Loading…
Efficacy of two polishing systems in reestablishing the surface smoothness of posterior monolithic lithium disilicate restorations: One-year results of a split-mouth randomized controlled clinical trial
Selecting the optimal polishing procedure to reestablish surface smoothness after occlusal adjustment is essential for the long-term success of glass-ceramic restorations. While in vitro studies have shown different effective polishing protocols, clinical trials are lacking. The purpose of this spli...
Saved in:
Published in: | The Journal of prosthetic dentistry 2024-01, Vol.131 (1), p.25-33 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | cdi_FETCH-LOGICAL-c315t-b01370740d2505bea274e493cfe37a7cc9db8efa3a27522cb7f8f4a4a36f91733 |
container_end_page | 33 |
container_issue | 1 |
container_start_page | 25 |
container_title | The Journal of prosthetic dentistry |
container_volume | 131 |
creator | Caixeta, Mariana Tassinari de Oliveira, Danila Isquierdo de Souza, Fernando Rocha, Eduardo Passos |
description | Selecting the optimal polishing procedure to reestablish surface smoothness after occlusal adjustment is essential for the long-term success of glass-ceramic restorations. While in vitro studies have shown different effective polishing protocols, clinical trials are lacking.
The purpose of this split-mouth controlled clinical trial was to evaluate the effectiveness of 2 polishing systems in reestablishing the surface smoothness of posterior monolithic lithium disilicate ceramic restorations.
Ninety-six restorations that required occlusal adjustment after bonding were randomized into 2 groups: Forty-eight restorations were polished by using the Exa Cerapol polishing kit, and the other 48 restorations were polished by using the Shofu polishing kit. The restorations were replicated with epoxy resin at 3 study times—after bonding (t1), after occlusal adjustment (t2), and after polishing (t3)—for quantitative roughness analysis (Ra). Representative specimens from each group were qualitatively analyzed by using a confocal laser microscope. Clinical analyses were performed after the polishing procedure and at 30, 180, and 365 days after the polishing procedure by following the United States Public Health Service (USPHS) criteria. ANOVA and the Tukey multiple comparisons parametric tests were computed (α=.05). The Kaplan-Meier test was used to analyze the survival rate of restorations.
No statistically significant difference was found between the Exa Cerapol and Shofu groups (P=.086). A statistically significant difference was found between study times t1 and t2 and between t2 and t3 (both P |
doi_str_mv | 10.1016/j.prosdent.2022.01.008 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2638728146</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0022391322000518</els_id><sourcerecordid>2638728146</sourcerecordid><originalsourceid>FETCH-LOGICAL-c315t-b01370740d2505bea274e493cfe37a7cc9db8efa3a27522cb7f8f4a4a36f91733</originalsourceid><addsrcrecordid>eNqFkc1u1TAQhS0EoreFV6i8ZJPUP0mcsAJV5Ueq1A2sLccZE1859sV2QLePyFPh9PayZTWW55wzmvkQuqakpoR2N_v6EEOawOeaEcZqQmtC-hdoR8kgqq5v6Eu0I6VT8YHyC3SZ0p4URSvoa3TBWyZY3_Ad-nNnjNVKH3EwOP8O-BCcTbP1P3A6pgxLwtbjCJCyGs-dPANOazRKl7qEkGcPKW0Jh1A80YaIl-BLUp6txk9lXfBkk3VlWIYSmHKIKtvg03v84KE6gorb9-ryU5LC6VCM1RLWPOOo_BQW-wgT1sHnGJzbns76kudwjla5N-iVUS7B2-d6hb5_uvt2-6W6f_j89fbjfaU5bXM1EsoFEQ2ZWEvaERQTDTQD1wa4UELrYRp7MIqXRsuYHoXpTaMaxTszUMH5FXp3yi0Efq5lEbnYpME55SGsSbKO9-W6tOmKtDtJdYGVIhh5iHZR8SgpkRtHuZdnjnLjKAmVhVIxXj_PWMcFpn-2M7gi-HASQNn0l4Uok7bgNUw2gs5yCvZ_M_4CLN-58w</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2638728146</pqid></control><display><type>article</type><title>Efficacy of two polishing systems in reestablishing the surface smoothness of posterior monolithic lithium disilicate restorations: One-year results of a split-mouth randomized controlled clinical trial</title><source>ScienceDirect Journals</source><creator>Caixeta, Mariana Tassinari ; de Oliveira, Danila ; Isquierdo de Souza, Fernando ; Rocha, Eduardo Passos</creator><creatorcontrib>Caixeta, Mariana Tassinari ; de Oliveira, Danila ; Isquierdo de Souza, Fernando ; Rocha, Eduardo Passos</creatorcontrib><description>Selecting the optimal polishing procedure to reestablish surface smoothness after occlusal adjustment is essential for the long-term success of glass-ceramic restorations. While in vitro studies have shown different effective polishing protocols, clinical trials are lacking.
