Loading…

Feasibility and accuracy of laryngeal ultrasound for the assessment of vocal cord mobility in children

Transcutaneous laryngeal ultrasonography has been utilized to document vocal cord mobility in the adult perioperative thyroidectomy setting with variable success. The aims of this study were to assess the feasibility of using transcutaneous ultrasound in vocal cord visualization in children, to dete...

Full description

Saved in:
Bibliographic Details
Published in:International journal of pediatric otorhinolaryngology 2022-08, Vol.159, p.111193-111193, Article 111193
Main Authors: Friesen, Tzyynong L., Cahill, Gabrielle L., Brigger, Matthew T., Naheedy, John, Zhang, Xinlian, Jiang, Wen
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c339t-aa3dc7c7365664297bc8a61c41206e5d0f0ada65ee7d6a731c4344214f2fe4293
cites cdi_FETCH-LOGICAL-c339t-aa3dc7c7365664297bc8a61c41206e5d0f0ada65ee7d6a731c4344214f2fe4293
container_end_page 111193
container_issue
container_start_page 111193
container_title International journal of pediatric otorhinolaryngology
container_volume 159
creator Friesen, Tzyynong L.
Cahill, Gabrielle L.
Brigger, Matthew T.
Naheedy, John
Zhang, Xinlian
Jiang, Wen
description Transcutaneous laryngeal ultrasonography has been utilized to document vocal cord mobility in the adult perioperative thyroidectomy setting with variable success. The aims of this study were to assess the feasibility of using transcutaneous ultrasound in vocal cord visualization in children, to determine the accuracy in detecting vocal cord immobility compare to flexible laryngoscopy, and to identify any barriers that may affect its utility. This is a prospective blinded-assessor study. Transcutaneous laryngeal ultrasound and flexible laryngoscopy were performed in two pediatric settings: perioperative thyroid surgery and inpatient consultation for airway, voice, or swallowing concerns. The video recordings of ultrasound and laryngoscopy were assessed by two fellowship-trained pediatric otolaryngologists independently. A total of 83 paired laryngoscopy and ultrasound assessments were performed, 39 for perioperative thyroidectomy and 44 for inpatient consultation. The majority had normal vocal cord mobility (65/83, 78%), while 16 had unilateral cord palsy and 2 had bilateral palsy. The vocal cords were successfully visualized on ultrasound in 82/83 (99%) evaluations. Compared to gold standard laryngoscopy, the sensitivity for diagnosing vocal cord palsy on ultrasound was 53–83%, and the specificity was 97–98%. The sensitivity for detecting asymmetric vocal cord movement was 56–88%, and the specificity was 99%. The agreement between ultrasound and laryngoscopy diagnoses were 87–94% (κ = 0.58–0.83, moderate to near perfect agreement). The intra-rater agreement was 95–100% (κ = 0.64–1.0), and inter-rater agreement was 90% (κ = 0.66). Both subjects with bilateral vocal cord palsy had incorrect ultrasound diagnoses by both observers. We were able to utilize transcutaneous laryngeal ultrasound to successfully visualize vocal cord mobility in almost all pediatric patients with a high degree of specificity. The modality has limitations in the assessment of bilateral vocal cord palsy, and its sensitivity was observer-dependent. 4.
