Loading…

Monte Carlo calculated beam quality correction factors for two cylindrical ionization chambers in photon beams

•Clinical dosimetry in radiotherapy is based on ion chambers.•To calculate the dose, the beam quality correction factor kQ is necessary.•kQ factors were calculated by Monte Carlo simulations using EGSnrc.•for two widely used ion chambers kQ was calculated the first time. Although several studies pro...

Full description

Saved in:
Bibliographic Details
Published in:Physica medica 2022-02, Vol.94, p.17-23
Main Authors: Alissa, Mohamad, Zink, Klemens, Tessier, Frédéric, Schoenfeld, Andreas A., Czarnecki, Damian
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c400t-11dda1a8c13f2caf51e92f928019013f3340ff1e8ca2014d283ab5143267115f3
cites cdi_FETCH-LOGICAL-c400t-11dda1a8c13f2caf51e92f928019013f3340ff1e8ca2014d283ab5143267115f3
container_end_page 23
container_issue
container_start_page 17
container_title Physica medica
container_volume 94
creator Alissa, Mohamad
Zink, Klemens
Tessier, Frédéric
Schoenfeld, Andreas A.
Czarnecki, Damian
description •Clinical dosimetry in radiotherapy is based on ion chambers.•To calculate the dose, the beam quality correction factor kQ is necessary.•kQ factors were calculated by Monte Carlo simulations using EGSnrc.•for two widely used ion chambers kQ was calculated the first time. Although several studies provide data for reference dosimetry, the SNC600c and SNC125c ionization chambers (Sun Nuclear Corporation, Melbourne, FL) are in clinical use worldwide for which no beam quality correction factors kQ are available. The goal of this study was to calculate beam quality correction factors kQ for these ionization chambers according to dosimetry protocols TG-51, TRS 398 and DIN 6800-2. Monte Carlo simulations using EGSnrc have been performed to calculate the absorbed dose to water and the dose to air within the active volume of ionization chamber models. Both spectra and simulations of beam transport through linear accelerator head models were used as radiation sources for the Monte Carlo calculations. kQ values as a function of the respective beam quality specifier Q were fitted against recommended equations for photon beam dosimetry in the range of 4 MV to 25 MV. The fitting curves through the calculated values showed a root mean square deviation between 0.0010 and 0.0017. The investigated ionization chamber models (SNC600c, SNC125c) are not included in above mentioned dosimetry protocols, but are in clinical use worldwide. This study covered this knowledge gap and compared the calculated results with published kQ values for similar ionization chambers. Agreements with published data were observed in the 95% confidence interval, confirming the use of data for similar ionization chambers, when there are no kQ values available for a given ionization chamber.
doi_str_mv 10.1016/j.ejmp.2021.12.012
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2615922063</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1120179721003653</els_id><sourcerecordid>2615922063</sourcerecordid><originalsourceid>FETCH-LOGICAL-c400t-11dda1a8c13f2caf51e92f928019013f3340ff1e8ca2014d283ab5143267115f3</originalsourceid><addsrcrecordid>eNp9kD2P1DAQhi0E4j7gD1AglzQJM-Nks5Fo0OrgkA7RgERneZ2xzqsk3rMd0PLrcdiDkmpG4-d9JT9CvEKoEXDz9lDzYTrWBIQ1Ug1IT8QldtRU2OP3p2VHggq7vrsQVykdABRR2z4XF6rpO4IOLsX8OcyZ5c7EMUhrRruMJvMg92wm-bCY0eeTtCFGttmHWTpjc4hJuhBl_lkip9HPQ_QlKsu7_2X-YPbeTHsunJ_l8T7kclob0wvxzJkx8cvHeS2-fbj5urut7r58_LR7f1fZBiBXiMNg0GwtKkfWuBa5J9fTFrCHclOqAeeQt9YQYDPQVpl9i42iTYfYOnUt3px7jzE8LJyynnyyPI5m5rAkTRtseyLYqILSGbUxpBTZ6WP0k4knjaBXz_qgV8969ayRdPFcQq8f-5f9xMO_yF-xBXh3Brj88ofnqJP1PFse_KpSD8H_r_830MWPzQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2615922063</pqid></control><display><type>article</type><title>Monte Carlo calculated beam quality correction factors for two cylindrical ionization chambers in photon beams</title><source>Elsevier</source><creator>Alissa, Mohamad ; Zink, Klemens ; Tessier, Frédéric ; Schoenfeld, Andreas A. ; Czarnecki, Damian</creator><creatorcontrib>Alissa, Mohamad ; Zink, Klemens ; Tessier, Frédéric ; Schoenfeld, Andreas A. ; Czarnecki, Damian</creatorcontrib><description>•Clinical dosimetry in radiotherapy is based on ion chambers.