Loading…
Development and validation of a sensitive LC-MS/MS method for pioglitazone: application towards pharmacokinetic and tissue distribution study in rats
In the present study, a sensitive LC-MS/MS method was developed and validated to measure pioglitazone (PGZ) concentrations in rat plasma and tissues. The chromatographic separation was achieved by using a YMC Pro C 18 column (100 mm × 4.6 mm, 3μ) with a mobile phase consisting of formic acid (0.1% v...
Saved in:
Published in: | RSC advances 2021-03, Vol.11 (19), p.11437-11443 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | In the present study, a sensitive LC-MS/MS method was developed and validated to measure pioglitazone (PGZ) concentrations in rat plasma and tissues. The chromatographic separation was achieved by using a YMC Pro C
18
column (100 mm × 4.6 mm, 3μ) with a mobile phase consisting of formic acid (0.1% v/v) and acetonitrile (5 : 95) at a flow rate of 0.7 mL min
−1
and injection volume of 10 μL (IS: rosiglitazone). Mass spectrometric detection was done using triple quadrupole mass spectrometry using the ESI interface operating in a positive ionization mode. The developed method was validated over a linearity range of 1-500 ng mL
−1
with detection and a lower quantification limit of 0.5 ng mL
−1
and 1 ng mL
−1
. The method accuracy ranged from 95.89-98.78% (inter-day) & 93.39-97.68% (intra-day) with a precision range of 6.09-8.12% for inter-day & 7.55-9.87% for intra-day, respectively. The PGZ shows the highest
C
max
of 495.03 ng mL
−1
in plasma and the lowest
C
max
, 24.50 ± 2.71 ng mL
−1
in bone. The maximum
T
max
of 5.00 ± 0.49 h was observed in bone and a minimum of 1.01 ± 0.05 h in plasma. The AUC
(0-24 h and 0-
∞
)
values are highest in plasma (1056.58 ± 65.78 & 1069.38 ± 77.50 ng h
−1
mL
−1
) and lowest in brain (166.93 ± 15.70 &167.12 ± 16.77 ng h
−1
mL
−1
), and the
T
1/2
was highest in plasma (5.62 ± 0.74 h) and lowest in kidney (2.78 ± 0.19). The developed method was successfully used to measure the PGZ pharmacokinetic and tissue distribution. Further, the developed method could be utilized for validating target organ (adipose tissue) specific delivery of PGZ (nano-formulations) in addition to conventional dosage forms.
The developed method was investigated for target and off-target distribution of pioglitazone and could be applied to validate the site-specific delivery systems. |
---|---|
ISSN: | 2046-2069 2046-2069 |
DOI: | 10.1039/d1ra01126j |