Loading…

Usefulness of Multisite Ventricular Pacing in Nonresponders to Cardiac Resynchronization Therapy

Cardiac resynchronization therapy (CRT) is an established treatment for heart failure patients with myocardial dysfunction and delayed ventricular activation, but approximately 25% to 40% of patients do not respond to CRT. Left ventricular (LV) multisite pacing (MSP) has been proposed as a tool to i...

Full description

Saved in:
Bibliographic Details
Published in:The American journal of cardiology 2022-02, Vol.164, p.86-92
Main Authors: Saba, Samir, Nair, Devi, Ellis, Christopher R., Ciuffo, Allen, Cox, Marilyn, Gupta, Nigel, Sharma, Saumya, Jain, Sandeep, Winner, Marshall, Mehta, Sharda, Simon, Torri, Stein, Ken, Ellenbogen, Kenneth A.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Cardiac resynchronization therapy (CRT) is an established treatment for heart failure patients with myocardial dysfunction and delayed ventricular activation, but approximately 25% to 40% of patients do not respond to CRT. Left ventricular (LV) multisite pacing (MSP) has been proposed as a tool to improve CRT response. The goal of this study is to examine the safety and efficacy of LV MSP in CRT nonresponders. Between January 2018, and September 2019, the Strategic Management to Improve CRT Using Multi-Site Pacing trial prospectively enrolled 584 CRT-defibrillator recipients for established indications at 52 sites across the United States and evaluated their response at 6 months using the clinical composite score (CCS). Of the nonresponders, 102 patients had the LV MSP feature turned on and 78 patients completed the 12-month CCS evaluation. The LV MSP feature-related complication-free rate was 99.0% with a lower 95% confidence interval limit of 94.9%, which was higher than the performance goal of 90%. The proportion of nonresponders with an improved CCS from 6 to 12 months was 51.3% with a lower 95% confidence interval limit of 41.4%, which was higher than the performance goal of 5%. The estimated mean reduction in battery longevity with the LV MSP feature was about 3.6 months (estimated battery longevity of 8.87 ± 2.08 years at 6 months and 8.07 ± 2.23 years at 12 months). In conclusion, in CRT nonresponders, the use of the LV MSP feature is safe and associated with a ∼50% conversion rate with a small projected reduction in CRT-defibrillator battery longevity. LV MSP should be considered in the management of CRT nonresponders.
ISSN:0002-9149
1879-1913