•To calculate the dose, the beam quality correction factor kQ is necessary.•kQ factors were calculated by Monte Carlo simulations using EGSnrc.•for two widely used ion chambers kQ was calculated the first time. Although several studies provide data for reference dosimetry, the SNC600c and SNC125c ionization chambers (Sun Nuclear Corporation, Melbourne, FL) are in clinical use worldwide for which no beam quality correction factors kQ are available. The goal of this study was to calculate beam quality correction factors kQ for these ionization chambers according to dosimetry protocols TG-51, TRS 398 and DIN 6800-2. Monte Carlo simulations using EGSnrc have been performed to calculate the absorbed dose to water and the dose to air within the active volume of ionization chamber models. Both spectra and simulations of beam transport through linear accelerator head models were used as radiation sources for the Monte Carlo calculations. kQ values as a function of the respective beam quality specifier Q were fitted against recommended equations for photon beam dosimetry in the range of 4 MV to 25 MV. The fitting curves through the calculated values showed a root mean square deviation between 0.0010 and 0.0017. The investigated ionization chamber models (SNC600c, SNC125c) are not included in above mentioned dosimetry protocols, but are in clinical use worldwide. This study covered this knowledge gap and compared the calculated results with published kQ values for similar ionization chambers. Agreements with published data were observed in the 95% confidence interval, confirming the use of data for similar ionization chambers, when there are no kQ values available for a given ionization chamber.</description><identifier>ISSN: 1120-1797</identifier><identifier>EISSN: 1724-191X</identifier><identifier>DOI: 10.1016/j.ejmp.2021.12.012</identifier><identifier>PMID: 34972070</identifier><language>eng</language><publisher>Italy: Elsevier Ltd</publisher><subject>Beam quality correction factor ; Dosimetry ; Ionization chamber ; Monte Carlo Method ; Monte Carlo simulation ; MV photon beams ; Particle Accelerators ; Photons ; Radiometry ; Relative Biological Effectiveness ; Water</subject><ispartof>Physica medica, 2022-02, Vol.94, p.17-23</ispartof><rights>2022 Associazione Italiana di Fisica Medica e Sanitaria</rights><rights>Copyright © 2022 Associazione Italiana di Fisica Medica e Sanitaria. Published by Elsevier Ltd. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c400t-11dda1a8c13f2caf51e92f928019013f3340ff1e8ca2014d283ab5143267115f3</citedby><cites>FETCH-LOGICAL-c400t-11dda1a8c13f2caf51e92f928019013f3340ff1e8ca2014d283ab5143267115f3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/34972070$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Alissa, Mohamad</creatorcontrib><creatorcontrib>Zink, Klemens</creatorcontrib><creatorcontrib>Tessier, Frédéric</creatorcontrib><creatorcontrib>Schoenfeld, Andreas A.</creatorcontrib><creatorcontrib>Czarnecki, Damian</creatorcontrib><title>Monte Carlo calculated beam quality correction factors for two cylindrical ionization chambers in photon beams</title><title>Physica medica</title><addtitle>Phys Med</addtitle><description>•Clinical dosimetry in radiotherapy is based on ion chambers.•To calculate the dose, the beam quality correction factor kQ is necessary.•kQ factors were calculated by Monte Carlo simulations using EGSnrc.