Loading…

Usefulness of simultaneous impulse oscillometry and spirometry with airway response to bronchodilator in the diagnosis of asthmatic cough

Objective: Some of the most common causes of chronic cough include cough variant asthma (CVA), bronchial asthma (BA), and asthma-COPD overlap (ACO). Although there is some overlap in the etiology of these diseases, it is clinically important to attempt an early differential diagnosis due to treatmen...

Full description

Saved in:
Bibliographic Details
Published in:The Journal of asthma 2023-04, Vol.60 (4), p.769-783
Main Authors: Taniuchi, Namiko, Hino, Mitsunori, Yoshikawa, Akiko, Miyanaga, Akihiko, Tanaka, Yosuke, Seike, Masahiro, Gemma, Akihiko
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Objective: Some of the most common causes of chronic cough include cough variant asthma (CVA), bronchial asthma (BA), and asthma-COPD overlap (ACO). Although there is some overlap in the etiology of these diseases, it is clinically important to attempt an early differential diagnosis due to treatment strategies and prognoses. Methods: Spirometry and impulse oscillometry (IOS) before and after bronchodilator inhalation were analyzed for clinically diagnosed CVA (cCVA, n = 203), BA (cBA, n = 222), and ACO (cACO, n = 61). Results: A significant difference in ΔFEV 1 was observed between cBA and cCVA (ΔFEV 1 improvement of 122.5 mL/5.4% and 65.7 mL/2.2%, respectively), but no difference was observed in ΔPEF, ΔV50, or ΔV25. Except for R20 (resistance at 20 Hz), significant differences between the three groups were observed in IOS. In IOS, cCVA and cBA showed comparable peripheral airway response to bronchodilator which was thought to be commensurate with changes in V50 and V25. cACO improved ΔFEV 1 improvement of 81.0 mL/6.2% and was distinguished by a downward respiratory system reactance (Xrs) waveform with a limited bronchodilator response. FEV 1 /FVC, %FEV 1 , and %V25 had relatively strong correlations with the three IOS parameters, X5 (reactance at 5 Hz), resonant frequency (Fres), and low-frequency reactance area (ALX), in the correlation between IOS and spirometers. Conclusion: Changes in IOS parameters were more sensitive in this study than changes in FEV 1 or the flow-volume curve. Considering the benefits and relevance of the two different tests, simultaneous IOS and spirometry testing were useful in the diagnosis of asthmatic cough.
ISSN:0277-0903
1532-4303
DOI:10.1080/02770903.2022.2094803