The purpose of this split-mouth controlled clinical trial was to evaluate the effectiveness of 2 polishing systems in reestablishing the surface smoothness of posterior monolithic lithium disilicate ceramic restorations.
Ninety-six restorations that required occlusal adjustment after bonding were randomized into 2 groups: Forty-eight restorations were polished by using the Exa Cerapol polishing kit, and the other 48 restorations were polished by using the Shofu polishing kit. The restorations were replicated with epoxy resin at 3 study times—after bonding (t1), after occlusal adjustment (t2), and after polishing (t3)—for quantitative roughness analysis (Ra). Representative specimens from each group were qualitatively analyzed by using a confocal laser microscope. Clinical analyses were performed after the polishing procedure and at 30, 180, and 365 days after the polishing procedure by following the United States Public Health Service (USPHS) criteria. ANOVA and the Tukey multiple comparisons parametric tests were computed (α=.05). The Kaplan-Meier test was used to analyze the survival rate of restorations.
No statistically significant difference was found between the Exa Cerapol and Shofu groups (P=.086). A statistically significant difference was found between study times t1 and t2 and between t2 and t3 (both P<.001) in both experimental groups. No statistically significant difference was found between study times t1 and t3 (P=.181) in either experimental group. For the clinical criterion “integrity of restorations,” all the elements analyzed indicated an alfa grade at all study times. The survival rate of the restorations was 100%.
Both polishing kits were effective in reestablishing the surface smoothness of restorations after occlusal adjustment.</description><identifier>ISSN: 0022-3913</identifier><identifier>EISSN: 1097-6841</identifier><identifier>DOI: 10.1016/j.prosdent.2022.01.008</identifier><identifier>PMID: 35272843</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><ispartof>The Journal of prosthetic dentistry, 2024-01, Vol.131 (1), p.25-33</ispartof><rights>2022 Editorial Council for The Journal of Prosthetic Dentistry</rights><rights>Copyright © 2022 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c315t-b01370740d2505bea274e493cfe37a7cc9db8efa3a27522cb7f8f4a4a36f91733</cites><orcidid>0000-0001-7788-0243</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/35272843$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Caixeta, Mariana Tassinari</creatorcontrib><creatorcontrib>de Oliveira, Danila</creatorcontrib><creatorcontrib>Isquierdo de Souza, Fernando</creatorcontrib><creatorcontrib>Rocha, Eduardo Passos</creatorcontrib><title>Efficacy of two polishing systems in reestablishing the surface smoothness of posterior monolithic lithium disilicate restorations: One-year results of a split-mouth randomized controlled clinical trial</title><title>The Journal of prosthetic dentistry</title><addtitle>J Prosthet Dent</addtitle><description>Selecting the optimal polishing procedure to reestablish surface smoothness after occlusal adjustment is essential for the long-term success of glass-ceramic restorations. While in vitro studies have shown different effective polishing protocols, clinical trials are lacking.
The purpose of this split-mouth controlled clinical trial was to evaluate the effectiveness of 2 polishing systems in reestablishing the surface smoothness of posterior monolithic lithium disilicate ceramic restorations.
