Correlation between insertion torque and peri-implant bone strain during placement of orthodontic mini-implants: A finite element study
Insertion torque is the amount of torque exerted on the implant to tighten into the bone. We investigated whether insertion torque values could be correlated with the strain level in the peri-implant cortical bone resulting from mini-implant insertion. The insertion of a standard size mini-implant (...
Saved in:
Published in: | American journal of orthodontics and dentofacial orthopedics 2022-02, Vol.161 (2), p.248-254 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c359t-1ab3deb7b0ae91587c4f64947a18884072b83541ede442d2cb1a5141106c24e53 |
---|---|
cites | cdi_FETCH-LOGICAL-c359t-1ab3deb7b0ae91587c4f64947a18884072b83541ede442d2cb1a5141106c24e53 |
container_end_page | 254 |
container_issue | 2 |
container_start_page | 248 |
container_title | American journal of orthodontics and dentofacial orthopedics |
container_volume | 161 |
creator | Hung, Bui Quang Yu, Wonjae Park, Hyo-Sang Kyung, Hee-Moon Hong, Mihee |
description | Insertion torque is the amount of torque exerted on the implant to tighten into the bone. We investigated whether insertion torque values could be correlated with the strain level in the peri-implant cortical bone resulting from mini-implant insertion.
The insertion of a standard size mini-implant (φ 1.4 mm × 7 mm) into maxillary alveolar bone was simulated using the finite element method. A total of 3600 calculation steps were employed to numerically reproduce the mini-implant insertion process and analyze the insertion torque and strain distribution in bone. Special attention was given to the relationship between insertion torque values and strain level in the cortical bone at the final tightening. The strain level was quantified using the following 3 strain parameters: (1) average insertion strain, (2) peak insertion strain recorded near the mini-implant thread tips, and (3) the size of the damage zone in the cortical bone. Correlations between the insertion torque values and these 3 parameters were analyzed using linear regression.
Direct proportionality and strong correlation were found between the insertion torque values and each of the 3 strain parameters: average insertion strain (r2 = 0.91), peak insertion strain (r2 = 0.91), and the size of damage zone (r2 = 0.90) in the peri-implant cortical bone.
The results of this finite element method study demonstrated that insertion torque could serve as a reliable indicator of the strain level in the peri-implant cortical bone resulting from mini-implant insertion.
•Microimplant insertion strain was higher than the ultimate strength of bone.•The damage zone in cortical bone was approximately one-half of the microimplant diameter.•Correlations were found between insertion torque values and 3 strain parameters.•Parameters were average and peak insertion strain and size of the damage zone. |
doi_str_mv | 10.1016/j.ajodo.2020.07.042 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2580948214</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0889540621006016</els_id><sourcerecordid>2580948214</sourcerecordid><originalsourceid>FETCH-LOGICAL-c359t-1ab3deb7b0ae91587c4f64947a18884072b83541ede442d2cb1a5141106c24e53</originalsourceid><addsrcrecordid>eNp9kc9u1DAQxi1ERZfCEyAhH7kkjB0ndpA4VKsWkCpxgbPl2BPwKrEX2wH1CfrauN3SI6eRZn7f_PsIecOgZcCG94fWHKKLLQcOLcgWBH9GdgxG2Qyy58_JDpQam17AcE5e5nwAgFFweEHOOzHwkXdyR-72MSVcTPEx0AnLH8RAfciYHjIlpl8bUhMcPWLyjV-PiwmFTjEgzSUZH6jbkg8_aC1YXLEW40xjKj_rbqF4S1cfnoT5A72kc00UpLic8Fw2d_uKnM1myfj6MV6Q79dX3_afm5uvn77sL28a2_VjaZiZOoeTnMDgyHolrZgHMQppmFJKgOST6nrB0KEQ3HE7MdMzwRgMlgvsuwvy7tT3mGK9LBe9-mxxqcth3LLmvapPUpyJinYn1KaYc8JZH5NfTbrVDPS9A_qgHxzQ9w5okLo6UFVvHwds04ruSfPv5RX4eAKwnvnbY9LZegwWnU9oi3bR_3fAX0EsmsQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2580948214</pqid></control><display><type>article</type><title>Correlation between insertion torque and peri-implant bone strain during placement of orthodontic mini-implants: A finite element study</title><source>Elsevier</source><creator>Hung, Bui Quang ; Yu, Wonjae ; Park, Hyo-Sang ; Kyung, Hee-Moon ; Hong, Mihee</creator><creatorcontrib>Hung, Bui Quang ; Yu, Wonjae ; Park, Hyo-Sang ; Kyung, Hee-Moon ; Hong, Mihee</creatorcontrib><description>Insertion torque is the amount of torque exerted on the implant to tighten into the bone. We investigated whether insertion torque values could be correlated with the strain level in the peri-implant cortical bone resulting from mini-implant insertion.
