Loading…
Clinical evaluation of two adult oxygenator systems in terms of mortality and major adverse events
Purpose The primary aim of this study was to examine the effects of two oxygenator systems on major adverse events and mortality. Methods A total of 181 consecutive patients undergoing coronary artery bypass grafting in our clinic were retrospectively analyzed. The patients were divided into two gro...
Saved in:
Published in: | Perfusion 2023-04, Vol.38 (3), p.515-522 |
---|---|
Main Authors: | , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Purpose
The primary aim of this study was to examine the effects of two oxygenator systems on major adverse events and mortality.
Methods
A total of 181 consecutive patients undergoing coronary artery bypass grafting in our clinic were retrospectively analyzed. The patients were divided into two groups according to the oxygenator used: Group M, in which a Medtronic Affinity (Medtronic Operational Headquarters, Minneapolis, MN, USA) oxygenator was used, and Group S, in which a Sorin Inspire (Sorin Group Italia, Mirandola, Italy) oxygenator was used.
Results
Group S consisted of 89 patients, whereas Group M included 92 patients. No statistically significant differences were found between the two groups in terms of age (p = .112), weight (p = .465), body surface area (p = .956), or gender (p = .484). There was no statistically significant difference in hemorrhage on the first or second postoperative day (p = .318 and p = .455, respectively). No statistically significant differences were observed in terms of red blood cell (p = .468), fresh frozen plasma (p = .116), or platelet concentrate transfusion (p = .212). Infections, wound complications, and delayed sternal closure were significantly more common in Group M (p = .006, p = .023, and p = .019, respectively). Extracorporeal membrane oxygenators and intra-aortic balloon pumps were required significantly more frequently in Group S (p = .025 and p = .013, respectively). Major adverse events occurred in 16 (18%) patients in Group S and 14 (15.2%) patients in Group M (p = .382). Mortality was observed in six (6.7%) patients in Group S and three (3.3%) patients in Group M (p = .232). No statistically significant difference was found between the two groups in terms of length of hospital stay (p = .451).
Conclusion
The clinical outcomes of the two oxygenator systems, including mortality, major adverse events, hemorrhage, erythrocyte and platelet transfusions, and length of hospital stay, were similar. |
---|---|
ISSN: | 0267-6591 1477-111X |
DOI: | 10.1177/02676591211063830 |