Development of a microfluidic system structured on a modified polydimethylsiloxane device for the selection of bovine epididymal spermatozoa
Microfluidic systems are on the rise in several studies that evaluate reproductive cells. However, the material used for manufacturing can still be considered relatively expensive. The objective of this study was to develop a new microfluidic device, using a modified polydimethylsiloxane ((PDMS) Sil...
Saved in:
Published in: | Reproductive toxicology (Elmsford, N.Y.) N.Y.), 2022-06, Vol.110, p.1-8 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c368t-ea2278a17eb47087d7a4d84ce6bf44bed95042d415a1fd12bcffed0c1f285d273 |
---|---|
cites | cdi_FETCH-LOGICAL-c368t-ea2278a17eb47087d7a4d84ce6bf44bed95042d415a1fd12bcffed0c1f285d273 |
container_end_page | 8 |
container_issue | |
container_start_page | 1 |
container_title | Reproductive toxicology (Elmsford, N.Y.) |
container_volume | 110 |
creator | Fernandes, Beatriz Dantas dos Santos, Fernanda Araujo Bezerra, Luana Grasiele Pereira de Brito, Parmênedes Dias de Macêdo, Luã Barbalho da Silva, Alexandre Rodrigues Bezerra, Marcelo Barbosa |
description | Microfluidic systems are on the rise in several studies that evaluate reproductive cells. However, the material used for manufacturing can still be considered relatively expensive. The objective of this study was to develop a new microfluidic device, using a modified polydimethylsiloxane ((PDMS) Silpuran®), test its viability and carry out a selection of bovine sperm. Sperm was collected from epididymis (n = 10) and evaluated at different incubation times (60 min, 120 min, 180 min) to assess polydimethylsiloxane toxicity, where a tube was used as a control and the microfluidic device as treatment. An additional ten epididymis were used for the sperm selection test, which utilized four types of solutions: in vitro maturation medium (IVM) with and without oocyte, progesterone and saline solution (SS). The Percoll gradient was used as a control and the microfluidic device as treatment. The kinetic parameters of sperm were evaluated using the computer-assisted semen analysis (CASA). Morphology was performed with Bengal Rose, the integrity, and viability of the sperm using the hypoosmotic test and fluorescent microscopy probes, respectively. Mann-Whitney test was used in the first experiment, Kruskall-Wallis variance analysis tests with post hoc and Student-Newman-Keuls used in the second experiment. Regarding the non-toxic effects, most motility parameters demonstrated the superiority of the microfluidic device compared to the control. In the second experiment, the sperm showed equivalence between the microfluidic device and the Percoll gradient Silpuran® PDMS was not toxic to the cells and can be efficient for selecting bovine sperm, achieving better results in a medium for IVM with or without oocytes.
•Polydimethylsiloxane Silpuran is not toxic to bovine sperm.•Bovine sperm are attracted by in vitro maturation medium with and without oocytes.•Medroxyprogesterone acetate did not present chemoattractive action to bovine sperm. |
doi_str_mv | 10.1016/j.reprotox.2022.03.005 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2641500508</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0890623822000314</els_id><sourcerecordid>2641500508</sourcerecordid><originalsourceid>FETCH-LOGICAL-c368t-ea2278a17eb47087d7a4d84ce6bf44bed95042d415a1fd12bcffed0c1f285d273</originalsourceid><addsrcrecordid>eNqFkc2OFCEUhYnROO3oK0xYuqkSqD96pxl_k0nc6JpQcMnQgaYEqjPlM_jQ3k7PuHVFbvKdc7nnEHLDWcsZH98d2gxLTjU9tIIJ0bKuZWx4RnZcTl3DJyafkx2Te9aMopNX5FUpB8ZYP-2nl-SqGzo2IrQjfz7CCUJaIhwrTY5qGr3JyYXVW29o2UqFSEvNq6lrBkvT8cwk653HaUlhsz5Cvd9C8SE96CNQCydvgLqUab0HWiCAqR6F6D-nk0cEFrS3W9SBlgVy1DX9Tvo1eeF0KPDm8b0mPz9_-nH7tbn7_uXb7Ye7xnSjrA1oISap-QRzj4dOdtK9lb2BcXZ9P4PdD6wXtueD5s5yMRvnwDLDnZCDFVN3Td5efDHBXyuUqqIvBkLA36e1KDGiFuNkEtHxgmIopWRwask-6rwpztS5CXVQT02ocxOKdQqlKLx53LHOEew_2VP0CLy_AICXnjxkVYyHowHrM-albPL_2_EXil2i5g</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2641500508</pqid></control><display><type>article</type><title>Development of a microfluidic system structured on a modified polydimethylsiloxane device for the selection