Ninety-six restorations that required occlusal adjustment after bonding were randomized into 2 groups: Forty-eight restorations were polished by using the Exa Cerapol polishing kit, and the other 48 restorations were polished by using the Shofu polishing kit. The restorations were replicated with epoxy resin at 3 study times—after bonding (t1), after occlusal adjustment (t2), and after polishing (t3)—for quantitative roughness analysis (Ra). Representative specimens from each group were qualitatively analyzed by using a confocal laser microscope. Clinical analyses were performed after the polishing procedure and at 30, 180, and 365 days after the polishing procedure by following the United States Public Health Service (USPHS) criteria. ANOVA and the Tukey multiple comparisons parametric tests were computed (α=.05). The Kaplan-Meier test was used to analyze the survival rate of restorations.
No statistically significant difference was found between the Exa Cerapol and Shofu groups (P=.086). A statistically significant difference was found between study times t1 and t2 and between t2 and t3 (both P<.001) in both experimental groups. No statistically significant difference was found between study times t1 and t3 (P=.181) in either experimental group. For the clinical criterion “integrity of restorations,” all the elements analyzed indicated an alfa grade at all study times. The survival rate of the restorations was 100%.
Both polishing kits were effective in reestablishing the surface smoothness of restorations after occlusal adjustment.</description><issn>0022-3913</issn><issn>1097-6841</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNqFkc1u1TAQhS0EoreFV6i8ZJPUP0mcsAJV5Ueq1A2sLccZE1859sV2QLePyFPh9PayZTWW55wzmvkQuqakpoR2N_v6EEOawOeaEcZqQmtC-hdoR8kgqq5v6Eu0I6VT8YHyC3SZ0p4URSvoa3TBWyZY3_Ad-nNnjNVKH3EwOP8O-BCcTbP1P3A6pgxLwtbjCJCyGs-dPANOazRKl7qEkGcPKW0Jh1A80YaIl-BLUp6txk9lXfBkk3VlWIYSmHKIKtvg03v84KE6gorb9-ryU5LC6VCM1RLWPOOo_BQW-wgT1sHnGJzbns76kudwjla5N-iVUS7B2-d6hb5_uvt2-6W6f_j89fbjfaU5bXM1EsoFEQ2ZWEvaERQTDTQD1wa4UELrYRp7MIqXRsuYHoXpTaMaxTszUMH5FXp3yi0Efq5lEbnYpME55SGsSbKO9-W6tOmKtDtJdYGVIhh5iHZR8SgpkRtHuZdnjnLjKAmVhVIxXj_PWMcFpn-2M7gi-HASQNn0l4Uok7bgNUw2gs5yCvZ_M_4CLN-58w</recordid><startdate>202401</startdate><enddate>202401</enddate><creator>Caixeta, Mariana Tassinari</creator><creator>de Oliveira, Danila</creator><creator>Isquierdo de Souza, Fernando</creator><creator>Rocha, Eduardo Passos</creator><general>Elsevier Inc</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-7788-0243</orcidid></search><sort><creationdate>202401</creationdate><title>Efficacy of two polishing systems in reestablishing the surface smoothness of posterior monolithic lithium disilicate restorations: One-year results of a split-mouth randomized controlled clinical trial</title><author>Caixeta, Mariana Tassinari ; de Oliveira, Danila ; Isquierdo de Souza, Fernando ; Rocha, Eduardo Passos</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c315t-b01370740d2505bea274e493cfe37a7cc9db8efa3a27522cb7f8f4a4a36f91733</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Caixeta, Mariana Tassinari</creatorcontrib><creatorcontrib>de Oliveira, Danila</creatorcontrib><creatorcontrib>Isquierdo de Souza, Fernando</creatorcontrib><creatorcontrib>Rocha, Eduardo Passos</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of prosthetic dentistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Caixeta, Mariana Tassinari</au><au>de Oliveira, Danila</au><au>Isquierdo de Souza, Fernando</au><au>Rocha, Eduardo Passos</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Efficacy of two polishing systems in reestablishing the surface smoothness of posterior monolithic lithium disilicate restorations: One-year results of a split-mouth randomized controlled clinical trial</atitle><jtitle>The Journal of prosthetic dentistry</jtitle><addtitle>J Prosthet Dent</addtitle><date>2024-01</date><risdate>2024</risdate><volume>131</volume><issue>1</issue><spage>25</spage><epage>33</epage><pages>25-33</pages><issn>0022-3913</issn><eissn>1097-6841</eissn><abstract>Selecting the optimal polishing procedure to reestablish surface smoothness after occlusal adjustment is essential for the long-term success of glass-ceramic restorations. While in vitro studies have shown different effective polishing protocols, clinical trials are lacking.
