Purpose: One major challenge facing simultaneous positron emission tomography (PET)/ magnetic resonance imaging (MRI) is PET attenuation correction (AC) measurement and evaluation of its accuracy. There is a crucial need for the evaluation of current and emergent PET AC methodologies in terms of abs...

Full description

Saved in:
Bibliographic Details
Published in:Journal of medical imaging (Bellingham, Wash.) Wash.), 2021-09, Vol.8 (5), p.056001-056001
Main Authors: Hamdi, Mahdjoub, Natsuaki, Yutaka, Wangerin, Kristen A, An, Hongyu, St. James, Sarah, Kinahan, Paul E, Sunderland, John J, Larson, Peder E. Z, Hope, Thomas A, Laforest, Richard
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c434t-5220b37118d3510f4cc1ed53b8481c07196349ffd43b5669bb0b6b435211cf653
cites
container_end_page 056001
container_issue 5
container_start_page 056001
container_title Journal of medical imaging (Bellingham, Wash.)
container_volume 8
creator Hamdi, Mahdjoub
Natsuaki, Yutaka
Wangerin, Kristen A
An, Hongyu
St. James, Sarah
Kinahan, Paul E
Sunderland, John J
Larson, Peder E. Z
Hope, Thomas A
Laforest, Richard
description Purpose: One major challenge facing simultaneous positron emission tomography (PET)/ magnetic resonance imaging (MRI) is PET attenuation correction (AC) measurement and evaluation of its accuracy. There is a crucial need for the evaluation of current and emergent PET AC methodologies in terms of absolute quantitative accuracy in the reconstructed PET images. Approach: To address this need, we developed and evaluated a lesion insertion tool for PET/MRI that will facilitate this evaluation process. This tool was developed for the Biograph mMR and evaluated using phantom and patient data. Contrast recovery coefficients (CRC) from the NEMA IEC phantom of synthesized lesions were compared to measurements. In addition, SUV biases of lesions inserted in human brain and pelvis images were assessed from PET images reconstructed with MRI-based AC (MRAC) and CT-based AC (CTAC). Results: For cross-comparison PET/MRI scanners AC evaluation, we demonstrated that the developed lesion insertion tool can be harmonized with the GE-SIGNA lesion insertion tool. About
doi_str_mv 10.1117/1.JMI.8.5.056001
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2576911920</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2576911920</sourcerecordid><originalsourceid>FETCH-LOGICAL-c434t-5220b37118d3510f4cc1ed53b8481c07196349ffd43b5669bb0b6b435211cf653</originalsourceid><addsrcrecordid>eNp1kU1PwkAQhjdGIwS5ezI9emnZ2Y_SXkwMQcVAMAbPm3bZypLSxd0thn9vsUj04GlmMs-8M5kXoWvAEQAMBxA9zyZREvEI8xhjOENdQkkaMgr4_JRj0kF959a4IQBzAuwSdSjjccIBumg-3mVlnXltqsAUQea9qo6lNNYq-Z3qKngZLwaz10nwqf0qcPvKr5TXMiiVawGn7AG9QhdFVjrVP8YeensYL0ZP4XT-OBndT0PJKPMhJwTndAiQLCkHXDApQS05zROWgMRDSGPK0qJYMprzOE7zHOdxzmhzP8gi5rSH7lrdbZ1v1FKqytusFFurN5ndC5Np8bdT6ZV4NzuRMA6Eskbg9ihgzUetnBcb7aQqy6xSpnaC8GGcAqQENyhuUWmNc1YVpzWAxcEKAaKxQiSCi9aKZuTm93mngZ_HN0DYAm6rlVib2lbNu_4X_ALvNJJ5</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2576911920</pqid></control><display><type>article</type><title>Evaluation of attenuation correction in PET/MRI with synthetic lesion insertion</title><source>PubMed Central</source><creator>Hamdi, Mahdjoub ; Natsuaki, Yutaka ; Wangerin, Kristen A ; An, Hongyu ; St. James, Sarah ; Kinahan, Paul E ; Sunderland, John J ; Larson, Peder E. Z ; Hope, Thomas A ; Laforest, Richard</creator><creatorcontrib>Hamdi, Mahdjoub ; Natsuaki, Yutaka ; Wangerin, Kristen A ; An, Hongyu ; St. James, Sarah ; Kinahan, Paul E ; Sunderland, John J ; Larson, Peder E. Z ; Hope, Thomas A ; Laforest, Richard</creatorcontrib><description>Purpose: One major challenge facing simultaneous positron emission tomography (PET)/ magnetic resonance imaging (MRI) is PET attenuation correction (AC) measurement and evaluation of its accuracy. There is a crucial need for the evaluation of current and emergent PET AC methodologies in terms of absolute quantitative accuracy in the reconstructed PET images. Approach: To address this need, we developed and evaluated