Measurements of body impedance for ESD
High voltage, short duration electrostatic discharge (ESD) measurements of human body impedance have been accomplished for different paths through the body. Skin contact impedance and internal body impedance between various locations on the body were examined. Voltages from 1000 to 5000 V were appli...
Saved in:
Main Authors: | , , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | High voltage, short duration electrostatic discharge (ESD) measurements of human body impedance have been accomplished for different paths through the body. Skin contact impedance and internal body impedance between various locations on the body were examined. Voltages from 1000 to 5000 V were applied and the peak currents is 2.0 to 10A. The current waveform has time constant from 0.25 to 1.25 mu s. The short time constant is consistent with safety requirements. The body impedance between the palm of the hand and the sole of the feet was found to be about 520 to 550 Omega . |
---|---|