Loading…
Nanoscale Nickel-Based Thin Films as Highly Conductive Electrodes for Dielectric Elastomer Applications with Extremely High Stretchability up to 200
This paper presents on electromechanical characterization of thin film nickel-based wrinkled electrodes for dielectric elastomer (DE) applications. The investigation of a sandwich composed of a very soft and flexible elastomer carrying an ultrathin metallic electrode, together with its prestretch-de...
Saved in:
Published in: | ACS applied materials & interfaces 2021-08, Vol.13 (33), p.39894-39904 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-a307t-7dcdedba22dd90e18771b92af35bab804a629b9fc6b13e0bb6291c05774460f73 |
---|---|
cites | cdi_FETCH-LOGICAL-a307t-7dcdedba22dd90e18771b92af35bab804a629b9fc6b13e0bb6291c05774460f73 |
container_end_page | 39904 |
container_issue | 33 |
container_start_page | 39894 |
container_title | ACS applied materials & interfaces |
container_volume | 13 |
creator | Hubertus, Jonas Neu, Julian Croce, Sipontina Rizzello, Gianluca Seelecke, Stefan Schultes, Günter |
description | This paper presents on electromechanical characterization of thin film nickel-based wrinkled electrodes for dielectric elastomer (DE) applications. The investigation of a sandwich composed of a very soft and flexible elastomer carrying an ultrathin metallic electrode, together with its prestretch-dependent wrinkled structure of the electrode, facilitates the understanding of some of its interesting properties. Compared to conventional screen-printed carbon black electrodes, nickel-based thin film electrodes offer an ohmic resistance that is about 2 orders of magnitude lower. This remarkable feature makes it an advantageous electrode material alternative for the development of energy-efficient and high-frequency DE applications. Ultrathin (10–20 nm) layers are sputter deposited as electrodes onto either biaxially or, under pure-shear conditions, uniaxially prestretched silicone membranes. After the sputtering process, the membranes are allowed to relax whereby wrinkled out-of-plane buckled surfaces are obtained. With an initial resistance smaller than 400 Ω/square and a strong adhesion to the silicone, some electrode configurations are able to withstand strains up to 200% while remaining electrically conductive. A linear dependence of the capacitance on strain is revealed, as well as a long-term stability over 10 million cycles of mechanical stretching. All investigated thin film configurations of nickel and nickel–carbon films are suitable as compliant electrodes for DE actuators, as demonstrated by measuring the force characteristics with and without a high voltage. An increased level of prestretch shifts the resistance threshold of the electrode layers to even higher strain levels. In general, the best performance is achieved with pure metallic electrodes deposited on biaxially prestretched silicone membranes. |
doi_str_mv | 10.1021/acsami.1c10686 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2560297143</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2560297143</sourcerecordid><originalsourceid>FETCH-LOGICAL-a307t-7dcdedba22dd90e18771b92af35bab804a629b9fc6b13e0bb6291c05774460f73</originalsourceid><addsrcrecordid>eNp1UMtOwzAQjBBIlMKVs48IKcV2Xs2xlJYiVeVAOUdrZ0NdnDjYDtD_4INJKeLGaXdmZ0baCYJLRkeMcnYD0kGtRkwymo7To2DA8jgOxzzhx397HJ8GZ85tKU0jTpNB8LWCxjgJGslKyVfU4S04LMl6oxoyV7p2BBxZqJeN3pGpacpOevWOZKZRemtKdKQyltwp_CGU7C_gvKnRkknbaiXBK9M48qH8hsw-vcUa-6h9InnqkZcbEEorvyNdS7whnNLz4KQC7fDidw6D5_lsPV2Ey8f7h-lkGUJEMx9mpSyxFMB5WeYU2TjLmMg5VFEiQIxpDCnPRV7JVLAIqRA9ZJImWRbHKa2yaBhcHXJba946dL6olZOoNTRoOlfwJKU8z1gc9dLRQSqtcc5iVbRW1WB3BaPFvv7iUH_xW39vuD4Yer7Yms42_Sf_ib8BU7OJzg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2560297143</pqid></control><display><type>article</type><title>Nanoscale Nickel-Based Thin Films as Highly Conductive Electrodes