doi_str_mv 10.1016/j.ijporl.2022.111193
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2679236491</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0165587622001549</els_id><sourcerecordid>2679236491</sourcerecordid><originalsourceid>FETCH-LOGICAL-c339t-aa3dc7c7365664297bc8a61c41206e5d0f0ada65ee7d6a731c4344214f2fe4293</originalsourceid><addsrcrecordid>eNp9kE1LAzEQhoMoWKv_wEOOXnbN1ybdiyDFLyh40XNIk1mbkm5qslvovzdle3Yuc5jnfWEehO4pqSmh8nFb--0-plAzwlhNy7T8As3oQrFqIaS4RLOCNVWzUPIa3eS8JYQq0jQz1L2CyX7tgx-O2PQOG2vHZOwRxw4Hk479D5iAxzAkk-NYgC4mPGwAm5wh5x30wwk9RFswG5PDu3iu8z22Gx9cgv4WXXUmZLg77zn6fn35Wr5Xq8-3j-XzqrKct0NlDHdWWcVlI6VgrVrbhZHUCsqIhMaRjhhnZAOgnDSKlwsXglHRsQ4Kz-foYerdp_g7Qh70zmcLIZge4pg1k6plXIqWFlRMqE0x5wSd3ie_Kx9rSvRJq97qSas-adWT1hJ7mmJQ3jh4SDpbD70F5xPYQbvo_y_4AwUwhAU</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2679236491</pqid></control><display><type>article</type><title>Feasibility and accuracy of laryngeal ultrasound for the assessment of vocal cord mobility in children</title><source>ScienceDirect Journals</source><creator>Friesen, Tzyynong L. ; Cahill, Gabrielle L. ; Brigger, Matthew T. ; Naheedy, John ; Zhang, Xinlian ; Jiang, Wen</creator><creatorcontrib>Friesen, Tzyynong L. ; Cahill, Gabrielle L. ; Brigger, Matthew T. ; Naheedy, John ; Zhang, Xinlian ; Jiang, Wen</creatorcontrib><description>Transcutaneous laryngeal ultrasonography has been utilized to document vocal cord mobility in the adult perioperative thyroidectomy setting with variable success. The aims of this study were to assess the feasibility of using transcutaneous ultrasound in vocal cord visualization in children, to determine the accuracy in detecting vocal cord immobility compare to flexible laryngoscopy, and to identify any barriers that may affect its utility. This is a prospective blinded-assessor study. Transcutaneous laryngeal ultrasound and flexible laryngoscopy were performed in two pediatric settings: perioperative thyroid surgery and inpatient consultation for airway, voice, or swallowing concerns. The video recordings of ultrasound and laryngoscopy were assessed by two fellowship-trained pediatric otolaryngologists independently. A total of 83 paired laryngoscopy and ultrasound assessments were performed, 39 for perioperative thyroidectomy and 44 for inpatient consultation. The majority had normal vocal cord mobility (65/83, 78%), while 16 had unilateral cord palsy and 2 had bilateral palsy. The vocal cords were successfully visualized on ultrasound in 82/83 (99%) evaluations. Compared to gold standard laryngoscopy, the sensitivity for diagnosing vocal cord palsy on ultrasound was 53–83%, and the specificity was 97–98%. The sensitivity for detecting asymmetric vocal cord movement was 56–88%, and the specificity was 99%. The agreement between ultrasound and laryngoscopy diagnoses were 87–94% (κ = 0.58–0.83, moderate to near perfect agreement). The intra-rater agreement was 95–100% (κ = 0.64–1.0), and inter-rater agreement was 90% (κ = 0.66). Both subjects with bilateral vocal cord palsy had incorrect ultrasound diagnoses by both observers. We were able to utilize transcutaneous laryngeal ultrasound to successfully visualize vocal cord mobility in almost all pediatric patients with a high degree of specificity. The modality has limitations in the assessment of bilateral vocal cord palsy, and its sensitivity was observer-dependent. 4.</description><identifier>ISSN: 0165-5876</identifier><identifier>EISSN: 1872-8464</identifier><identifier>DOI: 10.1016/j.ijporl.2022.111193</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Laryngeal ultrasound ; Pediatric otolaryngology ; Thyroidectomy ; Vocal cord mobility ; Vocal cord paralysis</subject><ispartof>International journal of pediatric otorhinolaryngology, 2022-08, Vol.159, p.111193-111193, Article 111193</ispartof><rights>2022</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c339t-aa3dc7c7365664297bc8a61c41206e5d0f0ada65ee7d6a731c4344214f2fe4293</citedby><cites>FETCH-LOGICAL-c339t-aa3dc7c7365664297bc8a61c41206e5d0f0ada65ee7d6a731c4344214f2fe4293</cites><orcidid>0000-0003-1879-4868 ; 0000-0002-3916-8826 ; 0000-0002-6557-6989 ; 0000-0002-3528-1696</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Friesen, Tzyynong L.</creatorcontrib><creatorcontrib>Cahill, Gabrielle L.</creatorcontrib><creatorcontrib>Brigger, Matthew T.