Continuous atrial pressure monitoring via steerable guide catheter in transcatheter mitral and tricuspid edge‐to‐edge repair
Transcatheter edge‐to‐edge repair (TEER) has emerged to address severe mitral and tricuspid valve regurgitation in patients who are at high perioperative risk for open‐heart surgery. No clinical data is available for continuous left and right atrial pressure monitoring using the steerable guiding ca...
Saved in:
Published in: | Catheterization and cardiovascular interventions 2022-05, Vol.99 (6), p.1796-1806 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c3889-612d51266187bb0791ff2900d97f3f4ea6529f96076c216230fc4f3601defd53 |
---|---|
cites | cdi_FETCH-LOGICAL-c3889-612d51266187bb0791ff2900d97f3f4ea6529f96076c216230fc4f3601defd53 |
container_end_page | 1806 |
container_issue | 6 |
container_start_page | 1796 |
container_title | Catheterization and cardiovascular interventions |
container_volume | 99 |
creator | Rottländer, Dennis Beucher, Harald Ghaddioui, Karim Al Boekstegers, Peter |
description | Transcatheter edge‐to‐edge repair (TEER) has emerged to address severe mitral and tricuspid valve regurgitation in patients who are at high perioperative risk for open‐heart surgery. No clinical data is available for continuous left and right atrial pressure monitoring using the steerable guiding catheter (SGC) during TEER. In a prospective single‐center study, 40 patients with severe mitral (n = 20) or tricuspid (n = 20) regurgitation underwent TEER with the registration of atrial pressure via the SGC. All patients had successful TEER using the PASCAL Ace repair system, while atrial pressure was monitored continuously via the SGC. Simultaneous right or left atrial pressure monitoring via the SGC and a pigtail catheter during mitral and tricuspid TEER showed excellent reliability for SGC pressure registration. While for mitral TEER the beneficial effects of continuous atrial pressure monitoring are well known, we further evaluated the outcome of patients with tricuspid TEER. Echocardiographic and clinical results after tricuspid TEER showed a reduction of quantitative echocardiographic tricuspid regurgitation parameters and improved New York Heart Association classification after 3‐month follow‐up. Also, qualitative tricuspid valve assessment showed improved tricuspid regurgitation classification postimplantation and at 3‐month follow‐up. Furthermore, right atrial pressure was reduced by 37.6% and mean right atrial pressure by 30.6% after successful tricuspid TEER using the PASCAL Ace device. Continuous atrial pressure monitoring using the SGC of the PASCAL Ace repair system is reliable during mitral and tricuspid TEER. Furthermore, successful tricuspid TEER leads to reduced right atrial pressure. |
doi_str_mv | 10.1002/ccd.30109 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2626003705</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2626003705</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3889-612d51266187bb0791ff2900d97f3f4ea6529f96076c216230fc4f3601defd53</originalsourceid><addsrcrecordid>eNp1kc9O3DAQxq0KVCjtgRdAlriUw8LYTpz1EaWlrYTEhQO3yGuPF6PECbbTihuP0Gfsk9TLLhwq9TJ_f_o0o4-QYwbnDIBfGGPPBTBQ78ghqzlfNFze7e1qpip5QD6k9AAASnL1nhyImrEK6vqQPLdjyD7M45yoztHrnk4RU5oj0mEMPo_RhzX96TVNGTHqVY90PXuL1Oh8jxkj9YHmqEN6Gwy-9D3VwZaFN3OavKVo1_jn-XceS9jUNOKkffxI9p3uE37a5SNye_X1tv2-uL759qO9vF4YsVyqhWTc1oxLyZbNagWNYs5xBWBV44SrUMuaK6ckNNJwJrkAZyonJDCLztbiiHzeyk5xfJwx5W7wyWDf64Dl945LLgFEAxv09B_0YZxjKMcVSlZcMK6WhTrbUiaOKUV03RT9oONTx6DbuNIVV7oXVwp7slOcVwPaN_LVhgJcbIFfvsen_yt1bftlK_kX_RuZKw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2664231298</pqid></control><display><type>article</type><title>Continuous atrial pressure monitoring via steerable guide catheter in transcatheter mitral and tricuspid edge‐to‐edge repair</title><source>Wiley-Blackwell Read & Publish Collection</source><creator>Rottländer, Dennis ; Beucher, Harald ; Ghaddioui, Karim Al ; Boekstegers, Peter</creator><creatorcontrib>Rottländer, Dennis ; Beucher, Harald ; Ghaddioui, Karim Al ; Boekstegers, Peter</creatorcontrib><description>Transcatheter edge‐to‐edge repair (TEER) has emerged to address severe mitral and tricuspid valve regurgitation in patients who are at high perioperative risk for open‐heart surgery. No clinical data is available for continuous left and right atrial pressure monitoring using the steerable guiding catheter (SGC) during TEER. In a prospective single‐center study, 40 patients with severe mitral (n = 20) or tricuspid (n = 20) regurgitation underwent TEER with the registration of atrial pressure via the SGC. All patients had successful TEER using the PASCAL Ace repair system, while atrial pressure was monitored continuously via the SGC. Simultaneous right or left atrial pressure monitoring via the SGC and a pigtail catheter during mitral and tricuspid TEER showed excellent reliability for SGC pressure registration. While for mitral TEER the beneficial effects of continuous atrial pressure monitoring are well known, we further evaluated the outcome of patients with tricuspid TEER. Echocardiographic and clinical results after tricuspid TEER showed a reduction of quantitative echocardiographic tricuspid regurgitation parameters and improved New York Heart Association classification after 3‐month follow‐up. Also, qualitative tricuspid valve assessment showed improved tricuspid regurgitation classification postimplantation and at 3‐month follow‐up. Furthermore, right atrial pressure was reduced by 37.6% and mean right atrial pressure by 30.6% after successful tricuspid TEER using the PASCAL Ace device. Continuous atrial pressure monitoring using the SGC of the PASCAL Ace repair system is reliable during mitral and tricuspid TEER. Furthermore, successful tricuspid TEER leads to reduced right atrial pressure.</description><identifier>ISSN: 1522-1946</identifier><identifier>EISSN: 1522-726X</identifier><identifier>DOI: 10.1002/ccd.30109</identifier><identifier>PMID: 35114055</identifier><language>eng</language><publisher>United States: Wiley Subscription Services, Inc</publisher><subject>Catheters ; Classification ; Heart surgery ; left atrial pressure ; Patients ; Pressure ; Regurgitation ; right atrial pressure ; transcatheter tricuspid valve repair ; Tricuspid valve</subject><ispartof>Catheterization and cardiovascular interventions, 2022-05, Vol.99 (6), p.1796-1806</ispartof><rights>2022 The Authors. published by Wiley Periodicals LLC</rights><rights>2022 The Authors. Catheterization and Cardiovascular Interventions published by Wiley Periodicals LLC.</rights><rights>2022. This article is published under http://creativecommons.org/licenses/by-nc/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3889-612d51266187bb0791ff2900d97f3f4ea6529f96076c216230fc4f3601defd53</citedby><cites>FETCH-LOGICAL-c3889-612d51266187bb0791ff2900d97f3f4ea6529f96076c216230fc4f3601defd53</cites><orcidid>0000-0002-8789-9092</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/35114055$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Rottländer, Dennis</creatorcontrib><creatorcontrib>Beucher, Harald</creatorcontrib><creatorcontrib>Ghaddioui, Karim Al</creatorcontrib><creatorcontrib>Boekstegers, Peter</creatorcontrib><title>Continuous atrial pressure monitoring via steerable guide catheter in transcatheter mitral and tricuspid edge‐to‐edge repair</title><title>Catheterization and cardiovascular interventions</title><addtitle>Catheter Cardiovasc Interv</addtitle><description>Transcatheter edge‐to‐edge repair (TEER) has emerged to address severe mitral and tricuspid valve regurgitation in patients who are at high perioperative risk for open‐heart surgery. No clinical data is available for continuous left and right atrial pressure monitoring using the steerable guiding catheter (SGC) during TEER. In a prospective single‐center study, 40 patients with severe mitral (n = 20) or tricuspid (n = 20) regurgitation underwent TEER with the registration of