Loading…

Fast rise time X-ray pre-ionization source using a corona plasma cathode

X-ray pulses with rise times shorter than 10 ns and high peak power have been generated using a corona plasma cathode as a fast low-inductance switch. The x-ray generator has been developed as a preionization source for a XeCl laser system and can be used at a repetition rate of a few hundred hertz....

Full description

Saved in:
Bibliographic Details
Published in:Journal of physics. D, Applied physics Applied physics, 1993-03, Vol.26 (3), p.404-409
Main Author: Goor, F A van
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c292t-4d5a2c90d46f1369d3263656137b76b59e16b6a0f078891056a8aed820e66bd43
cites cdi_FETCH-LOGICAL-c292t-4d5a2c90d46f1369d3263656137b76b59e16b6a0f078891056a8aed820e66bd43
container_end_page 409
container_issue 3
container_start_page 404
container_title Journal of physics. D, Applied physics
container_volume 26
creator Goor, F A van
description X-ray pulses with rise times shorter than 10 ns and high peak power have been generated using a corona plasma cathode as a fast low-inductance switch. The x-ray generator has been developed as a preionization source for a XeCl laser system and can be used at a repetition rate of a few hundred hertz. A technique to determine the electron density produced by the preionizer is also described. (Original abstract)
doi_str_mv 10.1088/0022-3727/26/3/009
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_26034452</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>26034452</sourcerecordid><originalsourceid>FETCH-LOGICAL-c292t-4d5a2c90d46f1369d3263656137b76b59e16b6a0f078891056a8aed820e66bd43</originalsourceid><addsrcrecordid>eNp9kEtLxDAUhYMoOD7-gKssRHARJ482TZcyOI4w4EbBXbhNU420TU3axfjrzTDDbAZcXQ73O4fDQeiG0QdGlZpTyjkRBS_mXM5FkuUJmjEhGZGZFKdodgDO0UWM35TSXCo2Q6slxBEHFy0eXWfxBwmwwUOwxPne_cKYDo5-CsbiKbr-EwM2Pvge8NBC7JKC8cvX9gqdNdBGe72_l-h9-fS2WJH16_PL4nFNDC_5SLI6B25KWmeySf3KWnApZC6ZKKpCVnlpmawk0IYWSpUstQQFtlacWimrOhOX6G6XOwT_M9k46s5FY9sWeuunqLmkIstynkC-A03wMQbb6CG4DsJGM6q3o-ntJnq7STJpkWSZTLf7dIgG2iZAb1w8ODOpCk63Je53mPPD4Xkcp4e6SSw5Zv-p8AfOg4TB</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>26034452</pqid></control><display><type>article</type><title>Fast rise time X-ray pre-ionization source using a corona plasma cathode</title><source>Institute of Physics</source><source>Institute of Physics:Jisc Collections:IOP Publishing Journal Archive 1874-1998 (access period 2020 to 2024)</source><creator>Goor, F A van</creator><creatorcontrib>Goor, F A van</creatorcontrib><description>X-ray pulses with rise times shorter than 10 ns and high peak power have been generated using a corona plasma cathode as a fast low-inductance switch. The x-ray generator has been developed as a preionization source for a XeCl laser system and can be used at a repetition rate of a few hundred hertz. A technique to determine the electron density produced by the preionizer is also described. (Original abstract)</description><identifier>ISSN: 0022-3727</identifier><identifier>EISSN: 1361-6463</identifier><identifier>DOI: 10.1088/0022-3727/26/3/009</identifier><identifier>CODEN: JPAPBE</identifier><language>eng</language><publisher>Bristol: IOP Publishing</publisher><subject>Electric discharges ; Exact sciences and technology ; Physics ; Physics of gases, plasmas and electric discharges ; Physics of plasmas and electric discharges</subject><ispartof>Journal of physics. D, Applied physics, 1993-03, Vol.26 (3), p.404-409</ispartof><rights>1993 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c292t-4d5a2c90d46f1369d3263656137b76b59e16b6a0f078891056a8aed820e66bd43</citedby><cites>FETCH-LOGICAL-c292t-4d5a2c90d46f1369d3263656137b76b59e16b6a0f078891056a8aed820e66bd43</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/0022-3727/26/3/009/pdf$$EPDF$$P50$$Giop$$H</linktopdf><link.rule.ids>314,778,782,27907,27908,53933</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=4687204$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Goor, F A van</creatorcontrib><title>Fast rise time X-ray pre-ionization source using a corona plasma cathode</title><title>Journal of physics. D, Applied physics</title><description>X-ray pulses with rise times shorter than 10 ns and high peak power have been generated using a corona plasma cathode as a fast low-inductance switch. The x-ray generator has