Loading…
Analytical Quality by Design-Based Robust RP-HPLC Method for Quantitative Estimation of Pregabalin and Etoricoxib in Fixed-Dose Combination Tablet Formulation
BACKGROUNDThe Central Drugs Standard Control Organization approved a bilayered, uncoated, fixed-dosage combination tablet formulation containing pregabalin (75 mg) and etoricoxib (60 mg) in November 2019 to control prolonged back pain with neuropathic components. OBJECTIVEThis research aims to creat...
Saved in:
Published in: | Journal of AOAC International 2022-10, Vol.105 (6), p.1536-1547 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | BACKGROUNDThe Central Drugs Standard Control Organization approved a bilayered, uncoated, fixed-dosage combination tablet formulation containing pregabalin (75 mg) and etoricoxib (60 mg) in November 2019 to control prolonged back pain with neuropathic components. OBJECTIVEThis research aims to create an analytical quality by design-assisted reversed phase (RP)-HPLC method for quantifying pregabalin and etoricoxib in tablet formulation. METHODSThe best chromatographic conditions were a Phenomenex C8 column (250 × 4.6 mm, 5.6 μm) and a mobile phase of 0.35% orthophosphoric acid -acetonitrile (1 + 1, by volume). A flow rate of 1 mL/min was used with a detection wavelength of 220 nm. RESULTSThe optimized reversed phase HPLC method was successfully validated by the International Conference on Hormonization guideline Q2(R1). Moreover, the percentage assay of pregabalin and etoricoxib tablet formulation was 99.05 and 100.02% w/w, respectively, using the validated RP-HPLC method. CONCLUSIONThe newly developed analytical quality by design-assisted RP-HPLC method has several advantages, including shortened analytical time (2.65 min and 7.45 min pregabalin and etoricoxib, respectively), efficient separation in terms of well-defined peaks, and a simple mobile phase combination. HIGHLIGHTSThe use of analytical quality by design principles and the design of the experiment tool allowed the detection of influential parameters critical for achieving the most favourable chromatographic conditions for accurately quantifying individual drugs using the RP-HPLC method. The compliance of the results with the ICH criteria validated the method. As a result, adopting the analytical quality by design methodology ensured the development of a more robust method that can generate consistent, dependable, and quality data throughout the process while also saving time. |
---|---|
ISSN: | 1060-3271 1944-7922 |
DOI: | 10.1093/jaoacint/qsac082 |