atrial pressure via the SGC. All patients had successful TEER using the PASCAL Ace repair system, while atrial pressure was monitored continuously via the SGC. Simultaneous right or left atrial pressure monitoring via the SGC and a pigtail catheter during mitral and tricuspid TEER showed excellent reliability for SGC pressure registration. While for mitral TEER the beneficial effects of continuous atrial pressure monitoring are well known, we further evaluated the outcome of patients with tricuspid TEER. Echocardiographic and clinical results after tricuspid TEER showed a reduction of quantitative echocardiographic tricuspid regurgitation parameters and improved New York Heart Association classification after 3‐month follow‐up. Also, qualitative tricuspid valve assessment showed improved tricuspid regurgitation classification postimplantation and at 3‐month follow‐up. Furthermore, right atrial pressure was reduced by 37.6% and mean right atrial pressure by 30.6% after successful tricuspid TEER using the PASCAL Ace device. Continuous atrial pressure monitoring using the SGC of the PASCAL Ace repair system is reliable during mitral and tricuspid TEER. Furthermore, successful tricuspid TEER leads to reduced right atrial pressure.</description><subject>Catheters</subject><subject>Classification</subject><subject>Heart surgery</subject><subject>left atrial pressure</subject><subject>Patients</subject><subject>Pressure</subject><subject>Regurgitation</subject><subject>right atrial pressure</subject><subject>transcatheter tricuspid valve repair</subject><subject>Tricuspid valve</subject><issn>1522-1946</issn><issn>1522-726X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><sourceid>24P</sourceid><recordid>eNp1kc9O3DAQxq0KVCjtgRdAlriUw8LYTpz1EaWlrYTEhQO3yGuPF6PECbbTihuP0Gfsk9TLLhwq9TJ_f_o0o4-QYwbnDIBfGGPPBTBQ78ghqzlfNFze7e1qpip5QD6k9AAASnL1nhyImrEK6vqQPLdjyD7M45yoztHrnk4RU5oj0mEMPo_RhzX96TVNGTHqVY90PXuL1Oh8jxkj9YHmqEN6Gwy-9D3VwZaFN3OavKVo1_jn-XceS9jUNOKkffxI9p3uE37a5SNye_X1tv2-uL759qO9vF4YsVyqhWTc1oxLyZbNagWNYs5xBWBV44SrUMuaK6ckNNJwJrkAZyonJDCLztbiiHzeyk5xfJwx5W7wyWDf64Dl945LLgFEAxv09B_0YZxjKMcVSlZcMK6WhTrbUiaOKUV03RT9oONTx6DbuNIVV7oXVwp7slOcVwPaN_LVhgJcbIFfvsen_yt1bftlK_kX_RuZKw</recordid><startdate>20220501</startdate><enddate>20220501</enddate><creator>Rottländer, Dennis</creator><creator>Beucher, Harald</creator><creator>Ghaddioui, Karim Al</creator><creator>Boekstegers, Peter</creator><general>Wiley Subscription Services, Inc</general><scope>24P</scope><scope>WIN</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7T5</scope><scope>7U9</scope><scope>H94</scope><scope>K9.</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-8789-9092</orcidid></search><sort><creationdate>20220501</creationdate><title>Continuous atrial pressure monitoring via steerable guide catheter in transcatheter mitral and tricuspid edge‐to‐edge repair</title><author>Rottländer, Dennis ; Beucher, Harald ; Ghaddioui, Karim Al ; Boekstegers, Peter</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3889-612d51266187bb0791ff2900d97f3f4ea6529f96076c216230fc4f3601defd53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Catheters</topic><topic>Classification</topic><topic>Heart surgery</topic><topic>left atrial pressure</topic><topic>Patients</topic><topic>Pressure</topic><topic>Regurgitation</topic><topic>right atrial pressure</topic><topic>transcatheter tricuspid valve repair</topic><topic>Tricuspid valve</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Rottländer, Dennis</creatorcontrib><creatorcontrib>Beucher, Harald</creatorcontrib><creatorcontrib>Ghaddioui, Karim Al</creatorcontrib><creatorcontrib>Boekstegers, Peter</creatorcontrib><collection>Wiley Open Access</collection><collection>Wiley Online Library Journals</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Immunology Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>MEDLINE - Academic</collection><jtitle>Catheterization and cardiovascular