•for two widely used ion chambers kQ was calculated the first time. Although several studies provide data for reference dosimetry, the SNC600c and SNC125c ionization chambers (Sun Nuclear Corporation, Melbourne, FL) are in clinical use worldwide for which no beam quality correction factors kQ are available. The goal of this study was to calculate beam quality correction factors kQ for these ionization chambers according to dosimetry protocols TG-51, TRS 398 and DIN 6800-2. Monte Carlo simulations using EGSnrc have been performed to calculate the absorbed dose to water and the dose to air within the active volume of ionization chamber models. Both spectra and simulations of beam transport through linear accelerator head models were used as radiation sources for the Monte Carlo calculations. kQ values as a function of the respective beam quality specifier Q were fitted against recommended equations for photon beam dosimetry in the range of 4 MV to 25 MV. The fitting curves through the calculated values showed a root mean square deviation between 0.0010 and 0.0017. The investigated ionization chamber models (SNC600c, SNC125c) are not included in above mentioned dosimetry protocols, but are in clinical use worldwide. This study covered this knowledge gap and compared the calculated results with published kQ values for similar ionization chambers. Agreements with published data were observed in the 95% confidence interval, confirming the use of data for similar ionization chambers, when there are no kQ values available for a given ionization chamber.</description><subject>Beam quality correction factor</subject><subject>Dosimetry</subject><subject>Ionization chamber</subject><subject>Monte Carlo Method</subject><subject>Monte Carlo simulation</subject><subject>MV photon beams</subject><subject>Particle Accelerators</subject><subject>Photons</subject><subject>Radiometry</subject><subject>Relative Biological Effectiveness</subject><subject>Water</subject><issn>1120-1797</issn><issn>1724-191X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNp9kD2P1DAQhi0E4j7gD1AglzQJM-Nks5Fo0OrgkA7RgERneZ2xzqsk3rMd0PLrcdiDkmpG4-d9JT9CvEKoEXDz9lDzYTrWBIQ1Ug1IT8QldtRU2OP3p2VHggq7vrsQVykdABRR2z4XF6rpO4IOLsX8OcyZ5c7EMUhrRruMJvMg92wm-bCY0eeTtCFGttmHWTpjc4hJuhBl_lkip9HPQ_QlKsu7_2X-YPbeTHsunJ_l8T7kclob0wvxzJkx8cvHeS2-fbj5urut7r58_LR7f1fZBiBXiMNg0GwtKkfWuBa5J9fTFrCHclOqAeeQt9YQYDPQVpl9i42iTYfYOnUt3px7jzE8LJyynnyyPI5m5rAkTRtseyLYqILSGbUxpBTZ6WP0k4knjaBXz_qgV8969ayRdPFcQq8f-5f9xMO_yF-xBXh3Brj88ofnqJP1PFse_KpSD8H_r_830MWPzQ</recordid><startdate>202202</startdate><enddate>202202</enddate><creator>Alissa, Mohamad</creator><creator>Zink, Klemens</creator><creator>Tessier, Frédéric</creator><creator>Schoenfeld, Andreas A.</creator><creator>Czarnecki, Damian</creator><general>Elsevier Ltd</general><scope>6I.</scope><scope>AAFTH</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>202202</creationdate><title>Monte Carlo calculated beam quality correction factors for two cylindrical ionization chambers in photon beams</title><author>Alissa, Mohamad ; Zink, Klemens ; Tessier, Frédéric ; Schoenfeld, Andreas A. ; Czarnecki, Damian</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c400t-11dda1a8c13f2caf51e92f928019013f3340ff1e8ca2014d283ab5143267115f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Beam quality correction factor</topic><topic>Dosimetry</topic><topic>Ionization chamber</topic><topic>Monte Carlo Method</topic><topic>Monte Carlo simulation</topic><topic>MV photon beams</topic><topic>Particle Accelerators</topic><topic>Photons</topic><topic>Radiometry</topic><topic>Relative Biological Effectiveness</topic><topic>Water</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Alissa, Mohamad</creatorcontrib><creatorcontrib>Zink, Klemens</creatorcontrib><creatorcontrib>Tessier, Frédéric</creatorcontrib><creatorcontrib>Schoenfeld, Andreas A.