Personal dosimetry for positron emitters, and occupational exposures from clinical use of gallium-68
The current status and issues regarding positron dosimetry in nuclear medicine are summarized. The suitability of the United Kingdom Health Security Agency extremity and eye beta-gamma personal thermoluminescence dosemeters are then considered. Monte Carlo modelling is performed to determine their r...
Saved in:
Published in: | Journal of radiological protection 2022-09, Vol.42 (3), p.31511 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c345t-37bd528264a86eece27df49139c3852b8bc4c564bad1370a97747275a7dc3e473 |
---|---|
cites | cdi_FETCH-LOGICAL-c345t-37bd528264a86eece27df49139c3852b8bc4c564bad1370a97747275a7dc3e473 |
container_end_page | |
container_issue | 3 |
container_start_page | 31511 |
container_title | Journal of radiological protection |
container_volume | 42 |
creator | Eakins, J Hager, L O’Connor, U Cooke, J O’Reilly, G Walsh, C Willson, T |
description | The current status and issues regarding positron dosimetry in nuclear medicine are summarized. The suitability of the United Kingdom Health Security Agency extremity and eye beta-gamma personal thermoluminescence dosemeters are then considered. Monte Carlo modelling is performed to determine their responses and derive sets of calibration factors, along with
H
p
(0.07) and
H
p
(3) conversion coefficients, for carbon-11, nitrogen-13, oxygen-15, fluorine-18 and gallium-68 sources, which are commonly used in positron emission tomography (PET) computed tomography; data for these isotopes is assumed extrapolatable to other positron sources. It is found that the dosemeters are adequate for assessing exposures to PET radionuclides, even if their routine calibrations to caesium-137 were maintained. An idealized set of measurements representing gallium-68 exposure scenarios is then described, including reproducible mock-ups of individuals manipulating vials and syringes. Finally, a short case-study is presented that explores occupational doses during routine clinical use of gallium-68. The extremity dosemeter results demonstrated significant variations dependent upon the exposure conditions, with some seen to be comparatively large; whole-body and eye dose rates per activity were found to be lower. The importance of routine dose monitoring of workers is emphasized, with the need for a longer-termed follow-up study demonstrated. |
doi_str_mv | 10.1088/1361-6498/ac8885 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2701075566</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2701075566</sourcerecordid><originalsourceid>FETCH-LOGICAL-c345t-37bd528264a86eece27df49139c3852b8bc4c564bad1370a97747275a7dc3e473</originalsourceid><addsrcrecordid>eNp1kDtPwzAUhS0EEqWwM3qDoaF-2xlRxUuqBAPMluM4yFUSBzuR6L_HJYgJpqt79J0zfABcYnSDkVJrTAUuBCvV2lilFD8Ci9_oGCxQyUnBJBOn4CylHUJIUEoWoH5xMYXetLAOyXdujHvYhAiH_I0x9NB1fhwzs4Kmr2GwdhrM6L8b7jNTU3QJNjF00La-9zbnU3IwNPDdtK2fukKoc3DSmDa5i5-7BG_3d6-bx2L7_PC0ud0WljI-FlRWNSeKCGaUcM46IuuGlZiWlipOKlVZZrlglakxlciUUjJJJDeyttQxSZfget4dYviYXBp155N1bWt6F6akiUQYSc6FyCiaURtDStE1eoi-M3GvMdIHofpgTx_s6VlorlzNFR8GvQtTzA6S3sVBM6KpRhRzjPVQN5lc_UH-O_wFdAGE1A</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2701075566</pqid></control><display><type>article</type><title>Personal dosimetry for positron emitters, and occupational exposures from clinical use of gallium-68</title><source>Institute of Physics:Jisc Collections:IOP Publishing Read and Publish 2024-2025 (Reading List)</source><creator>Eakins, J ; Hager, L ; O’Connor, U ; Cooke, J ; O’Reilly, G ; Walsh, C ; Willson, T</creator><creatorcontrib>Eakins, J ; Hager, L ; O’Connor, U ; Cooke, J ; O’Reilly, G ; Walsh, C ; Willson, T</creatorcontrib><description>The current status and issues regarding positron dosimetry in nuclear medicine are summarized. The suitability of the United Kingdom Health Security Agency extremity and eye beta-gamma personal thermoluminescence dosemeters are then considered. Monte Carlo modelling is performed to determine their responses and derive sets of calibration factors, along with
H
p
(0.07) and
H
p
