Loading…
Estimation of zorifertinib metabolic stability in human liver microsomes using LC–MS/MS
•This is considered the first LC-MS/MS method for ZFB quantification in the HLMs matrix.•ZFB metabolic stability prediction was done using the StarDrop software package (WhichP450 module).•The ZFB metabolic stability including CLint (32.5 µL/min/mg) and in vitro t1/2 (21.33 min).•ZFB showed a modera...
Saved in:
Published in: | Journal of pharmaceutical and biomedical analysis 2022-03, Vol.211, p.114626-114626, Article 114626 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | •This is considered the first LC-MS/MS method for ZFB quantification in the HLMs matrix.•ZFB metabolic stability prediction was done using the StarDrop software package (WhichP450 module).•The ZFB metabolic stability including CLint (32.5 µL/min/mg) and in vitro t1/2 (21.33 min).•ZFB showed a moderate extraction ratio that reveals its good in vivo bioavailability.
Zorifertinib (AZD-3759; ZFB) is a novel, potent, oral, small molecule used to treat non-small cell lung cancer. ZFB is an epidermal growth factor receptor inhibitor that is capable of crossing blood–brain barrier. The in silico metabolic software used for ZFB metabolic stability prediction was the StarDrop software package (WhichP450 module). An LC-MS/MS analytical method (fast and accurate) was established for ZFB quantification in human liver microsomes (HLMs) in order to estimate its metabolic stability. ZFB and encorafenib (ENF) (internal standard; IS) were separated through the use of an isocratic mobile phase system with a C8 stationary phase column. The LC-MS/MS method for ZFB exhibited linearity in the range of 5 ng/mL to 500 ng/mL in HLMs matrix with a linear regression equation: y = 0.2438x - 0.341 (R² = 0.9992). The limit of quantification (LOQ) was 3.78 ng/mL confirming the LC-MS/MS method sensitivity. The inter- and intraday accuracy and precision were less than 9.56% confirming the reproducibility of the LC-MS/MS method. The intrinsic clearance and in vitro half-life of ZFB were 32.5 µL/min/mg and 21.33 min, respectively. ZFB exhibited a moderate extraction ratio that revealed good bioavailability. Literature review demonstrated that the developed analytical method is the first developed LC-MS/MS method for determining ZFB metabolic stability. |
---|---|
ISSN: | 0731-7085 1873-264X |
DOI: | 10.1016/j.jpba.2022.114626 |