a lesion insertion tool for PET/MRI that will facilitate this evaluation process. This tool was developed for the Biograph mMR and evaluated using phantom and patient data. Contrast recovery coefficients (CRC) from the NEMA IEC phantom of synthesized lesions were compared to measurements. In addition, SUV biases of lesions inserted in human brain and pelvis images were assessed from PET images reconstructed with MRI-based AC (MRAC) and CT-based AC (CTAC). Results: For cross-comparison PET/MRI scanners AC evaluation, we demonstrated that the developed lesion insertion tool can be harmonized with the GE-SIGNA lesion insertion tool. About &lt;3  %   CRC curves difference between simulation and measurement was achieved. An average of 1.6% between harmonized simulated CRC curves obtained with mMR and SIGNA lesion insertion tools was achieved. A range of −5  %   to 12% MRAC to CTAC SUV bias was respectively achieved in the vicinity and inside bone tissues in patient images in two anatomical regions, the brain, and pelvis. Conclusions: A lesion insertion tool was developed for the Biograph mMR PET/MRI scanner and harmonized with the SIGNA PET/MRI lesion insertion tool. These tools will allow for an accurate evaluation of different PET/MRI AC approaches and permit exploration of subtle attenuation correction differences across systems.</description><identifier>ISSN: 2329-4302</identifier><identifier>EISSN: 2329-4310</identifier><identifier>DOI: 10.1117/1.JMI.8.5.056001</identifier><identifier>PMID: 34568511</identifier><language>eng</language><publisher>United States: Society of Photo-Optical Instrumentation Engineers</publisher><subject>Biomedical Applications in Molecular, Structural, and Functional Imaging</subject><ispartof>Journal of medical imaging (Bellingham, Wash.), 2021-09, Vol.8 (5), p.056001-056001</ispartof><rights>2021 Society of Photo-Optical Instrumentation Engineers (SPIE)</rights><rights>2021 Society of Photo-Optical Instrumentation Engineers (SPIE).</rights><rights>2021 Society of Photo-Optical Instrumentation Engineers (SPIE) 2021 Society of Photo-Optical Instrumentation Engineers</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c434t-5220b37118d3510f4cc1ed53b8481c07196349ffd43b5669bb0b6b435211cf653</citedby><orcidid>0000-0002-7647-3483 ; 0000-0001-6461-3306 ; 0000-0002-8081-2433 ; 0000-0003-4183-3634 ; 0000-0001-6459-2269 ; 0000-0002-0238-1439 ; 0000-0002-2228-5823</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC8451234/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC8451234/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,314,727,780,784,885,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/34568511$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Hamdi, Mahdjoub</creatorcontrib><creatorcontrib>Natsuaki, Yutaka</creatorcontrib><creatorcontrib>Wangerin, Kristen A</creatorcontrib><creatorcontrib>An, Hongyu</creatorcontrib><creatorcontrib>St. James, Sarah</creatorcontrib><creatorcontrib>Kinahan, Paul E</creatorcontrib><creatorcontrib>Sunderland, John J</creatorcontrib><creatorcontrib>Larson, Peder E. Z</creatorcontrib><creatorcontrib>Hope, Thomas A</creatorcontrib><creatorcontrib>Laforest, Richard</creatorcontrib><title>Evaluation of attenuation correction in PET/MRI with synthetic lesion insertion</title><title>Journal of medical imaging (Bellingham, Wash.)</title><addtitle>J. Med. Imag</addtitle><description>Purpose: One major challenge facing simultaneous positron emission tomography (PET)/ magnetic resonance imaging (MRI) is PET attenuation correction (AC) measurement and evaluation of its accuracy. There is a crucial need for the evaluation of current and emergent PET AC methodologies in terms of absolute quantitative accuracy in the reconstructed PET images. Approach: To address this need, we developed and evaluated a lesion insertion tool for PET/MRI that will facilitate this evaluation process. This tool was developed for the Biograph mMR and evaluated using phantom and patient data. Contrast recovery coefficients (CRC) from