Loading…

Normal spectral emissivity of niobium (at 900 nm) by a pulse-heating reflectometric technique

The normal spectral emissivity of niobium strip specimens was measured using a new pulse-heating reflectometric technique. The hemispherical spectral reflectivity of the surface of a strip tangent to an integrating sphere is determined by a high-speed lock-in technique. At the same time, the radianc...

Full description

Saved in:
Bibliographic Details
Published in:International journal of thermophysics 1998-06, Vol.20 (4), p.1095-1106
Main Authors: Righini, F, Spisiak, J, Bussolino, G C
Format: Article
Language:English
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 1106
container_issue 4
container_start_page 1095
container_title International journal of thermophysics
container_volume 20
creator Righini, F
Spisiak, J
Bussolino, G C
description The normal spectral emissivity of niobium strip specimens was measured using a new pulse-heating reflectometric technique. The hemispherical spectral reflectivity of the surface of a strip tangent to an integrating sphere is determined by a high-speed lock-in technique. At the same time, the radiance temperature of the strip is measured by high-speed pyrometry from approximately 1000 K to the melting point. Details of the measurement method and of the related calibration techniques are reported. Results of the normal spectral emissivity of niobium at 900 nm from room temperature to its melting point are presented, discussing differences related to the heating rate and to surface conditions.
format article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_26691160</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>26691160</sourcerecordid><originalsourceid>FETCH-proquest_miscellaneous_266911603</originalsourceid><addsrcrecordid>eNqNjbsKwjAYhTMoWC_v8E-iQyFtsZpZFCcnBxcpafhrI7nUXIS-vRl8AKfzwfkOZ0IyWrBdzsrDfUbm3r8opWzPqow8rtZprsAPKIJLgFp6Lz8yjGA7MNK2MmrY8ACMUjB6C-0IHIaoPOY98iDNExx2Ku2txuCkgICiN_IdcUmmHU_i6pcLsj6fbsdLPjibah-a9CZQKW7QRt-Udc2KoqbV3-IXL-5GHw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>26691160</pqid></control><display><type>article</type><title>Normal spectral emissivity of niobium (at 900 nm) by a pulse-heating reflectometric technique</title><source>Springer Link</source><creator>Righini, F ; Spisiak, J ; Bussolino, G C</creator><creatorcontrib>Righini, F ; Spisiak, J ; Bussolino, G C</creatorcontrib><description>The normal spectral emissivity of niobium strip specimens was measured using a new pulse-heating reflectometric technique. The hemispherical spectral reflectivity of the surface of a strip tangent to an integrating sphere is determined by a high-speed lock-in technique. At the same time, the radiance temperature of the strip is measured by high-speed pyrometry from approximately 1000 K to the melting point. Details of the measurement method and of the related calibration techniques are reported. Results of the normal spectral emissivity of niobium at 900 nm from room temperature to its melting point are presented, discussing differences related to the heating rate and to surface conditions.</description><identifier>ISSN: 0195-928X</identifier><language>eng</language><ispartof>International journal of thermophysics, 1998-06, Vol.20 (4), p.1095-1106</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780</link.rule.ids></links><search><creatorcontrib>Righini, F</creatorcontrib><creatorcontrib>Spisiak, J</creatorcontrib><creatorcontrib>Bussolino, G C</creatorcontrib><title>Normal spectral emissivity of niobium (at 900 nm) by a pulse-heating reflectometric technique</title><title>International journal of thermophysics</title><description>The normal spectral emissivity of niobium strip specimens was measured using a new pulse-heating reflectometric technique. The hemispherical spectral reflectivity of the surface of a strip tangent to an integrating sphere is determined by a high-speed lock-in technique. At the same time, the radiance temperature of the strip is measured by high-speed pyrometry from approximately 1000 K to the melting point. Details of the measurement method and of the related calibration techniques are reported. Results of the normal spectral emissivity of niobium at 900 nm from room temperature to its melting point are presented, discussing differences related to the heating rate and to surface conditions.</description><issn>0195-928X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><recordid>eNqNjbsKwjAYhTMoWC_v8E-iQyFtsZpZFCcnBxcpafhrI7nUXIS-vRl8AKfzwfkOZ0IyWrBdzsrDfUbm3r8opWzPqow8rtZprsAPKIJLgFp6Lz8yjGA7MNK2MmrY8ACMUjB6C-0IHIaoPOY98iDNExx2Ku2txuCkgICiN_IdcUmmHU_i6pcLsj6fbsdLPjibah-a9CZQKW7QRt-Udc2KoqbV3-IXL-5GHw</recordid><startdate>19980616</startdate><enddate>19980616</enddate><creator>Righini, F</creator><creator>Spisiak, J</creator><creator>Bussolino, G C</creator><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope></search><sort><creationdate>19980616</creationdate><title>Normal spectral emissivity of niobium (at 900 nm) by a pulse-heating reflectometric technique</title><author>Righini, F ; Spisiak, J ; Bussolino, G C</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_miscellaneous_266911603</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Righini, F</creatorcontrib><creatorcontrib>Spisiak, J</creatorcontrib><creatorcontrib>Bussolino, G C</creatorcontrib><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><jtitle>International journal of thermophysics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Righini, F</au><au>Spisiak, J</au><au>Bussolino, G C</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Normal spectral emissivity of niobium (at 900 nm) by a pulse-heating reflectometric technique</atitle><jtitle>International journal of thermophysics</jtitle><date>1998-06-16</date><risdate>1998</risdate><volume>20</volume><issue>4</issue><spage>1095</spage><epage>1106</epage><pages>1095-1106</pages><issn>0195-928X</issn><abstract>The normal spectral emissivity of niobium strip specimens was measured using a new pulse-heating reflectometric technique. The hemispherical spectral reflectivity of the surface of a strip tangent to an integrating sphere is determined by a high-speed lock-in technique. At the same time, the radiance temperature of the strip is measured by high-speed pyrometry from approximately 1000 K to the melting point. Details of the measurement method and of the related calibration techniques are reported. Results of the normal spectral emissivity of niobium at 900 nm from room temperature to its melting point are presented, discussing differences related to the heating rate and to surface conditions.</abstract></addata></record>
fulltext fulltext
identifier ISSN: 0195-928X
ispartof International journal of thermophysics, 1998-06, Vol.20 (4), p.1095-1106
issn 0195-928X
language eng
recordid cdi_proquest_miscellaneous_26691160
source Springer Link
title Normal spectral emissivity of niobium (at 900 nm) by a pulse-heating reflectometric technique
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-10T16%3A32%3A38IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Normal%20spectral%20emissivity%20of%20niobium%20(at%20900%20nm)%20by%20a%20pulse-heating%20reflectometric%20technique&rft.jtitle=International%20journal%20of%20thermophysics&rft.au=Righini,%20F&rft.date=1998-06-16&rft.volume=20&rft.issue=4&rft.spage=1095&rft.epage=1106&rft.pages=1095-1106&rft.issn=0195-928X&rft_id=info:doi/&rft_dat=%3Cproquest%3E26691160%3C/proquest%3E%3Cgrp_id%3Ecdi_FETCH-proquest_miscellaneous_266911603%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=26691160&rft_id=info:pmid/&rfr_iscdi=true