The insertion of a standard size mini-implant (φ 1.4 mm × 7 mm) into maxillary alveolar bone was simulated using the finite element method. A total of 3600 calculation steps were employed to numerically reproduce the mini-implant insertion process and analyze the insertion torque and strain distribution in bone. Special attention was given to the relationship between insertion torque values and strain level in the cortical bone at the final tightening. The strain level was quantified using the following 3 strain parameters: (1) average insertion strain, (2) peak insertion strain recorded near the mini-implant thread tips, and (3) the size of the damage zone in the cortical bone. Correlations between the insertion torque values and these 3 parameters were analyzed using linear regression.
Direct proportionality and strong correlation were found between the insertion torque values and each of the 3 strain parameters: average insertion strain (r2 = 0.91), peak insertion strain (r2 = 0.91), and the size of damage zone (r2 = 0.90) in the peri-implant cortical bone.
The results of this finite element method study demonstrated that insertion torque could serve as a reliable indicator of the strain level in the peri-implant cortical bone resulting from mini-implant insertion.
•Microimplant insertion strain was higher than the ultimate strength of bone.•The damage zone in cortical bone was approximately one-half of the microimplant diameter.•Correlations were found between insertion torque values and 3 strain parameters.•Parameters were average and peak insertion strain and size of the damage zone.</description><identifier>ISSN: 0889-5406</identifier><identifier>EISSN: 1097-6752</identifier><identifier>DOI: 10.1016/j.ajodo.2020.07.042</identifier><identifier>PMID: 34629237</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Dental Implantation, Endosseous - adverse effects ; Dental Implants ; Finite Element Analysis ; Humans ; Maxilla ; Orthodontic Anchorage Procedures ; Torque</subject><ispartof>American journal of orthodontics and dentofacial orthopedics, 2022-02, Vol.161 (2), p.248-254</ispartof><rights>2021 American Association of Orthodontists</rights><rights>Copyright © 2021 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c359t-1ab3deb7b0ae91587c4f64947a18884072b83541ede442d2cb1a5141106c24e53</citedby><cites>FETCH-LOGICAL-c359t-1ab3deb7b0ae91587c4f64947a18884072b83541ede442d2cb1a5141106c24e53</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/34629237$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Hung, Bui Quang</creatorcontrib><creatorcontrib>Yu, Wonjae</creatorcontrib><creatorcontrib>Park, Hyo-Sang</creatorcontrib><creatorcontrib>Kyung, Hee-Moon</creatorcontrib><creatorcontrib>Hong, Mihee</creatorcontrib><title>Correlation between insertion torque and peri-implant bone strain during placement of orthodontic mini-implants: A finite element study</title><title>American journal of orthodontics and dentofacial orthopedics</title><addtitle>Am J Orthod Dentofacial Orthop</addtitle><description>Insertion torque is the amount of torque exerted on the implant to tighten into the bone. We investigated whether insertion torque values could be correlated with the strain level in the peri-implant cortical bone resulting from mini-implant insertion.