the NEMA IEC phantom of synthesized lesions were compared to measurements. In addition, SUV biases of lesions inserted in human brain and pelvis images were assessed from PET images reconstructed with MRI-based AC (MRAC) and CT-based AC (CTAC). Results: For cross-comparison PET/MRI scanners AC evaluation, we demonstrated that the developed lesion insertion tool can be harmonized with the GE-SIGNA lesion insertion tool. About &lt;3  %   CRC curves difference between simulation and measurement was achieved. An average of 1.6% between harmonized simulated CRC curves obtained with mMR and SIGNA lesion insertion tools was achieved. A range of −5  %   to 12% MRAC to CTAC SUV bias was respectively achieved in the vicinity and inside bone tissues in patient images in two anatomical regions, the brain, and pelvis. Conclusions: A lesion insertion tool was developed for the Biograph mMR PET/MRI scanner and harmonized with the SIGNA PET/MRI lesion insertion tool. These tools will allow for an accurate evaluation of different PET/MRI AC approaches and permit exploration of subtle attenuation correction differences across systems.</description><subject>Biomedical Applications in Molecular, Structural, and Functional Imaging</subject><issn>2329-4302</issn><issn>2329-4310</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNp1kU1PwkAQhjdGIwS5ezI9emnZ2Y_SXkwMQcVAMAbPm3bZypLSxd0thn9vsUj04GlmMs-8M5kXoWvAEQAMBxA9zyZREvEI8xhjOENdQkkaMgr4_JRj0kF959a4IQBzAuwSdSjjccIBumg-3mVlnXltqsAUQea9qo6lNNYq-Z3qKngZLwaz10nwqf0qcPvKr5TXMiiVawGn7AG9QhdFVjrVP8YeensYL0ZP4XT-OBndT0PJKPMhJwTndAiQLCkHXDApQS05zROWgMRDSGPK0qJYMprzOE7zHOdxzmhzP8gi5rSH7lrdbZ1v1FKqytusFFurN5ndC5Np8bdT6ZV4NzuRMA6Eskbg9ihgzUetnBcb7aQqy6xSpnaC8GGcAqQENyhuUWmNc1YVpzWAxcEKAaKxQiSCi9aKZuTm93mngZ_HN0DYAm6rlVib2lbNu_4X_ALvNJJ5</recordid><startdate>20210901</startdate><enddate>20210901</enddate><creator>Hamdi, Mahdjoub</creator><creator>Natsuaki, Yutaka</creator><creator>Wangerin, Kristen A</creator><creator>An, Hongyu</creator><creator>St. James, Sarah</creator><creator>Kinahan, Paul E</creator><creator>Sunderland, John J</creator><creator>Larson, Peder E. Z</creator><creator>Hope, Thomas A</creator><creator>Laforest, Richard</creator><general>Society of Photo-Optical Instrumentation Engineers</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0002-7647-3483</orcidid><orcidid>https://orcid.org/0000-0001-6461-3306</orcidid><orcidid>https://orcid.org/0000-0002-8081-2433</orcidid><orcidid>https://orcid.org/0000-0003-4183-3634</orcidid><orcidid>https://orcid.org/0000-0001-6459-2269</orcidid><orcidid>https://orcid.org/0000-0002-0238-1439</orcidid><orcidid>https://orcid.org/0000-0002-2228-5823</orcidid></search><sort><creationdate>20210901</creationdate><title>Evaluation of attenuation correction in PET/MRI with synthetic lesion insertion</title><author>Hamdi, Mahdjoub ; Natsuaki, Yutaka ; Wangerin, Kristen A ; An, Hongyu ; St. James, Sarah ; Kinahan, Paul E ; Sunderland, John J ; Larson, Peder E. Z ; Hope, Thomas A ; Laforest, Richard</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c434t-5220b37118d3510f4cc1ed53b8481c07196349ffd43b5669bb0b6b435211cf653</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Biomedical Applications in Molecular, Structural, and Functional Imaging</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hamdi, Mahdjoub</creatorcontrib><creatorcontrib>Natsuaki, Yutaka</creatorcontrib><creatorcontrib>Wangerin, Kristen A</creatorcontrib><creatorcontrib>An, Hongyu</creatorcontrib><creatorcontrib>St. James, Sarah</creatorcontrib><creatorcontrib>Kinahan, Paul E</creatorcontrib><creatorcontrib>Sunderland, John J</creatorcontrib><creatorcontrib>Larson, Peder E. Z</creatorcontrib><creatorcontrib>Hope, Thomas A</creatorcontrib><creatorcontrib>Laforest, Richard</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Journal of medical imaging (Bellingham, Wash.