Electrothermal atomizer laser-excited atomic fluorescence spectrometry for the determination of phosphorus in polymers by direct solid analysis and dissolution

Electrothermal atomizer laser-excited atomic fluorescence spectrometry (ETA-LEAFS) with direct solid analysis was used to measure phosphorus in polymers that consisted mainly of poly (ethylene terephthalate). The ETA-LEAFS detection limit for phosphorus was 8 pg, and the linear dynamic range extende...

Full description

Saved in:
Bibliographic Details
Published in:Journal of analytical atomic spectrometry 1996, Vol.11 (4), p.279-285
Main Authors: LONARDO, R. F, YUZEFOVSKY, A. I, YANG, K. X, MICHEL, R. G, FRAME, E. S, BARREN, J
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c383t-fc823677fc9092d7f6a03d8ebff128260be809e331cb304f3b8467e49f5e50fb3
cites
container_end_page 285
container_issue 4
container_start_page 279
container_title Journal of analytical atomic spectrometry
container_volume 11
creator LONARDO, R. F
YUZEFOVSKY, A. I
YANG, K. X
MICHEL, R. G
FRAME, E. S
BARREN, J
description Electrothermal atomizer laser-excited atomic fluorescence spectrometry (ETA-LEAFS) with direct solid analysis was used to measure phosphorus in polymers that consisted mainly of poly (ethylene terephthalate). The ETA-LEAFS detection limit for phosphorus was 8 pg, and the linear dynamic range extended over about five orders of magnitude. Electrothermal atomic absorption spectrometry and inductively coupled plasma atomic emission spectrometry were used to validate quantitative results obtained. A novel dissolution method that utilized trifluoroacetic acid and toluene was used for validation purposes. A comparison was made between the use of ETA-LEAFS and the alternative techniques.
doi_str_mv 10.1039/JA9961100279
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_26178125</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>26178125</sourcerecordid><originalsourceid>FETCH-LOGICAL-c383t-fc823677fc9092d7f6a03d8ebff128260be809e331cb304f3b8467e49f5e50fb3</originalsourceid><addsrcrecordid>eNpFkctq3TAQhkVpoKdJdnkALUpXdaqLbVnLEHIl0E26NrI84uggW65Ghrovk1et0hPSxTDDP_98wzCEXHB2yZnU3x-vtG45Z0wo_YHsuGzrqmnq-iPZMdGqStdKfSKfEQ-MsboRzY683ASwOcW8hzSZQE2Ok_8DiQaDkCr4bX2G8Shb6sIaE6CF2QLF5d_kBDlt1MVEC4OOkAvIzyb7ONPo6LKPWCKtSP1Mlxi2CRLSYaOjTwVAMQZfFswmbOixFGPpYFHXV8QZOXEmIJy_5VPy8_bm-fq-evpx93B99VRZ2clcOdsJ2SrlrGZajMq1hsmxg8E5LjrRsgE6pkFKbgfJaieHrm4V1No10DA3yFPy9chdUvy1AuZ-8uXOEMwMccVetFx1XDTF-O1otCkiJnD9kvxk0tZz1r9-oT-Y_18o9i9vXIPWBJfMbD2-z0imlOik_AvG9oxf</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>26178125</pqid></control><display><type>article</type><title>Electrothermal atomizer laser-excited atomic fluorescence spectrometry for the determination of phosphorus in polymers by direct solid analysis and dissolution</title><source>Royal Society of Chemistry: Jisc Collections: Journals Archive 1841-2007 (2019-2023)</source><creator>LONARDO, R. F ; YUZEFOVSKY, A. I ; YANG, K. X ; MICHEL, R. G ; FRAME, E. S ; BARREN, J</creator><creatorcontrib>LONARDO, R. F ; YUZEFOVSKY, A. I ; YANG, K. X ; MICHEL, R. G ; FRAME, E. S ; BARREN, J</creatorcontrib><description>Electrothermal atomizer laser-excited atomic fluorescence spectrometry (ETA-LEAFS) with direct solid analysis was used to measure phosphorus in polymers that consisted mainly of poly (ethylene terephthalate). The ETA-LEAFS detection limit for phosphorus was 8 pg, and the linear dynamic range extended over about five orders of magnitude. Electrothermal atomic absorption spectrometry and inductively coupled plasma atomic emission spectrometry were used to validate quantitative results obtained. A novel dissolution method that utilized trifluoroacetic acid and toluene was used for validation purposes. A comparison was made between the use of ETA-LEAFS and the alternative techniques.