Experience with the application of thermal analysis in high-voltage insulation investigations

The possibilities of application of DTA and TG are illustrated in an investigation of the changes in quality of high-voltage insulation, one of which is an organic filler-modified epoxy resin gum. Thermal analysis can be used to assess the degree of degradation, as presented on the examples of Relan...

Full description

Saved in:
Bibliographic Details
Published in:Journal of thermal analysis 1993-10, Vol.39 (10), p.1355-1366
Main Author: MENTLIK, V
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 1366
container_issue 10
container_start_page 1355
container_title Journal of thermal analysis
container_volume 39
creator MENTLIK, V
description The possibilities of application of DTA and TG are illustrated in an investigation of the changes in quality of high-voltage insulation, one of which is an organic filler-modified epoxy resin gum. Thermal analysis can be used to assess the degree of degradation, as presented on the examples of Relanex and Sklotextit stressed by temperature, and also to observe the course of hardening of materials and hence to follow the technology in the course of production. The possibility of use of this method is shown for electric rotating machines without damage to their insulation system. The possibility of the use of DTA and TG is presented for determination of the slope of the straight line plot of the lifetime of an insulation.
format article
fullrecord <record><control><sourceid>proquest_pasca</sourceid><recordid>TN_cdi_proquest_miscellaneous_26345283</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>26345283</sourcerecordid><originalsourceid>FETCH-LOGICAL-p603-9e815571c76bd0a4661d3d50a45246e26d2998c3d41b5aa596e9204ba124c7c73</originalsourceid><addsrcrecordid>eNotjstOwzAURL0AiVL4By8Qu0hO_Ii9RFV5SJXYdIuiG8dJjBzH2Gmhf4-hXc2d0dHcuUIrQoUsGBPiBt2m9EkIZ0TVK_Sx_QkmWuO1wd92GfEyGgwhOKthsbPHc_8XxQkcBg_ulGzC1uPRDmNxnN0Cg8k-HdwZt_5o0mKHf5fu0HUPLpn7i67R_nm737wWu_eXt83TrgiC0EIZWXJel7oWbUcgjyw72vF88YoJU4muUkpq2rGy5QBcCaMqwlooK6ZrXdM1ejzXhjh_HfL_ZrJJG-fAm_mQmkrQXCVpBh8uICQNro_gtU1NiHaCeGqopFKUgv4CerFdPg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>26345283</pqid></control><display><type>article</type><title>Experience with the application of thermal analysis in high-voltage insulation investigations</title><source>Springer Nature - Connect here FIRST to enable access</source><creator>MENTLIK, V</creator><creatorcontrib>MENTLIK, V</creatorcontrib><description>The possibilities of application of DTA and TG are illustrated in an investigation of the changes in quality of high-voltage insulation, one of which is an organic filler-modified epoxy resin gum. Thermal analysis can be used to assess the degree of degradation, as presented on the examples of Relanex and Sklotextit stressed by temperature, and also to observe the course of hardening of materials and hence to follow the technology in the course of production. The possibility of use of this method is shown for electric rotating machines without damage to their insulation system. The possibility of the use of DTA and TG is presented for determination of the slope of the straight line plot of the lifetime of an insulation.</description><identifier>ISSN: 0368-4466</identifier><identifier>CODEN: JTHEA9</identifier><language>eng</language><publisher>Budapest: Akadémiai Kiadó</publisher><subject>Applied sciences ; Electrical engineering. Electrical power engineering ; Exact sciences and technology ; Materials</subject><ispartof>Journal of thermal analysis, 1993-10, Vol.39 (10), p.1355-1366</ispartof><rights>1994 INIST-CNRS</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=3838616$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>MENTLIK, V</creatorcontrib><title>Experience with the application of thermal analysis in high-voltage insulation investigations</title><title>Journal of thermal analysis</title><description>The possibilities of application of DTA and TG are illustrated in an investigation of the changes in quality of high-voltage insulation, one of which is an organic filler-modified epoxy resin gum. Thermal analysis can be used to assess the degree of degradation, as presented on the examples of Relanex and Sklotextit stressed by temperature, and also to observe the course of hardening of materials and hence to follow the technology in the course of production. The possibility of use of this method is shown for electric rotating machines without damage to their insulation system. The possibility of the use of DTA and TG is presented for determination of the slope of the straight line plot of the lifetime of an insulation.