Radiation tests of ITER diagnostic system materials in the BOR-60 reactor
An in-pile experiment was conducted up to a fluence of 9.9 × 10 25 m 2 ( E ≫ 0.1 MeV) which investigated the following electrophysical characteristics of a cable with mineral insulation and nickel conductor: insulation resistance, radiation-induced current and EMF. Irradiation was also performed in...
Saved in:
Published in: | Journal of nuclear materials 1996-10, Vol.233 (1-3), p.1229-1232 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | An in-pile experiment was conducted up to a fluence of 9.9 × 10
25 m
2 (
E ≫ 0.1 MeV) which investigated the following electrophysical characteristics of a cable with mineral insulation and nickel conductor: insulation resistance, radiation-induced current and EMF. Irradiation was also performed in the BOR-60 reactor up to a fluence 10
23 m
−2 on six crystal types for the monochromator: mica, LiF, multilayered mirrors Fe/C, W/Si, Cr/C and Mo/Si. Change of the reflectivity, width and shape of diffraction reflections were investigated. |
---|---|