</creatorcontrib><creatorcontrib>Czarnecki, Damian</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Physica medica</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Alissa, Mohamad</au><au>Zink, Klemens</au><au>Tessier, Frédéric</au><au>Schoenfeld, Andreas A.</au><au>Czarnecki, Damian</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Monte Carlo calculated beam quality correction factors for two cylindrical ionization chambers in photon beams</atitle><jtitle>Physica medica</jtitle><addtitle>Phys Med</addtitle><date>2022-02</date><risdate>2022</risdate><volume>94</volume><spage>17</spage><epage>23</epage><pages>17-23</pages><issn>1120-1797</issn><eissn>1724-191X</eissn><abstract>•Clinical dosimetry in radiotherapy is based on ion chambers.•To calculate the dose, the beam quality correction factor kQ is necessary.•kQ factors were calculated by Monte Carlo simulations using EGSnrc.•for two widely used ion chambers kQ was calculated the first time. Although several studies provide data for reference dosimetry, the SNC600c and SNC125c ionization chambers (Sun Nuclear Corporation, Melbourne, FL) are in clinical use worldwide for which no beam quality correction factors kQ are available. The goal of this study was to calculate beam quality correction factors kQ for these ionization chambers according to dosimetry protocols TG-51, TRS 398 and DIN 6800-2. Monte Carlo simulations using EGSnrc have been performed to calculate the absorbed dose to water and the dose to air within the active volume of ionization chamber models. Both spectra and simulations of beam transport through linear accelerator head models were used as radiation sources for the Monte Carlo calculations. kQ values as a function of the respective beam quality specifier Q were fitted against recommended equations for photon beam dosimetry in the range of 4 MV to 25 MV. The fitting curves through the calculated values showed a root mean square deviation between 0.0010 and 0.0017. The investigated ionization chamber models (SNC600c, SNC125c) are not included in above mentioned dosimetry protocols, but are in clinical use worldwide. This study covered this knowledge gap and compared the calculated results with published kQ values for similar ionization chambers. Agreements with published data were observed in the 95% confidence interval, confirming the use of data for similar ionization chambers, when there are no kQ values available for a given ionization chamber.</abstract><cop>Italy</cop><pub>Elsevier Ltd</pub><pmid>34972070</pmid><doi>10.1016/j.ejmp.2021.12.012</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1120-1797
ispartof Physica medica, 2022-02, Vol.94, p.17-23
issn 1120-1797
1724-191X
language eng
recordid cdi_proquest_miscellaneous_2615922063
source Elsevier
subjects Beam quality correction factor
Dosimetry
Ionization chamber
Monte Carlo Method
Monte Carlo simulation
MV photon beams
Particle Accelerators
Photons
Radiometry
Relative Biological Effectiveness
Water
title Monte Carlo calculated beam quality correction factors for two cylindrical ionization chambers in photon beams
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T05%3A48%3A56IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Monte%20Carlo%20calculated%20beam%20quality%20correction%20factors%20for%20two%20cylindrical%20ionization%20chambers%20in%20photon%20beams&rft.jtitle=Physica%20medica&rft.au=Alissa,%20Mohamad&rft.date=2022-02&rft.volume=94&rft.spage=17&rft.epage=23&rft.pages=17-23&rft.issn=1120-1797&rft.eissn=1724-191X&rft_id=info:doi/10.1016/j.ejmp.2021.12.012&rft_dat=%3Cproquest_cross%3E2615922063%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c400t-11dda1a8c13f2caf51e92f928019013f3340ff1e8ca2014d283ab5143267115f3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2615922063&rft_id=info:pmid/34972070&rfr_iscdi=true