Pedicled fibular transfer for biologic knee extensor tendon reinsertion following proximal tibial resection in pediatric osteosarcoma: Long‐term outcomes

Introduction Proximal tibial sarcoma resections result in a reconstructive challenge, necessitating joint and extensor mechanism reconstruction. The gait and functional outcomes for children reconstructed with a combination of megaprosthesis and pedicled fibular flap for extensor mechanism reconstru...

Full description

Saved in:
Bibliographic Details
Published in:Microsurgery 2021-11, Vol.41 (8), p.753-761
Main Authors: Alexander, Will, Overland, Joseph, Thomason, Pamela, O'Sullivan, Mark, Donnan, Leo, Coombs, Christopher
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Introduction Proximal tibial sarcoma resections result in a reconstructive challenge, necessitating joint and extensor mechanism reconstruction. The gait and functional outcomes for children reconstructed with a combination of megaprosthesis and pedicled fibular flap for extensor mechanism reconstruction, are presented. Methods Four patients, aged 11–18 years old, were available for comprehensive analysis. The proximal tibial osteosarcoma was resected, and the reconstructive technique involved a megaprosthesis for the knee joint, used in combination with a pedicled fibula flap as a biologic structure for reinsertion of the knee extensor mechanism. Outcomes were measured with three‐dimensional gait analysis and patient questionnaires. Results Minor postoperative wound issues occurred in some patients, requiring debridement with skin grafting. One patient fractured their transferred fibula, requiring fixation. The follow up period ranged from 1.7 to 24 years postoperatively. The longevity and quality of reconstructions were strong, measured by both objective and patient‐reported outcomes. All patients reported independent walking >500 m in the Functional Mobility Scale and rated their walking as a nine or 10 (out of 10) on the Functional Assessment Questionnaire. Knee society scoring revealed overall satisfaction rate of 75–80%. No patients required gait aids. The gait profile analysis revealed effective gait patterns, with patterns deviating 5.4–7° from “typical gait.” Deviations >6.5° are considered abnormal. Conclusion The long‐term results of combining a megaprosthesis with a pedicled fibula flap for extensor reinsertion, revealed a high level of independent function. The patients performed well, without the need for aids, and gait study evidence of minimal gait deviations.
ISSN:0738-1085
1098-2752
DOI:10.1002/micr.30802