of bovine epididymal spermatozoa</title><source>Elsevier</source><creator>Fernandes, Beatriz Dantas ; dos Santos, Fernanda Araujo ; Bezerra, Luana Grasiele Pereira ; de Brito, Parmênedes Dias ; de Macêdo, Luã Barbalho ; da Silva, Alexandre Rodrigues ; Bezerra, Marcelo Barbosa</creator><creatorcontrib>Fernandes, Beatriz Dantas ; dos Santos, Fernanda Araujo ; Bezerra, Luana Grasiele Pereira ; de Brito, Parmênedes Dias ; de Macêdo, Luã Barbalho ; da Silva, Alexandre Rodrigues ; Bezerra, Marcelo Barbosa</creatorcontrib><description>Microfluidic systems are on the rise in several studies that evaluate reproductive cells. However, the material used for manufacturing can still be considered relatively expensive. The objective of this study was to develop a new microfluidic device, using a modified polydimethylsiloxane ((PDMS) Silpuran®), test its viability and carry out a selection of bovine sperm. Sperm was collected from epididymis (n = 10) and evaluated at different incubation times (60 min, 120 min, 180 min) to assess polydimethylsiloxane toxicity, where a tube was used as a control and the microfluidic device as treatment. An additional ten epididymis were used for the sperm selection test, which utilized four types of solutions: in vitro maturation medium (IVM) with and without oocyte, progesterone and saline solution (SS). The Percoll gradient was used as a control and the microfluidic device as treatment. The kinetic parameters of sperm were evaluated using the computer-assisted semen analysis (CASA). Morphology was performed with Bengal Rose, the integrity, and viability of the sperm using the hypoosmotic test and fluorescent microscopy probes, respectively. Mann-Whitney test was used in the first experiment, Kruskall-Wallis variance analysis tests with post hoc and Student-Newman-Keuls used in the second experiment. Regarding the non-toxic effects, most motility parameters demonstrated the superiority of the microfluidic device compared to the control. In the second experiment, the sperm showed equivalence between the microfluidic device and the Percoll gradient Silpuran® PDMS was not toxic to the cells and can be efficient for selecting bovine sperm, achieving better results in a medium for IVM with or without oocytes.
•Polydimethylsiloxane Silpuran is not toxic to bovine sperm.•Bovine sperm are attracted by in vitro maturation medium with and without oocytes.•Medroxyprogesterone acetate did not present chemoattractive action to bovine sperm.</description><identifier>ISSN: 0890-6238</identifier><identifier>EISSN: 1873-1708</identifier><identifier>DOI: 10.1016/j.reprotox.2022.03.005</identifier><identifier>PMID: 35306170</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Epididymis ; Integrity ; Microfluidic device ; Morphology ; Polydimethylsiloxane ; Sperm selection</subject><ispartof>Reproductive toxicology (Elmsford, N.Y.), 2022-06, Vol.110, p.1-8</ispartof><rights>2022</rights><rights>Copyright © 2022. Published by Elsevier Inc.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c368t-ea2278a17eb47087d7a4d84ce6bf44bed95042d415a1fd12bcffed0c1f285d273</citedby><cites>FETCH-LOGICAL-c368t-ea2278a17eb47087d7a4d84ce6bf44bed95042d415a1fd12bcffed0c1f285d273</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/35306170$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Fernandes, Beatriz Dantas</creatorcontrib><creatorcontrib>dos Santos, Fernanda Araujo</creatorcontrib><creatorcontrib>Bezerra, Luana Grasiele Pereira</creatorcontrib><creatorcontrib>de Brito, Parmênedes Dias</creatorcontrib><creatorcontrib>de Macêdo, Luã Barbalho</creatorcontrib><creatorcontrib>da Silva, Alexandre Rodrigues</creatorcontrib><creatorcontrib>Bezerra, Marcelo Barbosa</creatorcontrib><title>Development of a microfluidic system structured on a modified polydimethylsiloxane device for the selection of bovine epididymal spermatozoa</title><title>Reproductive toxicology (Elmsford, N.Y.)