</description><subject>Applied sciences</subject><subject>Electrical engineering. Electrical power engineering</subject><subject>Exact sciences and technology</subject><subject>Materials</subject><issn>0368-4466</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1993</creationdate><recordtype>article</recordtype><recordid>eNotjstOwzAURL0AiVL4By8Qu0hO_Ii9RFV5SJXYdIuiG8dJjBzH2Gmhf4-hXc2d0dHcuUIrQoUsGBPiBt2m9EkIZ0TVK_Sx_QkmWuO1wd92GfEyGgwhOKthsbPHc_8XxQkcBg_ulGzC1uPRDmNxnN0Cg8k-HdwZt_5o0mKHf5fu0HUPLpn7i67R_nm737wWu_eXt83TrgiC0EIZWXJel7oWbUcgjyw72vF88YoJU4muUkpq2rGy5QBcCaMqwlooK6ZrXdM1ejzXhjh_HfL_ZrJJG-fAm_mQmkrQXCVpBh8uICQNro_gtU1NiHaCeGqopFKUgv4CerFdPg</recordid><startdate>19931001</startdate><enddate>19931001</enddate><creator>MENTLIK, V</creator><general>Akadémiai Kiadó</general><general>Wiley</general><scope>IQODW</scope><scope>7SR</scope><scope>8FD</scope><scope>JG9</scope></search><sort><creationdate>19931001</creationdate><title>Experience with the application of thermal analysis in high-voltage insulation investigations</title><author>MENTLIK, V</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p603-9e815571c76bd0a4661d3d50a45246e26d2998c3d41b5aa596e9204ba124c7c73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1993</creationdate><topic>Applied sciences</topic><topic>Electrical engineering. Electrical power engineering</topic><topic>Exact sciences and technology</topic><topic>Materials</topic><toplevel>online_resources</toplevel><creatorcontrib>MENTLIK, V</creatorcontrib><collection>Pascal-Francis</collection><collection>Engineered Materials Abstracts</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><jtitle>Journal of thermal analysis</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>MENTLIK, V</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Experience with the application of thermal analysis in high-voltage insulation investigations</atitle><jtitle>Journal of thermal analysis</jtitle><date>1993-10-01</date><risdate>1993</risdate><volume>39</volume><issue>10</issue><spage>1355</spage><epage>1366</epage><pages>1355-1366</pages><issn>0368-4466</issn><coden>JTHEA9</coden><abstract>The possibilities of application of DTA and TG are illustrated in an investigation of the changes in quality of high-voltage insulation, one of which is an organic filler-modified epoxy resin gum. Thermal analysis can be used to assess the degree of degradation, as presented on the examples of Relanex and Sklotextit stressed by temperature, and also to observe the course of hardening of materials and hence to follow the technology in the course of production. The possibility of use of this method is shown for electric rotating machines without damage to their insulation system. The possibility of the use of DTA and TG is presented for determination of the slope of the straight line plot of the lifetime of an insulation.</abstract><cop>Budapest</cop><cop>Chichester</cop><pub>Akadémiai Kiadó</pub><tpages>12</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0368-4466
ispartof Journal of thermal analysis, 1993-10, Vol.39 (10), p.1355-1366
issn 0368-4466
language eng
recordid cdi_proquest_miscellaneous_26345283
source Springer Nature - Connect here FIRST to enable access
subjects Applied sciences
Electrical engineering. Electrical power engineering
Exact sciences and technology
Materials
title Experience with the application of thermal analysis in high-voltage insulation investigations
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T17%3A06%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pasca&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Experience%20with%20the%20application%20of%20thermal%20analysis%20in%20high-voltage%20insulation%20investigations&rft.jtitle=Journal%20of%20thermal%20analysis&rft.au=MENTLIK,%20V&rft.date=1993-10-01&rft.volume=39&rft.issue=10&rft.spage=1355&rft.epage=1366&rft.pages=1355-1366&rft.issn=0368-4466&rft.coden=JTHEA9&rft_id=info:doi/&rft_dat=%3Cproquest_pasca%3E26345283%3C/proquest_pasca%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-p603-9e815571c76bd0a4661d3d50a45246e26d2998c3d41b5aa596e9204ba124c7c73%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=26345283&rft_id=info:pmid/&rfr_iscdi=true