</description><identifier>ISSN: 0267-9477</identifier><identifier>EISSN: 1364-5544</identifier><identifier>DOI: 10.1039/JA9961100279</identifier><identifier>CODEN: JASPE2</identifier><language>eng</language><publisher>Cambridge: Royal Society of Chemistry</publisher><subject>Applied sciences ; Exact sciences and technology ; Organic polymers ; Physicochemistry of polymers ; Properties and characterization ; Structure, morphology and analysis</subject><ispartof>Journal of analytical atomic spectrometry, 1996, Vol.11 (4), p.279-285</ispartof><rights>1996 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c383t-fc823677fc9092d7f6a03d8ebff128260be809e331cb304f3b8467e49f5e50fb3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,4024,27923,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=3077283$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>LONARDO, R. F</creatorcontrib><creatorcontrib>YUZEFOVSKY, A. I</creatorcontrib><creatorcontrib>YANG, K. X</creatorcontrib><creatorcontrib>MICHEL, R. G</creatorcontrib><creatorcontrib>FRAME, E. S</creatorcontrib><creatorcontrib>BARREN, J</creatorcontrib><title>Electrothermal atomizer laser-excited atomic fluorescence spectrometry for the determination of phosphorus in polymers by direct solid analysis and dissolution</title><title>Journal of analytical atomic spectrometry</title><description>Electrothermal atomizer laser-excited atomic fluorescence spectrometry (ETA-LEAFS) with direct solid analysis was used to measure phosphorus in polymers that consisted mainly of poly (ethylene terephthalate). The ETA-LEAFS detection limit for phosphorus was 8 pg, and the linear dynamic range extended over about five orders of magnitude. Electrothermal atomic absorption spectrometry and inductively coupled plasma atomic emission spectrometry were used to validate quantitative results obtained. A novel dissolution method that utilized trifluoroacetic acid and toluene was used for validation purposes. A comparison was made between the use of ETA-LEAFS and the alternative techniques.</description><subject>Applied sciences</subject><subject>Exact sciences and technology</subject><subject>Organic polymers</subject><subject>Physicochemistry of polymers</subject><subject>Properties and characterization</subject><subject>Structure, morphology and analysis</subject><issn>0267-9477</issn><issn>1364-5544</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1996</creationdate><recordtype>article</recordtype><recordid>eNpFkctq3TAQhkVpoKdJdnkALUpXdaqLbVnLEHIl0E26NrI84uggW65Ghrovk1et0hPSxTDDP_98wzCEXHB2yZnU3x-vtG45Z0wo_YHsuGzrqmnq-iPZMdGqStdKfSKfEQ-MsboRzY683ASwOcW8hzSZQE2Ok_8DiQaDkCr4bX2G8Shb6sIaE6CF2QLF5d_kBDlt1MVEC4OOkAvIzyb7ONPo6LKPWCKtSP1Mlxi2CRLSYaOjTwVAMQZfFswmbOixFGPpYFHXV8QZOXEmIJy_5VPy8_bm-fq-evpx93B99VRZ2clcOdsJ2SrlrGZajMq1hsmxg8E5LjrRsgE6pkFKbgfJaieHrm4V1No10DA3yFPy9chdUvy1AuZ-8uXOEMwMccVetFx1XDTF-O1otCkiJnD9kvxk0tZz1r9-oT-Y_18o9i9vXIPWBJfMbD2-z0imlOik_AvG9oxf</recordid><startdate>1996</startdate><enddate>1996</enddate><creator>LONARDO, R. F</creator><creator>YUZEFOVSKY, A. I</creator><creator>YANG, K. X</creator><creator>MICHEL, R. G</creator><creator>FRAME, E. S</creator><creator>BARREN, J</creator><general>Royal Society of Chemistry</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>1996</creationdate><title>Electrothermal atomizer laser-excited atomic fluorescence spectrometry for the determination of phosphorus in polymers by direct solid analysis and dissolution</title><author>LONARDO, R. F ; YUZEFOVSKY, A. I ; YANG, K. X ; MICHEL, R. G ; FRAME, E. S ; BARREN, J</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c383t-fc823677fc9092d7f6a03d8ebff128260be809e331cb304f3b8467e49f5e50fb3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1996</creationdate><topic>Applied sciences</topic><topic>Exact sciences and technology</topic><topic>Organic polymers</topic><topic>Physicochemistry of polymers</topic><topic>Properties and characterization</topic><topic>Structure, morphology and analysis</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>LONARDO, R. F</creatorcontrib><creatorcontrib>YUZEFOVSKY, A. I</creatorcontrib><creatorcontrib>YANG, K. X</creatorcontrib><creatorcontrib>MICHEL, R. G</creatorcontrib><creatorcontrib>FRAME, E. S</creatorcontrib><creatorcontrib>BARREN, J</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Journal of analytical atomic spectrometry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>LONARDO, R. F</au><au>YUZEFOVSKY, A. I</au><au>YANG, K. X</au><au>MICHEL, R. G</au><au>FRAME, E. S</au><au>BARREN, J</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Electrothermal atomizer laser-excited atomic fluorescence spectrometry for the determination of phosphorus in polymers by direct solid analysis and dissolution</atitle><jtitle>Journal of analytical atomic spectrometry</jtitle><date>1996</date><risdate>1996</risdate><volume>11</volume><issue>4</issue><spage>279</spage><epage>285</epage><pages>279-285</pages><issn>0267-9477</issn><eissn>1364-5544</eissn><coden>JASPE2</coden><abstract>Electrothermal atomizer laser-excited atomic fluorescence spectrometry (ETA-LEAFS) with direct solid analysis was used to measure phosphorus in polymers that consisted mainly of poly (ethylene terephthalate). The ETA-LEAFS detection limit for phosphorus was 8 pg, and the linear dynamic range extended over about five orders of magnitude. Electrothermal atomic absorption spectrometry and inductively coupled plasma atomic emission spectrometry were used to validate quantitative results obtained. A novel dissolution method that utilized trifluoroacetic acid and toluene was used for validation purposes. A comparison was made between the use of ETA-LEAFS and the alternative techniques.</abstract><cop>Cambridge</cop><pub>Royal Society of Chemistry</pub><doi>10.1039/JA9961100279</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0267-9477
ispartof Journal of analytical atomic spectrometry, 1996, Vol.11 (4), p.279-285
issn 0267-9477
1364-5544
language eng
recordid cdi_proquest_miscellaneous_26178125
source Royal Society of Chemistry: Jisc Collections: Journals Archive 1841-2007 (2019-2023)
subjects Applied sciences
Exact sciences and technology
Organic polymers
Physicochemistry of polymers
Properties and characterization
Structure, morphology and analysis
title Electrothermal atomizer laser-excited atomic fluorescence spectrometry for the determination of phosphorus in polymers by direct solid analysis and dissolution
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T00%3A06%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Electrothermal%20atomizer%20laser-excited%20atomic%20fluorescence%20spectrometry%20for%20the%20determination%20of%20phosphorus%20in%20polymers%20by%20direct%20solid%20analysis%20and%20dissolution&rft.jtitle=Journal%20of%20analytical%20atomic%20spectrometry&rft.au=LONARDO,%20R.%20F&rft.date=1996&rft.volume=11&rft.issue=4&rft.spage=279&rft.epage=285&rft.pages=279-285&rft.issn=0267-9477&rft.eissn=1364-5544&rft.coden=JASPE2&rft_id=info:doi/10.1039/JA9961100279&rft_dat=%3Cproquest_cross%3E26178125%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c383t-fc823677fc9092d7f6a03d8ebff128260be809e331cb304f3b8467e49f5e50fb3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=26178125&rft_id=info:pmid/&rfr_iscdi=true