been developed as a preionization source for a XeCl laser system and can be used at a repetition rate of a few hundred hertz. A technique to determine the electron density produced by the preionizer is also described. (Original abstract)</description><subject>Electric discharges</subject><subject>Exact sciences and technology</subject><subject>Physics</subject><subject>Physics of gases, plasmas and electric discharges</subject><subject>Physics of plasmas and electric discharges</subject><issn>0022-3727</issn><issn>1361-6463</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1993</creationdate><recordtype>article</recordtype><recordid>eNp9kEtLxDAUhYMoOD7-gKssRHARJ482TZcyOI4w4EbBXbhNU420TU3axfjrzTDDbAZcXQ73O4fDQeiG0QdGlZpTyjkRBS_mXM5FkuUJmjEhGZGZFKdodgDO0UWM35TSXCo2Q6slxBEHFy0eXWfxBwmwwUOwxPne_cKYDo5-CsbiKbr-EwM2Pvge8NBC7JKC8cvX9gqdNdBGe72_l-h9-fS2WJH16_PL4nFNDC_5SLI6B25KWmeySf3KWnApZC6ZKKpCVnlpmawk0IYWSpUstQQFtlacWimrOhOX6G6XOwT_M9k46s5FY9sWeuunqLmkIstynkC-A03wMQbb6CG4DsJGM6q3o-ntJnq7STJpkWSZTLf7dIgG2iZAb1w8ODOpCk63Je53mPPD4Xkcp4e6SSw5Zv-p8AfOg4TB</recordid><startdate>19930314</startdate><enddate>19930314</enddate><creator>Goor, F A van</creator><general>IOP Publishing</general><general>Institute of Physics</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>F28</scope><scope>FR3</scope></search><sort><creationdate>19930314</creationdate><title>Fast rise time X-ray pre-ionization source using a corona plasma cathode</title><author>Goor, F A van</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c292t-4d5a2c90d46f1369d3263656137b76b59e16b6a0f078891056a8aed820e66bd43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1993</creationdate><topic>Electric discharges</topic><topic>Exact sciences and technology</topic><topic>Physics</topic><topic>Physics of gases, plasmas and electric discharges</topic><topic>Physics of plasmas and electric discharges</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Goor, F A van</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><jtitle>Journal of physics. D, Applied physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Goor, F A van</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Fast rise time X-ray pre-ionization source using a corona plasma cathode</atitle><jtitle>Journal of physics. D, Applied physics</jtitle><date>1993-03-14</date><risdate>1993</risdate><volume>26</volume><issue>3</issue><spage>404</spage><epage>409</epage><pages>404-409</pages><issn>0022-3727</issn><eissn>1361-6463</eissn><coden>JPAPBE</coden><abstract>X-ray pulses with rise times shorter than 10 ns and high peak power have been generated using a corona plasma cathode as a fast low-inductance switch. The x-ray generator has been developed as a preionization source for a XeCl laser system and can be used at a repetition rate of a few hundred hertz. A technique to determine the electron density produced by the preionizer is also described. (Original abstract)</abstract><cop>Bristol</cop><pub>IOP Publishing</pub><doi>10.1088/0022-3727/26/3/009</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0022-3727
ispartof Journal of physics. D, Applied physics, 1993-03, Vol.26 (3), p.404-409
issn 0022-3727
1361-6463
language eng
recordid cdi_proquest_miscellaneous_26034452
source Institute of Physics; Institute of Physics:Jisc Collections:IOP Publishing Journal Archive 1874-1998 (access period 2020 to 2024)
subjects Electric discharges
Exact sciences and technology
Physics
Physics of gases, plasmas and electric discharges
Physics of plasmas and electric discharges
title Fast rise time X-ray pre-ionization source using a corona plasma cathode
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-16T10%3A10%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Fast%20rise%20time%20X-ray%20pre-ionization%20source%20using%20a%20corona%20plasma%20cathode&rft.jtitle=Journal%20of%20physics.%20D,%20Applied%20physics&rft.au=Goor,%20F%20A%20van&rft.date=1993-03-14&rft.volume=26&rft.issue=3&rft.spage=404&rft.epage=409&rft.pages=404-409&rft.issn=0022-3727&rft.eissn=1361-6463&rft.coden=JPAPBE&rft_id=info:doi/10.1088/0022-3727/26/3/009&rft_dat=%3Cproquest_cross%3E26034452%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c292t-4d5a2c90d46f1369d3263656137b76b59e16b6a0f078891056a8aed820e66bd43%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=26034452&rft_id=info:pmid/&rfr_iscdi=true