</title><addtitle>Reprod Toxicol</addtitle><description>Microfluidic systems are on the rise in several studies that evaluate reproductive cells. However, the material used for manufacturing can still be considered relatively expensive. The objective of this study was to develop a new microfluidic device, using a modified polydimethylsiloxane ((PDMS) Silpuran®), test its viability and carry out a selection of bovine sperm. Sperm was collected from epididymis (n = 10) and evaluated at different incubation times (60 min, 120 min, 180 min) to assess polydimethylsiloxane toxicity, where a tube was used as a control and the microfluidic device as treatment. An additional ten epididymis were used for the sperm selection test, which utilized four types of solutions: in vitro maturation medium (IVM) with and without oocyte, progesterone and saline solution (SS). The Percoll gradient was used as a control and the microfluidic device as treatment. The kinetic parameters of sperm were evaluated using the computer-assisted semen analysis (CASA). Morphology was performed with Bengal Rose, the integrity, and viability of the sperm using the hypoosmotic test and fluorescent microscopy probes, respectively. Mann-Whitney test was used in the first experiment, Kruskall-Wallis variance analysis tests with post hoc and Student-Newman-Keuls used in the second experiment. Regarding the non-toxic effects, most motility parameters demonstrated the superiority of the microfluidic device compared to the control. In the second experiment, the sperm showed equivalence between the microfluidic device and the Percoll gradient Silpuran® PDMS was not toxic to the cells and can be efficient for selecting bovine sperm, achieving better results in a medium for IVM with or without oocytes.
•Polydimethylsiloxane Silpuran is not toxic to bovine sperm.•Bovine sperm are attracted by in vitro maturation medium with and without oocytes.•Medroxyprogesterone acetate did not present chemoattractive action to bovine sperm.</description><subject>Epididymis</subject><subject>Integrity</subject><subject>Microfluidic device</subject><subject>Morphology</subject><subject>Polydimethylsiloxane</subject><subject>Sperm selection</subject><issn>0890-6238</issn><issn>1873-1708</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNqFkc2OFCEUhYnROO3oK0xYuqkSqD96pxl_k0nc6JpQcMnQgaYEqjPlM_jQ3k7PuHVFbvKdc7nnEHLDWcsZH98d2gxLTjU9tIIJ0bKuZWx4RnZcTl3DJyafkx2Te9aMopNX5FUpB8ZYP-2nl-SqGzo2IrQjfz7CCUJaIhwrTY5qGr3JyYXVW29o2UqFSEvNq6lrBkvT8cwk653HaUlhsz5Cvd9C8SE96CNQCydvgLqUab0HWiCAqR6F6D-nk0cEFrS3W9SBlgVy1DX9Tvo1eeF0KPDm8b0mPz9_-nH7tbn7_uXb7Ye7xnSjrA1oISap-QRzj4dOdtK9lb2BcXZ9P4PdD6wXtueD5s5yMRvnwDLDnZCDFVN3Td5efDHBXyuUqqIvBkLA36e1KDGiFuNkEtHxgmIopWRwask-6rwpztS5CXVQT02ocxOKdQqlKLx53LHOEew_2VP0CLy_AICXnjxkVYyHowHrM-albPL_2_EXil2i5g</recordid><startdate>202206</startdate><enddate>202206</enddate><creator>Fernandes, Beatriz Dantas</creator><creator>dos Santos, Fernanda Araujo</creator><creator>Bezerra, Luana Grasiele Pereira</creator><creator>de Brito, Parmênedes Dias</creator><creator>de Macêdo, Luã Barbalho</creator><creator>da Silva, Alexandre Rodrigues</creator><creator>Bezerra, Marcelo Barbosa</creator><general>Elsevier Inc</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>202206</creationdate><title>Development of a microfluidic system structured on a modified polydimethylsiloxane device for the selection of bovine epididymal spermatozoa</title><author>Fernandes, Beatriz Dantas ; dos Santos, Fernanda Araujo ; Bezerra, Luana Grasiele Pereira ; de Brito, Parmênedes Dias ; de Macêdo, Luã Barbalho ; da Silva, Alexandre Rodrigues ; Bezerra, Marcelo Barbosa</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c368t-ea2278a17eb47087d7a4d84ce6bf44bed95042d415a1fd12bcffed0c1f285d273</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Epididymis</topic><topic>Integrity</topic><topic>Microfluidic device</topic><topic>Morphology</topic><topic>Polydimethylsiloxane</topic><topic>Sperm selection</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Fernandes, Beatriz Dantas</creatorcontrib><creatorcontrib>dos Santos, Fernanda Araujo</creatorcontrib><creatorcontrib>Bezerra, Luana Grasiele Pereira</creatorcontrib><creatorcontrib>de Brito, Parmênedes Dias</creatorcontrib><creatorcontrib>de Macêdo, Luã Barbalho</creatorcontrib><creatorcontrib>da Silva, Alexandre Rodrigues</creatorcontrib><creatorcontrib>Bezerra, Marcelo Barbosa</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Reproductive toxicology (Elmsford, N.Y.