The purpose of this split-mouth controlled clinical trial was to evaluate the effectiveness of 2 polishing systems in reestablishing the surface smoothness of posterior monolithic lithium disilicate ceramic restorations.
Ninety-six restorations that required occlusal adjustment after bonding were randomized into 2 groups: Forty-eight restorations were polished by using the Exa Cerapol polishing kit, and the other 48 restorations were polished by using the Shofu polishing kit. The restorations were replicated with epoxy resin at 3 study times—after bonding (t1), after occlusal adjustment (t2), and after polishing (t3)—for quantitative roughness analysis (Ra). Representative specimens from each group were qualitatively analyzed by using a confocal laser microscope. Clinical analyses were performed after the polishing procedure and at 30, 180, and 365 days after the polishing procedure by following the United States Public Health Service (USPHS) criteria. ANOVA and the Tukey multiple comparisons parametric tests were computed (α=.05). The Kaplan-Meier test was used to analyze the survival rate of restorations.
No statistically significant difference was found between the Exa Cerapol and Shofu groups (P=.086). A statistically significant difference was found between study times t1 and t2 and between t2 and t3 (both P<.001) in both experimental groups. No statistically significant difference was found between study times t1 and t3 (P=.181) in either experimental group. For the clinical criterion “integrity of restorations,” all the elements analyzed indicated an alfa grade at all study times. The survival rate of the restorations was 100%.
Both polishing kits were effective in reestablishing the surface smoothness of restorations after occlusal adjustment.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>35272843</pmid><doi>10.1016/j.prosdent.2022.01.008</doi><tpages>9</tpages><orcidid>https://orcid.org/0000-0001-7788-0243</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0022-3913 |
ispartof | The Journal of prosthetic dentistry, 2024-01, Vol.131 (1), p.25-33 |
issn | 0022-3913 1097-6841 |
language | eng |
recordid | cdi_proquest_miscellaneous_2638728146 |
source | ScienceDirect Journals |
title | Efficacy of two polishing systems in reestablishing the surface smoothness of posterior monolithic lithium disilicate restorations: One-year results of a split-mouth randomized controlled clinical trial |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T05%3A47%3A02IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Efficacy%20of%20two%20polishing%20systems%20in%20reestablishing%20the%20surface%20smoothness%20of%20posterior%20monolithic%20lithium%20disilicate%20restorations:%20One-year%20results%20of%20a%20split-mouth%20randomized%20controlled%20clinical%20trial&rft.jtitle=The%20Journal%20of%20prosthetic%20dentistry&rft.au=Caixeta,%20Mariana%20Tassinari&rft.date=2024-01&rft.volume=131&rft.issue=1&rft.spage=25&rft.epage=33&rft.pages=25-33&rft.issn=0022-3913&rft.eissn=1097-6841&rft_id=info:doi/10.1016/j.prosdent.2022.01.008&rft_dat=%3Cproquest_cross%3E2638728146%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c315t-b01370740d2505bea274e493cfe37a7cc9db8efa3a27522cb7f8f4a4a36f91733%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2638728146&rft_id=info:pmid/35272843&rfr_iscdi=true |