosthesis, Implant-Supported</subject><subject>Humans</subject><subject>Prospective Studies</subject><subject>Zirconium</subject><issn>0022-3913</issn><issn>1097-6841</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNqFkc1u1DAUhS1ERYe2r1B5ySapfxInZkU1AopUiU1ZWx77mvEoiYPttAxPw6PiMC1bJMvWlc659_h-CF1TUlNCxc2hnmNIFqZcM8JoTURNGv4KbSiRXSX6hr5GG0IYq7ik_By9TelACOnbjr5B57zhTdMyuUG_t4OfvNEDniG6EEc9GcDB4TmkDNGHiMcwhcHnvTf4l48mTF5jP86DnnKVlnkOMYPFzv8s9xpo7VWy5T0kSPipOLGevi-DXmXJRHjCZq-nCYb0Ht9iXh1Bx7-WGUz2j4BN2JemOOXFHi_RmdNDgqvn9wJ9-_TxYXtX3X_9_GV7e18ZLvpc0b51kkoBwrXGiV3HeNdoITu26zSXjS0HKDeyEVK30lKnre5K3QP0TDJ-gd6d-pYgPxZIWY0-GRjKNyEsSbG27YmkTHZFKk5SUzKnCE7N0Y86HhUlaqWjDuqFjlrpKCJUoVOM188zlt0I9p_tBUcRfDgJym7g0UNUyXgoRKyPZTfKBv-_GX8AOWipPg</recordid><startdate>202304</startdate><enddate>202304</enddate><creator>Di Fiore, Adolfo</creator><creator>Granata, Stefano</creator><creator>Monaco, Carlo</creator><creator>Stellini, Edoardo</creator><creator>Yilmaz, Burak</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-1766-2567</orcidid></search><sort><creationdate>202304</creationdate><title>Clinical performance of posterior monolithic zirconia implant-supported fixed dental prostheses with angulated screw channels: A 3-year prospective cohort study</title><author>Di Fiore, Adolfo ; Granata, Stefano ; Monaco, Carlo ; Stellini, Edoardo ; Yilmaz, Burak</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c368t-185f9196e6f5cf6b72374a6972b7a394d94de13c9469a59d1fada73c98ee82923</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Bone Screws</topic><topic>Dental Prosthesis, Implant-Supported</topic><topic>Humans</topic><topic>Prospective Studies</topic><topic>Zirconium</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Di Fiore, Adolfo</creatorcontrib><creatorcontrib>Granata, Stefano</creatorcontrib><creatorcontrib>Monaco, Carlo</creatorcontrib><creatorcontrib>Stellini, Edoardo</creatorcontrib><creatorcontrib>Yilmaz, Burak</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of prosthetic dentistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Di Fiore, Adolfo</au><au>Granata, Stefano</au><au>Monaco, Carlo</au><au>Stellini, Edoardo</au><au>Yilmaz, Burak</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Clinical performance of posterior monolithic zirconia implant-supported fixed dental prostheses with angulated screw channels: A 3-year prospective cohort study</atitle><jtitle>The Journal of prosthetic dentistry</jtitle><addtitle>J Prosthet Dent</addtitle><date>2023-04</date><risdate>2023</risdate><volume>129</volume><issue>4</issue><spage>566</spage><epage>572</epage><pages>566-572</pages><issn>0022-3913</issn><eissn>1097-6841</eissn><abstract>The choice of retention type of an implant-supported fixed dental prosthesis (FDP) becomes critical when the dental implant is not placed in a prosthetically ideal location. In recent years, computer-aided design and computer-aided manufacturing (CAD-CAM) technology has enabled the correction of the location of screw access hole depending on the clinical needs of the patient. However, how FPDs with angulated screw channels (ASCs) perform clinically is unclear. The purpose of this prospective clinical study was to evaluate the mechanical complications and crestal bone loss (CBL) when posterior monolithic zirconia implant-supported FDPs with an ASC are used. Participants (N=37) with a missing single posterior tooth or multiple teeth, sufficient bone height, and an implant site without infection were included. Each participant received parallel-walled implants (Nobel Parallel CC) of 7-, 8.5-, or 10-mm length by using a 1-stage approach. After 4 months of healing, a conventional impression was made, and a digital workflow was followed. Monolithic zirconia restorations (Katana ML) were milled, stained, and mechanically attached to a titanium base (NobelProcera ASC abutment). CBL was measured from radiographs at 6, 12, 24, and 36 months after the placement of the prosthesis. Implant and prosthetic characteristics including implant diameter, implant length, screw channel angle (angle≤15 degrees versus angle&gt;16 degrees), prosthetic type (single crown versus multiple-unit FDP), and antagonist dentition (natural versus prosthesis) were also recorded. A generalized linear mixed model with a log link was estimated to assess the independent predictors of CBL among the angles of ASC-retained definitive restorations and the clinically relevant variables (α=.05). Thirty-seven participants received 51 implants, and the median follow-up period was 30 months (interquartile range: 22-36). Two single-crown implants failed within the first 12 months of delivery. The implant and restoration survival rate was 96% at 36 months. Screw loosening was recorded in 2 study participants. After a follow-up of 36 months, the mean ±standard deviation CBL value was 0.15 ±0.14 mm with an increase over time (P&lt;.001). The effect of the angle of ASC, implant diameter, implant length, prosthetic type, and antagonist on the CBL was not statistically significant (P&gt;.05). CBL was not associated with the angle of ASC, implant diameter, implant length, prosthetic type, or antagonist when posterior monolithic zirconia implant-supported FDPs with ASCs were used. Screw loosening in 2 situations was the only mechanical complication during the first 3 years of service.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>34344529</pmid><doi>10.1016/j.prosdent.2021.06.043</doi><tpages>7</tpages><orcidid>https://orcid.org/0000-0002-1766-2567</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0022-3913
ispartof The Journal of prosthetic dentistry, 2023-04, Vol.129 (4), p.566-572
issn 0022-3913
1097-6841
language eng
recordid cdi_proquest_miscellaneous_2558091297
source ScienceDirect Freedom Collection
subjects Bone Screws
Dental Prosthesis, Implant-Supported
Humans
Prospective Studies
Zirconium
title Clinical performance of posterior monolithic zirconia implant-supported fixed dental prostheses with angulated screw channels: A 3-year prospective cohort study
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T06%3A22%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Clinical%20performance%20of%20posterior%20monolithic%20zirconia%20implant-supported%20fixed%20dental%20prostheses%20with%20angulated%20screw%20channels:%20A%203-year%20prospective%20cohort%20study&rft.jtitle=The%20Journal%20of%20prosthetic%20dentistry&rft.au=Di%20Fiore,%20Adolfo&rft.date=2023-04&rft.volume=129&rft.issue=4&rft.spage=566&rft.epage=572&rft.pages=566-572&rft.issn=0022-3913&rft.eissn=1097-6841&rft_id=info:doi/10.1016/j.prosdent.2021.06.043&rft_dat=%3Cproquest_cross%3E2558091297%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c368t-185f9196e6f5cf6b72374a6972b7a394d94de13c9469a59d1fada73c98ee82923%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2558091297&rft_id=info:pmid/34344529&rfr_iscdi=true