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Fernandes, Beatriz Dantas</au><au>dos Santos, Fernanda Araujo</au><au>Bezerra, Luana Grasiele Pereira</au><au>de Brito, Parmênedes Dias</au><au>de Macêdo, Luã Barbalho</au><au>da Silva, Alexandre Rodrigues</au><au>Bezerra, Marcelo Barbosa</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development of a microfluidic system structured on a modified polydimethylsiloxane device for the selection of bovine epididymal spermatozoa</atitle><jtitle>Reproductive toxicology (Elmsford, N.Y.)</jtitle><addtitle>Reprod Toxicol</addtitle><date>2022-06</date><risdate>2022</risdate><volume>110</volume><spage>1</spage><epage>8</epage><pages>1-8</pages><issn>0890-6238</issn><eissn>1873-1708</eissn><abstract>Microfluidic systems are on the rise in several studies that evaluate reproductive cells. However, the material used for manufacturing can still be considered relatively expensive. The objective of this study was to develop a new microfluidic device, using a modified polydimethylsiloxane ((PDMS) Silpuran®), test its viability and carry out a selection of bovine sperm. Sperm was collected from epididymis (n = 10) and evaluated at different incubation times (60 min, 120 min, 180 min) to assess polydimethylsiloxane toxicity, where a tube was used as a control and the microfluidic device as treatment. An additional ten epididymis were used for the sperm selection test, which utilized four types of solutions: in vitro maturation medium (IVM) with and without oocyte, progesterone and saline solution (SS). The Percoll gradient was used as a control and the microfluidic device as treatment. The kinetic parameters of sperm were evaluated using the computer-assisted semen analysis (CASA). Morphology was performed with Bengal Rose, the integrity, and viability of the sperm using the hypoosmotic test and fluorescent microscopy probes, respectively. Mann-Whitney test was used in the first experiment, Kruskall-Wallis variance analysis tests with post hoc and Student-Newman-Keuls used in the second experiment. Regarding the non-toxic effects, most motility parameters demonstrated the superiority of the microfluidic device compared to the control. In the second experiment, the sperm showed equivalence between the microfluidic device and the Percoll gradient Silpuran® PDMS was not toxic to the cells and can be efficient for selecting bovine sperm, achieving better results in a medium for IVM with or without oocytes.
•Polydimethylsiloxane Silpuran is not toxic to bovine sperm.•Bovine sperm are attracted by in vitro maturation medium with and without oocytes.•Medroxyprogesterone acetate did not present chemoattractive action to bovine sperm.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>35306170</pmid><doi>10.1016/j.reprotox.2022.03.005</doi><tpages>8</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0890-6238 |
ispartof | Reproductive toxicology (Elmsford, N.Y.), 2022-06, Vol.110, p.1-8 |
issn | 0890-6238 1873-1708 |
language | eng |
recordid | cdi_proquest_miscellaneous_2641500508 |
source | Elsevier |
subjects | Epididymis Integrity Microfluidic device Morphology Polydimethylsiloxane Sperm selection |
title | Development of a microfluidic system structured on a modified polydimethylsiloxane device for the selection of bovine epididymal spermatozoa |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T17%3A19%3A41IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20of%20a%20microfluidic%20system%20structured%20on%20a%20modified%20polydimethylsiloxane%20device%20for%20the%20selection%20of%20bovine%20epididymal%20spermatozoa&rft.jtitle=Reproductive%20toxicology%20(Elmsford,%20N.Y.)&rft.au=Fernandes,%20Beatriz%20Dantas&rft.date=2022-06&rft.volume=110&rft.spage=1&rft.epage=8&rft.pages=1-8&rft.issn=0890-6238&rft.eissn=1873-1708&rft_id=info:doi/10.1016/j.reprotox.2022.03.005&rft_dat=%3Cproquest_cross%3E2641500508%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c368t-ea2278a17eb47087d7a4d84ce6bf44bed95042d415a1fd12bcffed0c1f285d273%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2641500508&rft_id=info:pmid/35306170&rfr_iscdi=true |