for Dielectric Elastomer Applications with Extremely High Stretchability up to 200</title><source>American Chemical Society:Jisc Collections:American Chemical Society Read & Publish Agreement 2022-2024 (Reading list)</source><creator>Hubertus, Jonas ; Neu, Julian ; Croce, Sipontina ; Rizzello, Gianluca ; Seelecke, Stefan ; Schultes, Günter</creator><creatorcontrib>Hubertus, Jonas ; Neu, Julian ; Croce, Sipontina ; Rizzello, Gianluca ; Seelecke, Stefan ; Schultes, Günter</creatorcontrib><description>This paper presents on electromechanical characterization of thin film nickel-based wrinkled electrodes for dielectric elastomer (DE) applications. The investigation of a sandwich composed of a very soft and flexible elastomer carrying an ultrathin metallic electrode, together with its prestretch-dependent wrinkled structure of the electrode, facilitates the understanding of some of its interesting properties. Compared to conventional screen-printed carbon black electrodes, nickel-based thin film electrodes offer an ohmic resistance that is about 2 orders of magnitude lower. This remarkable feature makes it an advantageous electrode material alternative for the development of energy-efficient and high-frequency DE applications. Ultrathin (10–20 nm) layers are sputter deposited as electrodes onto either biaxially or, under pure-shear conditions, uniaxially prestretched silicone membranes. After the sputtering process, the membranes are allowed to relax whereby wrinkled out-of-plane buckled surfaces are obtained. With an initial resistance smaller than 400 Ω/square and a strong adhesion to the silicone, some electrode configurations are able to withstand strains up to 200% while remaining electrically conductive. A linear dependence of the capacitance on strain is revealed, as well as a long-term stability over 10 million cycles of mechanical stretching. All investigated thin film configurations of nickel and nickel–carbon films are suitable as compliant electrodes for DE actuators, as demonstrated by measuring the force characteristics with and without a high voltage. An increased level of prestretch shifts the resistance threshold of the electrode layers to even higher strain levels. In general, the best performance is achieved with pure metallic electrodes deposited on biaxially prestretched silicone membranes.</description><identifier>ISSN: 1944-8244</identifier><identifier>EISSN: 1944-8252</identifier><identifier>DOI: 10.1021/acsami.1c10686</identifier><language>eng</language><publisher>American Chemical Society</publisher><subject>Applications of Polymer, Composite, and Coating Materials</subject><ispartof>ACS applied materials & interfaces, 2021-08, Vol.13 (33), p.39894-39904</ispartof><rights>2021 The Authors. Published by American Chemical Society</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a307t-7dcdedba22dd90e18771b92af35bab804a629b9fc6b13e0bb6291c05774460f73</citedby><cites>FETCH-LOGICAL-a307t-7dcdedba22dd90e18771b92af35bab804a629b9fc6b13e0bb6291c05774460f73</cites><orcidid>0000-0001-9388-0454</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Hubertus, Jonas</creatorcontrib><creatorcontrib>Neu, Julian</creatorcontrib><creatorcontrib>Croce, Sipontina</creatorcontrib><creatorcontrib>Rizzello, Gianluca</creatorcontrib><creatorcontrib>Seelecke, Stefan</creatorcontrib><creatorcontrib>Schultes, Günter</creatorcontrib><title>Nanoscale Nickel-Based Thin Films as Highly Conductive Electrodes for Dielectric Elastomer Applications with Extremely High Stretchability up to 200</title><title>ACS applied materials & interfaces</title><addtitle>ACS Appl. Mater. Interfaces</addtitle><description>This paper presents on electromechanical characterization of thin film nickel-based wrinkled electrodes for dielectric elastomer (DE) applications. The investigation of a sandwich composed of a very soft and