Determination of tungsten in low-grade tungsten ores by dual-column ion chromatography

A simple and rapid method was developed for the determination of tungsten in low-grade tungsten ores by dual-column ion chromatography using a conductivity detector. The chromatographic parameters based on ion selectivity, retention time and signal response were optimized for tungstate ion. Chloride...

Full description

Saved in:
Bibliographic Details
Published in:Analytica chimica acta 1994-03, Vol.287 (3), p.229-234
Main Authors: Wagh, D.N., Kumar, Sangita D., Iyer, C.S.P.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c364t-aa2ecb4aac04127115a64d1e2bc97d287a6279252e7c92dd748a9c5866f8c053
cites cdi_FETCH-LOGICAL-c364t-aa2ecb4aac04127115a64d1e2bc97d287a6279252e7c92dd748a9c5866f8c053
container_end_page 234
container_issue 3
container_start_page 229
container_title Analytica chimica acta
container_volume 287
creator Wagh, D.N.
Kumar, Sangita D.
Iyer, C.S.P.
description A simple and rapid method was developed for the determination of tungsten in low-grade tungsten ores by dual-column ion chromatography using a conductivity detector. The chromatographic parameters based on ion selectivity, retention time and signal response were optimized for tungstate ion. Chloride, fluoride, sulphate, nitrate, chromate, molybdate and vanadate anions did not interfere in the determination. The reliability of the methods was tested by analysing two CANMET (Canadian reference) standards. The detection limit for tungstate was 1.35 mg 1 −1. The relative standard deviation ( n = 10) for the sample was 4.3% WO 3. The method was validated by analysing the ore samples by spectrophotometry using thiocyanate, neutron activation analysis and energy-dispersive x-ray fluorescence spectrometry.
doi_str_mv 10.1016/0003-2670(93)E0599-3
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_26359613</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>0003267093E05993</els_id><sourcerecordid>26359613</sourcerecordid><originalsourceid>FETCH-LOGICAL-c364t-aa2ecb4aac04127115a64d1e2bc97d287a6279252e7c92dd748a9c5866f8c053</originalsourceid><addsrcrecordid>eNp9kE1LxDAQhoMouK7-Aw89iOihmq8mzUUQXT9A8CJew2w6dSNtsyatsv_erivrzdMww_POMA8hx4xeMMrUJaVU5FxpembE-YwWxuRih0xYqUUuBZe7ZLJF9slBSu9jyxmVE_J6iz3G1nfQ-9Bloc76oXtLPXaZ77ImfOVvESr8m4aIKZuvsmqAJnehGdqRHJNuEUMLfRjx5WJ1SPZqaBIe_dYpebmbvdw85E_P948310-5E0r2OQBHN5cAjkrGNWMFKFkx5HNndMVLDYprwwuO2hleVVqWYFxRKlWXjhZiSk43a5cxfAyYetv65LBpoMMwJMuVKIxiYgTlBnQxpBSxtsvoW4gry6hdO7RrQXYtyBphfxzadezkdz8kB00doXM-bbPCFJpxOmJXGwzHVz89Rpucx85h5SO63lbB_3_nGykEhfs</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>26359613</pqid></control><display><type>article</type><title>Determination of tungsten in low-grade tungsten ores by dual-column ion chromatography</title><source>ScienceDirect Physical &amp; Analytical Chemistry Backfile</source><creator>Wagh, D.N. ; Kumar, Sangita D. ; Iyer, C.S.P.</creator><creatorcontrib>Wagh, D.N. ; Kumar, Sangita D. ; Iyer, C.S.P.</creatorcontrib><description>A simple and rapid method was developed for the determination of tungsten in low-grade tungsten ores by dual-column ion chromatography using a conductivity detector. The chromatographic parameters based on ion selectivity, retention time and signal response were optimized for tungstate ion. Chloride, fluoride, sulphate, nitrate, chromate, molybdate and vanadate anions did not interfere in the determination. The reliability of the methods was tested by analysing two CANMET (Canadian reference) standards. The detection limit for tungstate was 1.35 mg 1 −1. The relative standard deviation ( n = 10) for the sample was 4.3% WO 3. The method was validated by analysing the ore samples by spectrophotometry using thiocyanate, neutron activation analysis and energy-dispersive x-ray fluorescence spectrometry.</description><identifier>ISSN: 0003-2670</identifier><identifier>EISSN: 1873-4324</identifier><identifier>DOI: 10.1016/0003-2670(93)E0599-3</identifier><identifier>CODEN: ACACAM</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Analytical chemistry ; Chemistry ; Chromatographic methods and physical methods associated with chromatography ; Exact sciences and technology ; Ion chromatography ; Ores ; Other chromatographic methods ; Tungsten</subject><ispartof>Analytica chimica acta, 1994-03, Vol.287 (3), p.229-234</ispartof><rights>1994</rights><rights>1994 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c364t-aa2ecb4aac04127115a64d1e2bc97d287a6279252e7c92dd748a9c5866f8c053</citedby><cites>FETCH-LOGICAL-c364t-aa2ecb4aac04127115a64d1e2bc97d287a6279252e7c92dd748a9c5866f8c053</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/0003267093E05993$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3619,27924,27925,45983</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=3957120$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Wagh, D.N.</creatorcontrib><creatorcontrib>Kumar, Sangita D.</creatorcontrib><creatorcontrib>Iyer, C.S.P.