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hamdi, Mahdjoub</au><au>Natsuaki, Yutaka</au><au>Wangerin, Kristen A</au><au>An, Hongyu</au><au>St. James, Sarah</au><au>Kinahan, Paul E</au><au>Sunderland, John J</au><au>Larson, Peder E. Z</au><au>Hope, Thomas A</au><au>Laforest, Richard</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of attenuation correction in PET/MRI with synthetic lesion insertion</atitle><jtitle>Journal of medical imaging (Bellingham, Wash.)</jtitle><addtitle>J. Med. Imag</addtitle><date>2021-09-01</date><risdate>2021</risdate><volume>8</volume><issue>5</issue><spage>056001</spage><epage>056001</epage><pages>056001-056001</pages><issn>2329-4302</issn><eissn>2329-4310</eissn><abstract>Purpose: One major challenge facing simultaneous positron emission tomography (PET)/ magnetic resonance imaging (MRI) is PET attenuation correction (AC) measurement and evaluation of its accuracy. There is a crucial need for the evaluation of current and emergent PET AC methodologies in terms of absolute quantitative accuracy in the reconstructed PET images. Approach: To address this need, we developed and evaluated a lesion insertion tool for PET/MRI that will facilitate this evaluation process. This tool was developed for the Biograph mMR and evaluated using phantom and patient data. Contrast recovery coefficients (CRC) from the NEMA IEC phantom of synthesized lesions were compared to measurements. In addition, SUV biases of lesions inserted in human brain and pelvis images were assessed from PET images reconstructed with MRI-based AC (MRAC) and CT-based AC (CTAC). Results: For cross-comparison PET/MRI scanners AC evaluation, we demonstrated that the developed lesion insertion tool can be harmonized with the GE-SIGNA lesion insertion tool. About &lt;3  %   CRC curves difference between simulation and measurement was achieved. An average of 1.6% between harmonized simulated CRC curves obtained with mMR and SIGNA lesion insertion tools was achieved. A range of −5  %   to 12% MRAC to CTAC SUV bias was respectively achieved in the vicinity and inside bone tissues in patient images in two anatomical regions, the brain, and pelvis. Conclusions: A lesion insertion tool was developed for the Biograph mMR PET/MRI scanner and harmonized with the SIGNA PET/MRI lesion insertion tool. These tools will allow for an accurate evaluation of different PET/MRI AC approaches and permit exploration of subtle attenuation correction differences across systems.</abstract><cop>United States</cop><pub>Society of Photo-Optical Instrumentation Engineers</pub><pmid>34568511</pmid><doi>10.1117/1.JMI.8.5.056001</doi><tpages>1</tpages><orcidid>https://orcid.org/0000-0002-7647-3483</orcidid><orcidid>https://orcid.org/0000-0001-6461-3306</orcidid><orcidid>https://orcid.org/0000-0002-8081-2433</orcidid><orcidid>https://orcid.org/0000-0003-4183-3634</orcidid><orcidid>https://orcid.org/0000-0001-6459-2269</orcidid><orcidid>https://orcid.org/0000-0002-0238-1439</orcidid><orcidid>https://orcid.org/0000-0002-2228-5823</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2329-4302
ispartof Journal of medical imaging (Bellingham, Wash.), 2021-09, Vol.8 (5), p.056001-056001
issn 2329-4302
2329-4310
language eng
recordid cdi_proquest_miscellaneous_2576911920
source PubMed Central
subjects Biomedical Applications in Molecular, Structural, and Functional Imaging
title Evaluation of attenuation correction in PET/MRI with synthetic lesion insertion
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-30T12%3A49%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20attenuation%20correction%20in%20PET/MRI%20with%20synthetic%20lesion%20insertion&rft.jtitle=Journal%20of%20medical%20imaging%20(Bellingham,%20Wash.)&rft.au=Hamdi,%20Mahdjoub&rft.date=2021-09-01&rft.volume=8&rft.issue=5&rft.spage=056001&rft.epage=056001&rft.pages=056001-056001&rft.issn=2329-4302&rft.eissn=2329-4310&rft_id=info:doi/10.1117/1.JMI.8.5.056001&rft_dat=%3Cproquest_cross%3E2576911920%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c434t-5220b37118d3510f4cc1ed53b8481c07196349ffd43b5669bb0b6b435211cf653%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2576911920&rft_id=info:pmid/34568511&rfr_iscdi=true