Loading…

Characterization of corrosion interfaces by the scanning Kelvin probe force microscopy technique

A variety of interfaces relevant to corrosion processes were examined by the scanning Kelvin probe force microscopy (SKPPM) technique in order to study the influences of various parameters on the measured potential. SKPFM measurements performed on AA2024-T3 after solution exposure showed that surfac...

Full description

Saved in:
Bibliographic Details
Published in:Journal of the Electrochemical Society 2001-05, Vol.148 (5), p.B163-B173
Main Authors: GUILLAUMIN, V, SCHMUTZ, P, FRANKEL, G. S
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c388t-ee6a175a90bec48b3d07b9acb2e37585b5af24aa759d368f2e2164b6035877f83
cites cdi_FETCH-LOGICAL-c388t-ee6a175a90bec48b3d07b9acb2e37585b5af24aa759d368f2e2164b6035877f83
container_end_page B173
container_issue 5
container_start_page B163
container_title Journal of the Electrochemical Society
container_volume 148
creator GUILLAUMIN, V
SCHMUTZ, P
FRANKEL, G. S
description A variety of interfaces relevant to corrosion processes were examined by the scanning Kelvin probe force microscopy (SKPPM) technique in order to study the influences of various parameters on the measured potential. SKPFM measurements performed on AA2024-T3 after solution exposure showed that surface composition is not the only parameter that controls the Volta potential difference, which is measured by SKPFM. The influence of surface oxide structure and adsorption at the oxide surface can be probed by SKPFM and lateral potential gradients can be observed in the absence of significant differences in oxide composition. The influence of tip-sample separation distance on the measured Volta potential difference was studied for different pure oxide-covered metals. SKPFM measurements were made in air on pure Ni and Pt samples withdrawn from solution at open circuit or under potential control. The Volta potential difference was found to be composed of a transient component that slowly discharged and a more permanent component associated with the charge of adsorbed species. The Volta potential difference transients measured on the samples emersed under potential control decayed much slower than the open-circuit potential transient measured in solution upon release of the potential control. These different measurements validate the use of SKPFM for the prediction of local corrosion sites and the study of surface modification during solution exposure.
doi_str_mv 10.1149/1.1359199
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_26665076</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>26665076</sourcerecordid><originalsourceid>FETCH-LOGICAL-c388t-ee6a175a90bec48b3d07b9acb2e37585b5af24aa759d368f2e2164b6035877f83</originalsourceid><addsrcrecordid>eNpNULtOAzEQtBBIhEDBH7hASBQHt-fXuUQRLxGJBurDdtbE6OIL9oEUvh5HSUG1Gu3M7OwQcg71NQDXN3ANTGjQ-oBMQHNRKQA4JJO6BlZxKeCYnOT8WSC0XE3I-2xpknEjpvBrxjBEOnjqhpSGvAUhlo03DjO1GzoukWZnYgzxgz5j_xMiXafBIvVDckhXwRWdG9aFim4Zw9c3npIjb_qMZ_s5JW_3d6-zx2r-8vA0u51XjrXtWCFKA0oYXVt0vLVsUSurjbMNMiVaYYXxDTdGCb1gsvUNNiC5lTUTrVK-ZVNyufMtgcrZPHarkB32vYk4fOeukVKKWslCvNoRt1lzQt-tU1iZtOmg7rYddtDtOyzci72pKX_3PpnoQv4n4E0jNPsDlaZxwQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>26665076</pqid></control><display><type>article</type><title>Characterization of corrosion interfaces by the scanning Kelvin probe force microscopy technique</title><source>Institute of Physics:Jisc Collections:IOP Publishing Read and Publish 2024-2025 (Reading List)</source><creator>GUILLAUMIN, V ; SCHMUTZ, P ; FRANKEL, G. S</creator><creatorcontrib>GUILLAUMIN, V ; SCHMUTZ, P ; FRANKEL, G. S</creatorcontrib><description>A variety of interfaces relevant to corrosion processes were examined by the scanning Kelvin probe force microscopy (SKPPM) technique in order to study the influences of various parameters on the measured potential. SKPFM measurements performed on AA2024-T3 after solution exposure showed that surface composition is not the only parameter that controls the Volta potential difference, which is measured by SKPFM. The influence of surface oxide structure and adsorption at the oxide surface can be probed by SKPFM and lateral potential gradients can be observed in the absence of significant differences in oxide composition. The influence of tip-sample separation distance on the measured