Loading…
Single Escherichia coli bacteria detection using a chemiluminescence digital microwell array chip
Rapid and sensitive Escherichia coli (E. coli) detection is important in determining environmental contamination, food contamination, as well as bacterial infection. Conventional methods based on bacterial culture suffer from long testing time (24 h), whereas novel nucleic acid-based and immunolabel...
Saved in:
Published in: | Biosensors & bioelectronics 2022-11, Vol.215, p.114594-114594, Article 114594 |
---|---|
Main Authors: | , , , , , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Rapid and sensitive Escherichia coli (E. coli) detection is important in determining environmental contamination, food contamination, as well as bacterial infection. Conventional methods based on bacterial culture suffer from long testing time (24 h), whereas novel nucleic acid-based and immunolabelling approaches are hindered by complicated operation, the need of complex and costly equipment, and the lack of differentiation of live and dead bacteria. Herein, we propose a chemiluminescence digital microwell array chip based on the hydrolysis of 6-Chloro-4-methylumbelliferyl-β-D-glucuronide by the β-D-glucuronidase in E. coli to achieve fast single bacterial fluorescence detection. Taking the advantage of the picoliter microwells, single bacteria are digitally encapsulated in these microwells, thus the accurate quantification of E. coli can be realized by counting the number of positive microwells. We also show that the chemiluminescence digital microwell array chip is not affected by the turbidity of the test samples as well as the temperature. Most importantly, our method can differentiate live and dead bacteria through bacterial proliferation and enzyme expression, which is confirmed by detecting E. coli after pH and chlorination treatment. By comparing with the standard method of plate counting, our method has comparable performance but significantly reduces the testing time from over 24 h–2 h and 4 h for qualitative and quantitative analysis, respectively. In addition, the microfluidic chip is portable and easy to operate without external pump, which is promising as a rapid and on-site platform for single E. coli analysis in water and food monitoring, as well as infection diagnosis. |
---|---|
ISSN: | 0956-5663 1873-4235 |
DOI: | 10.1016/j.bios.2022.114594 |