</creatorcontrib><title>Determination of tungsten in low-grade tungsten ores by dual-column ion chromatography</title><title>Analytica chimica acta</title><description>A simple and rapid method was developed for the determination of tungsten in low-grade tungsten ores by dual-column ion chromatography using a conductivity detector. The chromatographic parameters based on ion selectivity, retention time and signal response were optimized for tungstate ion. Chloride, fluoride, sulphate, nitrate, chromate, molybdate and vanadate anions did not interfere in the determination. The reliability of the methods was tested by analysing two CANMET (Canadian reference) standards. The detection limit for tungstate was 1.35 mg 1 −1. The relative standard deviation ( n = 10) for the sample was 4.3% WO 3. The method was validated by analysing the ore samples by spectrophotometry using thiocyanate, neutron activation analysis and energy-dispersive x-ray fluorescence spectrometry.</description><subject>Analytical chemistry</subject><subject>Chemistry</subject><subject>Chromatographic methods and physical methods associated with chromatography</subject><subject>Exact sciences and technology</subject><subject>Ion chromatography</subject><subject>Ores</subject><subject>Other chromatographic methods</subject><subject>Tungsten</subject><issn>0003-2670</issn><issn>1873-4324</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1994</creationdate><recordtype>article</recordtype><recordid>eNp9kE1LxDAQhoMouK7-Aw89iOihmq8mzUUQXT9A8CJew2w6dSNtsyatsv_erivrzdMww_POMA8hx4xeMMrUJaVU5FxpembE-YwWxuRih0xYqUUuBZe7ZLJF9slBSu9jyxmVE_J6iz3G1nfQ-9Bloc76oXtLPXaZ77ImfOVvESr8m4aIKZuvsmqAJnehGdqRHJNuEUMLfRjx5WJ1SPZqaBIe_dYpebmbvdw85E_P948310-5E0r2OQBHN5cAjkrGNWMFKFkx5HNndMVLDYprwwuO2hleVVqWYFxRKlWXjhZiSk43a5cxfAyYetv65LBpoMMwJMuVKIxiYgTlBnQxpBSxtsvoW4gry6hdO7RrQXYtyBphfxzadezkdz8kB00doXM-bbPCFJpxOmJXGwzHVz89Rpucx85h5SO63lbB_3_nGykEhfs</recordid><startdate>19940321</startdate><enddate>19940321</enddate><creator>Wagh, D.N.</creator><creator>Kumar, Sangita D.</creator><creator>Iyer, C.S.P.</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope></search><sort><creationdate>19940321</creationdate><title>Determination of tungsten in low-grade tungsten ores by dual-column ion chromatography</title><author>Wagh, D.N. ; Kumar, Sangita D. ; Iyer, C.S.P.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c364t-aa2ecb4aac04127115a64d1e2bc97d287a6279252e7c92dd748a9c5866f8c053</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1994</creationdate><topic>Analytical chemistry</topic><topic>Chemistry</topic><topic>Chromatographic methods and physical methods associated with chromatography</topic><topic>Exact sciences and technology</topic><topic>Ion chromatography</topic><topic>Ores</topic><topic>Other chromatographic methods</topic><topic>Tungsten</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wagh, D.N.</creatorcontrib><creatorcontrib>Kumar, Sangita D.</creatorcontrib><creatorcontrib>Iyer, C.S.P.</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><jtitle>Analytica chimica acta</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wagh, D.N.</au><au>Kumar, Sangita D.</au><au>Iyer, C.S.P.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Determination of tungsten in low-grade tungsten ores by dual-column ion chromatography</atitle><jtitle>Analytica chimica acta</jtitle><date>1994-03-21</date><risdate>1994</risdate><volume>287</volume><issue>3</issue><spage>229</spage><epage>234</epage><pages>229-234</pages><issn>0003-2670</issn><eissn>1873-4324</eissn><coden>ACACAM</coden><abstract>A simple and rapid method was developed for the determination of tungsten in low-grade tungsten ores by dual-column ion chromatography using a conductivity detector. The chromatographic parameters based on ion selectivity, retention time and signal response were optimized for tungstate ion. Chloride, fluoride, sulphate, nitrate, chromate, molybdate and vanadate anions did not interfere in the determination. The reliability of the methods was tested by analysing two CANMET (Canadian reference) standards. The detection limit for tungstate was 1.35 mg 1 −1. The relative standard deviation ( n = 10) for the sample was 4.3% WO 3. The method was validated by analysing the ore samples by spectrophotometry using thiocyanate, neutron activation analysis and energy-dispersive x-ray fluorescence spectrometry.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><doi>10.1016/0003-2670(93)E0599-3</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-2670
ispartof Analytica chimica acta, 1994-03, Vol.287 (3), p.229-234
issn 0003-2670
1873-4324
language eng
recordid cdi_proquest_miscellaneous_26359613
source ScienceDirect Physical & Analytical Chemistry Backfile
subjects Analytical chemistry
Chemistry
Chromatographic methods and physical methods associated with chromatography
Exact sciences and technology
Ion chromatography
Ores
Other chromatographic methods
Tungsten
title Determination of tungsten in low-grade tungsten ores by dual-column ion chromatography
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T20%3A05%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Determination%20of%20tungsten%20in%20low-grade%20tungsten%20ores%20by%20dual-column%20ion%20chromatography&rft.jtitle=Analytica%20chimica%20acta&rft.au=Wagh,%20D.N.&rft.date=1994-03-21&rft.volume=287&rft.issue=3&rft.spage=229&rft.epage=234&rft.pages=229-234&rft.issn=0003-2670&rft.eissn=1873-4324&rft.coden=ACACAM&rft_id=info:doi/10.1016/0003-2670(93)E0599-3&rft_dat=%3Cproquest_cross%3E26359613%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c364t-aa2ecb4aac04127115a64d1e2bc97d287a6279252e7c92dd748a9c5866f8c053%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=26359613&rft_id=info:pmid/&rfr_iscdi=true