The insertion of a standard size mini-implant (φ 1.4 mm × 7 mm) into maxillary alveolar bone was simulated using the finite element method. A total of 3600 calculation steps were employed to numerically reproduce the mini-implant insertion process and analyze the insertion torque and strain distribution in bone. Special attention was given to the relationship between insertion torque values and strain level in the cortical bone at the final tightening. The strain level was quantified using the following 3 strain parameters: (1) average insertion strain, (2) peak insertion strain recorded near the mini-implant thread tips, and (3) the size of the damage zone in the cortical bone. Correlations between the insertion torque values and these 3 parameters were analyzed using linear regression.
Direct proportionality and strong correlation were found between the insertion torque values and each of the 3 strain parameters: average insertion strain (r2 = 0.91), peak insertion strain (r2 = 0.91), and the size of damage zone (r2 = 0.90) in the peri-implant cortical bone.
The results of this finite element method study demonstrated that insertion torque could serve as a reliable indicator of the strain level in the peri-implant cortical bone resulting from mini-implant insertion.
•Microimplant insertion strain was higher than the ultimate strength of bone.•The damage zone in cortical bone was approximately one-half of the microimplant diameter.•Correlations were found between insertion torque values and 3 strain parameters.•Parameters were average and peak insertion strain and size of the damage zone.</description><subject>Dental Implantation, Endosseous - adverse effects</subject><subject>Dental Implants</subject><subject>Finite Element Analysis</subject><subject>Humans</subject><subject>Maxilla</subject><subject>Orthodontic Anchorage Procedures</subject><subject>Torque</subject><issn>0889-5406</issn><issn>1097-6752</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNp9kc9u1DAQxi1ERZfCEyAhH7kkjB0ndpA4VKsWkCpxgbPl2BPwKrEX2wH1CfrauN3SI6eRZn7f_PsIecOgZcCG94fWHKKLLQcOLcgWBH9GdgxG2Qyy58_JDpQam17AcE5e5nwAgFFweEHOOzHwkXdyR-72MSVcTPEx0AnLH8RAfciYHjIlpl8bUhMcPWLyjV-PiwmFTjEgzSUZH6jbkg8_aC1YXLEW40xjKj_rbqF4S1cfnoT5A72kc00UpLic8Fw2d_uKnM1myfj6MV6Q79dX3_afm5uvn77sL28a2_VjaZiZOoeTnMDgyHolrZgHMQppmFJKgOST6nrB0KEQ3HE7MdMzwRgMlgvsuwvy7tT3mGK9LBe9-mxxqcth3LLmvapPUpyJinYn1KaYc8JZH5NfTbrVDPS9A_qgHxzQ9w5okLo6UFVvHwds04ruSfPv5RX4eAKwnvnbY9LZegwWnU9oi3bR_3fAX0EsmsQ</recordid><startdate>202202</startdate><enddate>202202</enddate><creator>Hung, Bui Quang</creator><creator>Yu, Wonjae</creator><creator>Park, Hyo-Sang</creator><creator>Kyung, Hee-Moon</creator><creator>Hong, Mihee</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>202202</creationdate><title>Correlation between insertion torque and peri-implant bone strain during placement of orthodontic mini-implants: A finite element study</title><author>Hung, Bui Quang ; Yu, Wonjae ; Park, Hyo-Sang ; Kyung, Hee-Moon ; Hong, Mihee</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c359t-1ab3deb7b0ae91587c4f64947a18884072b83541ede442d2cb1a5141106c24e53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Dental Implantation, Endosseous - adverse effects</topic><topic>Dental Implants</topic><topic>Finite Element Analysis</topic><topic>Humans</topic><topic>Maxilla</topic><topic>Orthodontic Anchorage Procedures</topic><topic>Torque</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hung, Bui Quang</creatorcontrib><creatorcontrib>Yu, Wonjae</creatorcontrib><creatorcontrib>Park, Hyo-Sang</creatorcontrib><creatorcontrib>Kyung, Hee-Moon</creatorcontrib><creatorcontrib>Hong, Mihee</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>American journal of orthodontics and dentofacial orthopedics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hung, Bui Quang</au><au>Yu, Wonjae</au><au>Park, Hyo-Sang</au><au>Kyung, Hee-Moon</au><au>Hong, Mihee</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Correlation between insertion torque and peri-implant bone strain during placement of orthodontic mini-implants: A finite element study</atitle><jtitle>American journal of orthodontics and dentofacial orthopedics</jtitle><addtitle>Am J Orthod Dentofacial Orthop</addtitle><date>2022-02</date><risdate>2022</risdate><volume>161</volume><issue>2</issue><spage>248</spage><epage>254</epage><pages>248-254</pages><issn>0889-5406</issn><eissn>1097-6752</eissn><abstract>Insertion torque is the amount of torque exerted on the implant to tighten into the bone. We investigated whether insertion torque values could be correlated with the strain level in the peri-implant cortical bone resulting from mini-implant insertion.