</creatorcontrib><creatorcontrib>Naheedy, John</creatorcontrib><creatorcontrib>Zhang, Xinlian</creatorcontrib><creatorcontrib>Jiang, Wen</creatorcontrib><title>Feasibility and accuracy of laryngeal ultrasound for the assessment of vocal cord mobility in children</title><title>International journal of pediatric otorhinolaryngology</title><description>Transcutaneous laryngeal ultrasonography has been utilized to document vocal cord mobility in the adult perioperative thyroidectomy setting with variable success. The aims of this study were to assess the feasibility of using transcutaneous ultrasound in vocal cord visualization in children, to determine the accuracy in detecting vocal cord immobility compare to flexible laryngoscopy, and to identify any barriers that may affect its utility. This is a prospective blinded-assessor study. Transcutaneous laryngeal ultrasound and flexible laryngoscopy were performed in two pediatric settings: perioperative thyroid surgery and inpatient consultation for airway, voice, or swallowing concerns. The video recordings of ultrasound and laryngoscopy were assessed by two fellowship-trained pediatric otolaryngologists independently. A total of 83 paired laryngoscopy and ultrasound assessments were performed, 39 for perioperative thyroidectomy and 44 for inpatient consultation. The majority had normal vocal cord mobility (65/83, 78%), while 16 had unilateral cord palsy and 2 had bilateral palsy. The vocal cords were successfully visualized on ultrasound in 82/83 (99%) evaluations. Compared to gold standard laryngoscopy, the sensitivity for diagnosing vocal cord palsy on ultrasound was 53–83%, and the specificity was 97–98%. The sensitivity for detecting asymmetric vocal cord movement was 56–88%, and the specificity was 99%. The agreement between ultrasound and laryngoscopy diagnoses were 87–94% (κ = 0.58–0.83, moderate to near perfect agreement). The intra-rater agreement was 95–100% (κ = 0.64–1.0), and inter-rater agreement was 90% (κ = 0.66). Both subjects with bilateral vocal cord palsy had incorrect ultrasound diagnoses by both observers. We were able to utilize transcutaneous laryngeal ultrasound to successfully visualize vocal cord mobility in almost all pediatric patients with a high degree of specificity. The modality has limitations in the assessment of bilateral vocal cord palsy, and its sensitivity was observer-dependent. 4.</description><subject>Laryngeal ultrasound</subject><subject>Pediatric otolaryngology</subject><subject>Thyroidectomy</subject><subject>Vocal cord mobility</subject><subject>Vocal cord paralysis</subject><issn>0165-5876</issn><issn>1872-8464</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNp9kE1LAzEQhoMoWKv_wEOOXnbN1ybdiyDFLyh40XNIk1mbkm5qslvovzdle3Yuc5jnfWEehO4pqSmh8nFb--0-plAzwlhNy7T8As3oQrFqIaS4RLOCNVWzUPIa3eS8JYQq0jQz1L2CyX7tgx-O2PQOG2vHZOwRxw4Hk479D5iAxzAkk-NYgC4mPGwAm5wh5x30wwk9RFswG5PDu3iu8z22Gx9cgv4WXXUmZLg77zn6fn35Wr5Xq8-3j-XzqrKct0NlDHdWWcVlI6VgrVrbhZHUCsqIhMaRjhhnZAOgnDSKlwsXglHRsQ4Kz-foYerdp_g7Qh70zmcLIZge4pg1k6plXIqWFlRMqE0x5wSd3ie_Kx9rSvRJq97qSas-adWT1hJ7mmJQ3jh4SDpbD70F5xPYQbvo_y_4AwUwhAU</recordid><startdate>202208</startdate><enddate>202208</enddate><creator>Friesen, Tzyynong L.</creator><creator>Cahill, Gabrielle L.</creator><creator>Brigger, Matthew T.</creator><creator>Naheedy, John</creator><creator>Zhang, Xinlian</creator><creator>Jiang, Wen</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-1879-4868</orcidid><orcidid>https://orcid.org/0000-0002-3916-8826</orcidid><orcidid>https://orcid.org/0000-0002-6557-6989</orcidid><orcidid>https://orcid.org/0000-0002-3528-1696</orcidid></search><sort><creationdate>202208</creationdate><title>Feasibility and accuracy of laryngeal ultrasound for the assessment of vocal cord mobility in children</title><author>Friesen, Tzyynong L. ; Cahill, Gabrielle L. ; Brigger, Matthew T. ; Naheedy, John ; Zhang, Xinlian ; Jiang, Wen</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c339t-aa3dc7c7365664297bc8a61c41206e5d0f0ada65ee7d6a731c4344214f2fe4293</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Laryngeal ultrasound</topic><topic>Pediatric otolaryngology</topic><topic>Thyroidectomy</topic><topic>Vocal cord mobility</topic><topic>Vocal cord paralysis</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Friesen, Tzyynong L.</creatorcontrib><creatorcontrib>Cahill, Gabrielle L.</creatorcontrib><creatorcontrib>Brigger, Matthew T.