Velocity measurements in 3D turbulent flows by means of a rotating X-wire probe
One of the problems encountered in 3D turbulent flow measurement when using a four-wire probe is that the equation system is overdetermined, leading to many errors. Discusses a method of resolution for this problem by means of a rotating X-wire probe, and defines a well determined 6 x 6 matrix syste...
Saved in:
Published in: | Measurement science & technology 1995-06, Vol.6 (6), p.843-850 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | One of the problems encountered in 3D turbulent flow measurement when using a four-wire probe is that the equation system is overdetermined, leading to many errors. Discusses a method of resolution for this problem by means of a rotating X-wire probe, and defines a well determined 6 x 6 matrix system in order to obtain an accurate solution. (Original abstract-amended) |
---|---|
ISSN: | 0957-0233 1361-6501 |
DOI: | 10.1088/0957-0233/6/6/021 |