The insertion of a standard size mini-implant (φ 1.4 mm × 7 mm) into maxillary alveolar bone was simulated using the finite element method. A total of 3600 calculation steps were employed to numerically reproduce the mini-implant insertion process and analyze the insertion torque and strain distribution in bone. Special attention was given to the relationship between insertion torque values and strain level in the cortical bone at the final tightening. The strain level was quantified using the following 3 strain parameters: (1) average insertion strain, (2) peak insertion strain recorded near the mini-implant thread tips, and (3) the size of the damage zone in the cortical bone. Correlations between the insertion torque values and these 3 parameters were analyzed using linear regression.
Direct proportionality and strong correlation were found between the insertion torque values and each of the 3 strain parameters: average insertion strain (r2 = 0.91), peak insertion strain (r2 = 0.91), and the size of damage zone (r2 = 0.90) in the peri-implant cortical bone.
The results of this finite element method study demonstrated that insertion torque could serve as a reliable indicator of the strain level in the peri-implant cortical bone resulting from mini-implant insertion.
•Microimplant insertion strain was higher than the ultimate strength of bone.•The damage zone in cortical bone was approximately one-half of the microimplant diameter.•Correlations were found between insertion torque values and 3 strain parameters.•Parameters were average and peak insertion strain and size of the damage zone.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>34629237</pmid><doi>10.1016/j.ajodo.2020.07.042</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0889-5406 |
ispartof | American journal of orthodontics and dentofacial orthopedics, 2022-02, Vol.161 (2), p.248-254 |
issn | 0889-5406 1097-6752 |
language | eng |
recordid | cdi_proquest_miscellaneous_2580948214 |
source | Elsevier |
subjects | Dental Implantation, Endosseous - adverse effects Dental Implants Finite Element Analysis Humans Maxilla Orthodontic Anchorage Procedures Torque |
title | Correlation between insertion torque and peri-implant bone strain during placement of orthodontic mini-implants: A finite element study |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T18%3A09%3A12IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Correlation%20between%20insertion%20torque%20and%20peri-implant%20bone%20strain%20during%20placement%20of%20orthodontic%20mini-implants:%20A%20finite%20element%20study&rft.jtitle=American%20journal%20of%20orthodontics%20and%20dentofacial%20orthopedics&rft.au=Hung,%20Bui%20Quang&rft.date=2022-02&rft.volume=161&rft.issue=2&rft.spage=248&rft.epage=254&rft.pages=248-254&rft.issn=0889-5406&rft.eissn=1097-6752&rft_id=info:doi/10.1016/j.ajodo.2020.07.042&rft_dat=%3Cproquest_cross%3E2580948214%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c359t-1ab3deb7b0ae91587c4f64947a18884072b83541ede442d2cb1a5141106c24e53%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2580948214&rft_id=info:pmid/34629237&rfr_iscdi=true |