</creatorcontrib><creatorcontrib>Naheedy, John</creatorcontrib><creatorcontrib>Zhang, Xinlian</creatorcontrib><creatorcontrib>Jiang, Wen</creatorcontrib><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>International journal of pediatric otorhinolaryngology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Friesen, Tzyynong L.</au><au>Cahill, Gabrielle L.</au><au>Brigger, Matthew T.</au><au>Naheedy, John</au><au>Zhang, Xinlian</au><au>Jiang, Wen</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Feasibility and accuracy of laryngeal ultrasound for the assessment of vocal cord mobility in children</atitle><jtitle>International journal of pediatric otorhinolaryngology</jtitle><date>2022-08</date><risdate>2022</risdate><volume>159</volume><spage>111193</spage><epage>111193</epage><pages>111193-111193</pages><artnum>111193</artnum><issn>0165-5876</issn><eissn>1872-8464</eissn><abstract>Transcutaneous laryngeal ultrasonography has been utilized to document vocal cord mobility in the adult perioperative thyroidectomy setting with variable success. The aims of this study were to assess the feasibility of using transcutaneous ultrasound in vocal cord visualization in children, to determine the accuracy in detecting vocal cord immobility compare to flexible laryngoscopy, and to identify any barriers that may affect its utility. This is a prospective blinded-assessor study. Transcutaneous laryngeal ultrasound and flexible laryngoscopy were performed in two pediatric settings: perioperative thyroid surgery and inpatient consultation for airway, voice, or swallowing concerns. The video recordings of ultrasound and laryngoscopy were assessed by two fellowship-trained pediatric otolaryngologists independently. A total of 83 paired laryngoscopy and ultrasound assessments were performed, 39 for perioperative thyroidectomy and 44 for inpatient consultation. The majority had normal vocal cord mobility (65/83, 78%), while 16 had unilateral cord palsy and 2 had bilateral palsy. The vocal cords were successfully visualized on ultrasound in 82/83 (99%) evaluations. Compared to gold standard laryngoscopy, the sensitivity for diagnosing vocal cord palsy on ultrasound was 53–83%, and the specificity was 97–98%. The sensitivity for detecting asymmetric vocal cord movement was 56–88%, and the specificity was 99%. The agreement between ultrasound and laryngoscopy diagnoses were 87–94% (κ = 0.58–0.83, moderate to near perfect agreement). The intra-rater agreement was 95–100% (κ = 0.64–1.0), and inter-rater agreement was 90% (κ = 0.66). Both subjects with bilateral vocal cord palsy had incorrect ultrasound diagnoses by both observers. We were able to utilize transcutaneous laryngeal ultrasound to successfully visualize vocal cord mobility in almost all pediatric patients with a high degree of specificity. The modality has limitations in the assessment of bilateral vocal cord palsy, and its sensitivity was observer-dependent. 4.</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.ijporl.2022.111193</doi><tpages>1</tpages><orcidid>https://orcid.org/0000-0003-1879-4868</orcidid><orcidid>https://orcid.org/0000-0002-3916-8826</orcidid><orcidid>https://orcid.org/0000-0002-6557-6989</orcidid><orcidid>https://orcid.org/0000-0002-3528-1696</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0165-5876
ispartof International journal of pediatric otorhinolaryngology, 2022-08, Vol.159, p.111193-111193, Article 111193
issn 0165-5876
1872-8464
language eng
recordid cdi_proquest_miscellaneous_2679236491
source ScienceDirect Journals
subjects Laryngeal ultrasound
Pediatric otolaryngology
Thyroidectomy
Vocal cord mobility
Vocal cord paralysis
title Feasibility and accuracy of laryngeal ultrasound for the assessment of vocal cord mobility in children
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T13%3A55%3A48IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Feasibility%20and%20accuracy%20of%20laryngeal%20ultrasound%20for%20the%20assessment%20of%20vocal%20cord%20mobility%20in%20children&rft.jtitle=International%20journal%20of%20pediatric%20otorhinolaryngology&rft.au=Friesen,%20Tzyynong%20L.&rft.date=2022-08&rft.volume=159&rft.spage=111193&rft.epage=111193&rft.pages=111193-111193&rft.artnum=111193&rft.issn=0165-5876&rft.eissn=1872-8464&rft_id=info:doi/10.1016/j.ijporl.2022.111193&rft_dat=%3Cproquest_cross%3E2679236491%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c339t-aa3dc7c7365664297bc8a61c41206e5d0f0ada65ee7d6a731c4344214f2fe4293%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2679236491&rft_id=info:pmid/&rfr_iscdi=true