Volta potential difference was studied for different pure oxide-covered metals. SKPFM measurements were made in air on pure Ni and Pt samples withdrawn from solution at open circuit or under potential control. The Volta potential difference was found to be composed of a transient component that slowly discharged and a more permanent component associated with the charge of adsorbed species. The Volta potential difference transients measured on the samples emersed under potential control decayed much slower than the open-circuit potential transient measured in solution upon release of the potential control. These different measurements validate the use of SKPFM for the prediction of local corrosion sites and the study of surface modification during solution exposure.</description><identifier>ISSN: 0013-4651</identifier><identifier>EISSN: 1945-7111</identifier><identifier>DOI: 10.1149/1.1359199</identifier><identifier>CODEN: JESOAN</identifier><language>eng</language><publisher>Pennington, NJ: Electrochemical Society</publisher><subject>Applied sciences ; Corrosion ; Corrosion mechanisms ; Exact sciences and technology ; Metals. Metallurgy</subject><ispartof>Journal of the Electrochemical Society, 2001-05, Vol.148 (5), p.B163-B173</ispartof><rights>2001 INIST-CNRS</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c388t-ee6a175a90bec48b3d07b9acb2e37585b5af24aa759d368f2e2164b6035877f83</citedby><cites>FETCH-LOGICAL-c388t-ee6a175a90bec48b3d07b9acb2e37585b5af24aa759d368f2e2164b6035877f83</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=1042259$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>GUILLAUMIN, V</creatorcontrib><creatorcontrib>SCHMUTZ, P</creatorcontrib><creatorcontrib>FRANKEL, G. S</creatorcontrib><title>Characterization of corrosion interfaces by the scanning Kelvin probe force microscopy technique</title><title>Journal of the Electrochemical Society</title><description>A variety of interfaces relevant to corrosion processes were examined by the scanning Kelvin probe force microscopy (SKPPM) technique in order to study the influences of various parameters on the measured potential. SKPFM measurements performed on AA2024-T3 after solution exposure showed that surface composition is not the only parameter that controls the Volta potential difference, which is measured by SKPFM. The influence of surface oxide structure and adsorption at the oxide surface can be probed by SKPFM and lateral potential gradients can be observed in the absence of significant differences in oxide composition. The influence of tip-sample separation distance on the measured Volta potential difference was studied for different pure oxide-covered metals. SKPFM measurements were made in air on pure Ni and Pt samples withdrawn from solution at open circuit or under potential control. The Volta potential difference was found to be composed of a transient component that slowly discharged and a more permanent component associated with the charge of adsorbed species. The Volta potential difference transients measured on the samples emersed under potential control decayed much slower than the open-circuit potential transient measured in solution upon release of the potential control. These different measurements validate the use of SKPFM for the prediction of local corrosion sites and the study of surface modification during solution exposure.</description><subject>Applied sciences</subject><subject>Corrosion</subject><subject>Corrosion mechanisms</subject><subject>Exact sciences and technology</subject><subject>Metals. Metallurgy</subject><issn>0013-4651</issn><issn>1945-7111</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2001</creationdate><recordtype>article</recordtype><recordid>eNpNULtOAzEQtBBIhEDBH7hASBQHt-fXuUQRLxGJBurDdtbE6OIL9oEUvh5HSUG1Gu3M7OwQcg71NQDXN3ANTGjQ-oBMQHNRKQA4JJO6BlZxKeCYnOT8WSC0XE3I-2xpknEjpvBrxjBEOnjqhpSGvAUhlo03DjO1GzoukWZnYgzxgz5j_xMiXafBIvVDckhXwRWdG9aFim4Zw9c3npIjb_qMZ_s5JW_3d6-zx2r-8vA0u51XjrXtWCFKA0oYXVt0vLVsUSurjbMNMiVaYYXxDTdGCb1gsvUNNiC5lTUTrVK-ZVNyufMtgcrZPHarkB32vYk4fOeukVKKWslCvNoRt1lzQt-tU1iZtOmg7rYddtDtOyzci72pKX_3PpnoQv4n4E0jNPsDlaZxwQ</recordid><startdate>20010501</startdate><enddate>20010501</enddate><creator>GUILLAUMIN, V</creator><creator>SCHMUTZ, P</creator><creator>FRANKEL, G. S</creator><general>Electrochemical