interventions</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Rottländer, Dennis</au><au>Beucher, Harald</au><au>Ghaddioui, Karim Al</au><au>Boekstegers, Peter</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Continuous atrial pressure monitoring via steerable guide catheter in transcatheter mitral and tricuspid edge‐to‐edge repair</atitle><jtitle>Catheterization and cardiovascular interventions</jtitle><addtitle>Catheter Cardiovasc Interv</addtitle><date>2022-05-01</date><risdate>2022</risdate><volume>99</volume><issue>6</issue><spage>1796</spage><epage>1806</epage><pages>1796-1806</pages><issn>1522-1946</issn><eissn>1522-726X</eissn><abstract>Transcatheter edge‐to‐edge repair (TEER) has emerged to address severe mitral and tricuspid valve regurgitation in patients who are at high perioperative risk for open‐heart surgery. No clinical data is available for continuous left and right atrial pressure monitoring using the steerable guiding catheter (SGC) during TEER. In a prospective single‐center study, 40 patients with severe mitral (n = 20) or tricuspid (n = 20) regurgitation underwent TEER with the registration of atrial pressure via the SGC. All patients had successful TEER using the PASCAL Ace repair system, while atrial pressure was monitored continuously via the SGC. Simultaneous right or left atrial pressure monitoring via the SGC and a pigtail catheter during mitral and tricuspid TEER showed excellent reliability for SGC pressure registration. While for mitral TEER the beneficial effects of continuous atrial pressure monitoring are well known, we further evaluated the outcome of patients with tricuspid TEER. Echocardiographic and clinical results after tricuspid TEER showed a reduction of quantitative echocardiographic tricuspid regurgitation parameters and improved New York Heart Association classification after 3‐month follow‐up. Also, qualitative tricuspid valve assessment showed improved tricuspid regurgitation classification postimplantation and at 3‐month follow‐up. Furthermore, right atrial pressure was reduced by 37.6% and mean right atrial pressure by 30.6% after successful tricuspid TEER using the PASCAL Ace device. Continuous atrial pressure monitoring using the SGC of the PASCAL Ace repair system is reliable during mitral and tricuspid TEER. Furthermore, successful tricuspid TEER leads to reduced right atrial pressure.</abstract><cop>United States</cop><pub>Wiley Subscription Services, Inc</pub><pmid>35114055</pmid><doi>10.1002/ccd.30109</doi><tpages>11</tpages><orcidid>https://orcid.org/0000-0002-8789-9092</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1522-1946 |
ispartof | Catheterization and cardiovascular interventions, 2022-05, Vol.99 (6), p.1796-1806 |
issn | 1522-1946 1522-726X |
language | eng |
recordid | cdi_proquest_miscellaneous_2626003705 |
source | Wiley-Blackwell Read & Publish Collection |
subjects | Catheters Classification Heart surgery left atrial pressure Patients Pressure Regurgitation right atrial pressure transcatheter tricuspid valve repair Tricuspid valve |
title | Continuous atrial pressure monitoring via steerable guide catheter in transcatheter mitral and tricuspid edge‐to‐edge repair |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T22%3A35%3A41IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Continuous%20atrial%20pressure%20monitoring%20via%20steerable%20guide%20catheter%20in%20transcatheter%20mitral%20and%20tricuspid%20edge%E2%80%90to%E2%80%90edge%20repair&rft.jtitle=Catheterization%20and%20cardiovascular%20interventions&rft.au=Rottl%C3%A4nder,%20Dennis&rft.date=2022-05-01&rft.volume=99&rft.issue=6&rft.spage=1796&rft.epage=1806&rft.pages=1796-1806&rft.issn=1522-1946&rft.eissn=1522-726X&rft_id=info:doi/10.1002/ccd.30109&rft_dat=%3Cproquest_cross%3E2626003705%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c3889-612d51266187bb0791ff2900d97f3f4ea6529f96076c216230fc4f3601defd53%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2664231298&rft_id=info:pmid/35114055&rfr_iscdi=true |