flexible elastomer carrying an ultrathin metallic electrode, together with its prestretch-dependent wrinkled structure of the electrode, facilitates the understanding of some of its interesting properties. Compared to conventional screen-printed carbon black electrodes, nickel-based thin film electrodes offer an ohmic resistance that is about 2 orders of magnitude lower. This remarkable feature makes it an advantageous electrode material alternative for the development of energy-efficient and high-frequency DE applications. Ultrathin (10–20 nm) layers are sputter deposited as electrodes onto either biaxially or, under pure-shear conditions, uniaxially prestretched silicone membranes. After the sputtering process, the membranes are allowed to relax whereby wrinkled out-of-plane buckled surfaces are obtained. With an initial resistance smaller than 400 Ω/square and a strong adhesion to the silicone, some electrode configurations are able to withstand strains up to 200% while remaining electrically conductive. A linear dependence of the capacitance on strain is revealed, as well as a long-term stability over 10 million cycles of mechanical stretching. All investigated thin film configurations of nickel and nickel–carbon films are suitable as compliant electrodes for DE actuators, as demonstrated by measuring the force characteristics with and without a high voltage. An increased level of prestretch shifts the resistance threshold of the electrode layers to even higher strain levels. In general, the best performance is achieved with pure metallic electrodes deposited on biaxially prestretched silicone membranes.</description><subject>Applications of Polymer, Composite, and Coating Materials</subject><issn>1944-8244</issn><issn>1944-8252</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNp1UMtOwzAQjBBIlMKVs48IKcV2Xs2xlJYiVeVAOUdrZ0NdnDjYDtD_4INJKeLGaXdmZ0baCYJLRkeMcnYD0kGtRkwymo7To2DA8jgOxzzhx397HJ8GZ85tKU0jTpNB8LWCxjgJGslKyVfU4S04LMl6oxoyV7p2BBxZqJeN3pGpacpOevWOZKZRemtKdKQyltwp_CGU7C_gvKnRkknbaiXBK9M48qH8hsw-vcUa-6h9InnqkZcbEEorvyNdS7whnNLz4KQC7fDidw6D5_lsPV2Ey8f7h-lkGUJEMx9mpSyxFMB5WeYU2TjLmMg5VFEiQIxpDCnPRV7JVLAIqRA9ZJImWRbHKa2yaBhcHXJba946dL6olZOoNTRoOlfwJKU8z1gc9dLRQSqtcc5iVbRW1WB3BaPFvv7iUH_xW39vuD4Yer7Yms42_Sf_ib8BU7OJzg</recordid><startdate>20210825</startdate><enddate>20210825</enddate><creator>Hubertus, Jonas</creator><creator>Neu, Julian</creator><creator>Croce, Sipontina</creator><creator>Rizzello, Gianluca</creator><creator>Seelecke, Stefan</creator><creator>Schultes, Günter</creator><general>American Chemical Society</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-9388-0454</orcidid></search><sort><creationdate>20210825</creationdate><title>Nanoscale Nickel-Based Thin Films as Highly Conductive Electrodes for Dielectric Elastomer Applications with Extremely High Stretchability up to 200</title><author>Hubertus, Jonas ; Neu, Julian ; Croce, Sipontina ; Rizzello, Gianluca ; Seelecke, Stefan ; Schultes, Günter</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a307t-7dcdedba22dd90e18771b92af35bab804a629b9fc6b13e0bb6291c05774460f73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Applications of Polymer, Composite, and Coating Materials</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hubertus, Jonas</creatorcontrib><creatorcontrib>Neu, Julian</creatorcontrib><creatorcontrib>Croce, Sipontina</creatorcontrib><creatorcontrib>Rizzello, Gianluca</creatorcontrib><creatorcontrib>Seelecke, Stefan</creatorcontrib><creatorcontrib>Schultes, Günter</creatorcontrib><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>ACS applied materials & interfaces</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hubertus, Jonas</au><au>Neu, Julian</au><au>Croce, Sipontina</au><au>Rizzello, Gianluca</au><au>Seelecke, Stefan</au><au>Schultes, Günter</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Nanoscale