Society</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7SE</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope></search><sort><creationdate>20010501</creationdate><title>Characterization of corrosion interfaces by the scanning Kelvin probe force microscopy technique</title><author>GUILLAUMIN, V ; SCHMUTZ, P ; FRANKEL, G. S</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c388t-ee6a175a90bec48b3d07b9acb2e37585b5af24aa759d368f2e2164b6035877f83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2001</creationdate><topic>Applied sciences</topic><topic>Corrosion</topic><topic>Corrosion mechanisms</topic><topic>Exact sciences and technology</topic><topic>Metals. Metallurgy</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>GUILLAUMIN, V</creatorcontrib><creatorcontrib>SCHMUTZ, P</creatorcontrib><creatorcontrib>FRANKEL, G. S</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Corrosion Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><jtitle>Journal of the Electrochemical Society</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>GUILLAUMIN, V</au><au>SCHMUTZ, P</au><au>FRANKEL, G. S</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Characterization of corrosion interfaces by the scanning Kelvin probe force microscopy technique</atitle><jtitle>Journal of the Electrochemical Society</jtitle><date>2001-05-01</date><risdate>2001</risdate><volume>148</volume><issue>5</issue><spage>B163</spage><epage>B173</epage><pages>B163-B173</pages><issn>0013-4651</issn><eissn>1945-7111</eissn><coden>JESOAN</coden><abstract>A variety of interfaces relevant to corrosion processes were examined by the scanning Kelvin probe force microscopy (SKPPM) technique in order to study the influences of various parameters on the measured potential. SKPFM measurements performed on AA2024-T3 after solution exposure showed that surface composition is not the only parameter that controls the Volta potential difference, which is measured by SKPFM. The influence of surface oxide structure and adsorption at the oxide surface can be probed by SKPFM and lateral potential gradients can be observed in the absence of significant differences in oxide composition. The influence of tip-sample separation distance on the measured Volta potential difference was studied for different pure oxide-covered metals. SKPFM measurements were made in air on pure Ni and Pt samples withdrawn from solution at open circuit or under potential control. The Volta potential difference was found to be composed of a transient component that slowly discharged and a more permanent component associated with the charge of adsorbed species. The Volta potential difference transients measured on the samples emersed under potential control decayed much slower than the open-circuit potential transient measured in solution upon release of the potential control. These different measurements validate the use of SKPFM for the prediction of local corrosion sites and the study of surface modification during solution exposure.</abstract><cop>Pennington, NJ</cop><pub>Electrochemical Society</pub><doi>10.1149/1.1359199</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0013-4651
ispartof Journal of the Electrochemical Society, 2001-05, Vol.148 (5), p.B163-B173
issn 0013-4651
1945-7111
language eng
recordid cdi_proquest_miscellaneous_26665076
source Institute of Physics:Jisc Collections:IOP Publishing Read and Publish 2024-2025 (Reading List)
subjects Applied sciences
Corrosion
Corrosion mechanisms
Exact sciences and technology
Metals. Metallurgy
title Characterization of corrosion interfaces by the scanning Kelvin probe force microscopy technique
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T16%3A54%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Characterization%20of%20corrosion%20interfaces%20by%20the%20scanning%20Kelvin%20probe%20force%20microscopy%20technique&rft.jtitle=Journal%20of%20the%20Electrochemical%20Society&rft.au=GUILLAUMIN,%20V&rft.date=2001-05-01&rft.volume=148&rft.issue=5&rft.spage=B163&rft.epage=B173&rft.pages=B163-B173&rft.issn=0013-4651&rft.eissn=1945-7111&rft.coden=JESOAN&rft_id=info:doi/10.1149/1.1359199&rft_dat=%3Cproquest_cross%3E26665076%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c388t-ee6a175a90bec48b3d07b9acb2e37585b5af24aa759d368f2e2164b6035877f83%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=26665076&rft_id=info:pmid/&rfr_iscdi=true