Loading…

Combined assessment by transcranial sonography and Sniffin’ Sticks test has a similar diagnostic accuracy compared to brain SPECT for Parkinson's disease diagnosis

AbstractObjectivesThis study aimed to investigate the accuracy of TCS combined with the Sniffin' sticks olfactory test (SST-16) for differentiation between idiopathic PD patients and healthy controls compared to that of 99mTc-TRODAT-1 SPECT (TRODAT). MethodsA cross-sectional study included PD p...

Full description

Saved in:
Bibliographic Details
Published in:Clinical neurology and neurosurgery 2022-09, Vol.220, p.107333-107333, Article 107333
Main Authors: Almeida, Kelson James, Bor-Seng-Shu, Edson, Pedroso, José Luiz, Felicio, Andre Carvalho, de-Lima-Oliveira, Marcelo, Barsottini, Orlando Graziani Povoas, de Carvalho Nogueira, Ricardo, Paschoal-Júnior, Fernando Mendes, Borges, Vanderci, Batista, Ilza Rosa, Teixeira, Manoel Jacobsen, Ferraz, Henrique Ballalai, Walter, Uwe
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:AbstractObjectivesThis study aimed to investigate the accuracy of TCS combined with the Sniffin' sticks olfactory test (SST-16) for differentiation between idiopathic PD patients and healthy controls compared to that of 99mTc-TRODAT-1 SPECT (TRODAT). MethodsA cross-sectional study included PD patients diagnosed in accordance with United Kingdom PD Society Brain Bank criteria and a control group of age and sex- matched healthy subjects. All patients were examined by a movement disorder specialist and underwent brain SPECT using TRODAT, TCS examination and SST-16 test. Receiver Operating Characteristic (ROC) curves were used to calculate cut-off points for TCS, striatal TRODAT binding potentials and SST-16. The area under the ROC curve determined the diagnostic accuracy of the method. ResultsTwenty patients with PD (13 males and 7 females) and nine healthy subjects were included. Median age of PD onset was 56.5 years with median disease duration of 5 years. A larger substantia nigra (SN) echogenic area was observed in the PD group (p=0.013). SN echogenic area cut-off point of 0.22 cm 2 was obtained from a ROC curve for PD diagnosis. Considering this cut-off point, TCS diagnostic accuracy was estimated at 79.2% for PD diagnosis. The cut-off value of 0.90 for striatal TRODAT binding was associated with 99% diagnostic accuracy for the diagnosis of PD. SST-16 values equal or less than 9 points showed an 85.8% diagnostic accuracy for PD diagnosis. Combination of both SST-16 and TCS improved the diagnostic accuracy to 95% for PD diagnosis. ConclusionCombined SST-16 and TCS assessment was indicated as accurate for distinguishing PD patients from healthy controls. The diagnostic accuracy of TCS combined with SST-16 for differentiation between idiopathic PD patients and healthy controls is similar to that of SPECT TRODAT.
ISSN:0303-8467
1872-6968
DOI:10.1016/j.clineuro.2022.107333