Nickel-Based Thin Films as Highly Conductive Electrodes for Dielectric Elastomer Applications with Extremely High Stretchability up to 200</atitle><jtitle>ACS applied materials & interfaces</jtitle><addtitle>ACS Appl. Mater. Interfaces</addtitle><date>2021-08-25</date><risdate>2021</risdate><volume>13</volume><issue>33</issue><spage>39894</spage><epage>39904</epage><pages>39894-39904</pages><issn>1944-8244</issn><eissn>1944-8252</eissn><abstract>This paper presents on electromechanical characterization of thin film nickel-based wrinkled electrodes for dielectric elastomer (DE) applications. The investigation of a sandwich composed of a very soft and flexible elastomer carrying an ultrathin metallic electrode, together with its prestretch-dependent wrinkled structure of the electrode, facilitates the understanding of some of its interesting properties. Compared to conventional screen-printed carbon black electrodes, nickel-based thin film electrodes offer an ohmic resistance that is about 2 orders of magnitude lower. This remarkable feature makes it an advantageous electrode material alternative for the development of energy-efficient and high-frequency DE applications. Ultrathin (10–20 nm) layers are sputter deposited as electrodes onto either biaxially or, under pure-shear conditions, uniaxially prestretched silicone membranes. After the sputtering process, the membranes are allowed to relax whereby wrinkled out-of-plane buckled surfaces are obtained. With an initial resistance smaller than 400 Ω/square and a strong adhesion to the silicone, some electrode configurations are able to withstand strains up to 200% while remaining electrically conductive. A linear dependence of the capacitance on strain is revealed, as well as a long-term stability over 10 million cycles of mechanical stretching. All investigated thin film configurations of nickel and nickel–carbon films are suitable as compliant electrodes for DE actuators, as demonstrated by measuring the force characteristics with and without a high voltage. An increased level of prestretch shifts the resistance threshold of the electrode layers to even higher strain levels. In general, the best performance is achieved with pure metallic electrodes deposited on biaxially prestretched silicone membranes.</abstract><pub>American Chemical Society</pub><doi>10.1021/acsami.1c10686</doi><tpages>11</tpages><orcidid>https://orcid.org/0000-0001-9388-0454</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1944-8244 |
ispartof | ACS applied materials & interfaces, 2021-08, Vol.13 (33), p.39894-39904 |
issn | 1944-8244 1944-8252 |
language | eng |
recordid | cdi_proquest_miscellaneous_2560297143 |
source | American Chemical Society:Jisc Collections:American Chemical Society Read & Publish Agreement 2022-2024 (Reading list) |
subjects | Applications of Polymer, Composite, and Coating Materials |
title | Nanoscale Nickel-Based Thin Films as Highly Conductive Electrodes for Dielectric Elastomer Applications with Extremely High Stretchability up to 200 |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T00%3A07%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Nanoscale%20Nickel-Based%20Thin%20Films%20as%20Highly%20Conductive%20Electrodes%20for%20Dielectric%20Elastomer%20Applications%20with%20Extremely%20High%20Stretchability%20up%20to%20200&rft.jtitle=ACS%20applied%20materials%20&%20interfaces&rft.au=Hubertus,%20Jonas&rft.date=2021-08-25&rft.volume=13&rft.issue=33&rft.spage=39894&rft.epage=39904&rft.pages=39894-39904&rft.issn=1944-8244&rft.eissn=1944-8252&rft_id=info:doi/10.1021/acsami.1c10686&rft_dat=%3Cproquest_cross%3E2560297143%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-a307t-7dcdedba22dd90e18771b92af35bab804a629b9fc6b13e0bb6291c05774460f73%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2560297143&rft_id=info:pmid/&rfr_iscdi=true |