(3) conversion coefficients, for carbon-11, nitrogen-13, oxygen-15, fluorine-18 and gallium-68 sources, which are commonly used in positron emission tomography (PET) computed tomography; data for these isotopes is assumed extrapolatable to other positron sources. It is found that the dosemeters are adequate for assessing exposures to PET radionuclides, even if their routine calibrations to caesium-137 were maintained. An idealized set of measurements representing gallium-68 exposure scenarios is then described, including reproducible mock-ups of individuals manipulating vials and syringes. Finally, a short case-study is presented that explores occupational doses during routine clinical use of gallium-68. The extremity dosemeter results demonstrated significant variations dependent upon the exposure conditions, with some seen to be comparatively large; whole-body and eye dose rates per activity were found to be lower. The importance of routine dose monitoring of workers is emphasized, with the need for a longer-termed follow-up study demonstrated.</description><identifier>ISSN: 0952-4746</identifier><identifier>EISSN: 1361-6498</identifier><identifier>DOI: 10.1088/1361-6498/ac8885</identifier><identifier>CODEN: JRPREA</identifier><language>eng</language><publisher>IOP Publishing</publisher><subject>calibration ; medical dosimetry ; Monte Carlo ; occupational exposures ; personal dosimetry ; PET-CT ; positron</subject><ispartof>Journal of radiological protection, 2022-09, Vol.42 (3), p.31511</ispartof><rights>2022 Society for Radiological Protection. Published on behalf of SRP by IOP Publishing Limited. All rights reserved</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c345t-37bd528264a86eece27df49139c3852b8bc4c564bad1370a97747275a7dc3e473</citedby><cites>FETCH-LOGICAL-c345t-37bd528264a86eece27df49139c3852b8bc4c564bad1370a97747275a7dc3e473</cites><orcidid>0000-0003-3566-7801 ; 0000-0003-3970-7276 ; 0000-0001-8812-2499</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids></links><search><creatorcontrib>Eakins, J</creatorcontrib><creatorcontrib>Hager, L</creatorcontrib><creatorcontrib>O’Connor, U</creatorcontrib><creatorcontrib>Cooke, J</creatorcontrib><creatorcontrib>O’Reilly, G</creatorcontrib><creatorcontrib>Walsh, C</creatorcontrib><creatorcontrib>Willson, T</creatorcontrib><title>Personal dosimetry for positron emitters, and occupational exposures from clinical use of gallium-68</title><title>Journal of radiological protection</title><addtitle>JRP</addtitle><addtitle>J. Radiol. Prot</addtitle><description>The current status and issues regarding positron dosimetry in nuclear medicine are summarized. The suitability of the United Kingdom Health Security Agency extremity and eye beta-gamma personal thermoluminescence dosemeters are then considered. Monte Carlo modelling is performed to determine their responses and derive sets of calibration factors, along with
H
p
(0.07) and
H
p
(3) conversion coefficients, for carbon-11, nitrogen-13, oxygen-15, fluorine-18 and gallium-68 sources, which are commonly used in positron emission tomography (PET) computed tomography; data for these isotopes is assumed extrapolatable to other positron sources. It is found that the dosemeters are adequate for assessing exposures to PET radionuclides, even if their routine calibrations to caesium-137 were maintained. An idealized set of measurements representing gallium-68 exposure scenarios is then described, including reproducible mock-ups of individuals manipulating vials and syringes. Finally, a short case-study is presented that explores occupational doses during routine clinical use of gallium-68. The extremity dosemeter results demonstrated significant variations dependent upon the exposure conditions, with some seen to be comparatively large; whole-body and eye dose rates per activity were found to be lower. The importance of routine dose monitoring of workers is emphasized, with the need for a longer-termed follow-up study demonstrated.</description><subject>calibration</subject><subject>medical dosimetry</subject><subject>Monte Carlo</subject><subject>occupational exposures</subject><subject>personal dosimetry</subject><subject>PET-CT</subject><subject>positron</subject><issn>0952-4746</issn><issn>1361-6498</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNp1kDtPwzAUhS0EEqWwM3qDoaF-2xlRxUuqBAPMluM4yFUSBzuR6L_HJYgJpqt79J0zfABcYnSDkVJrTAUuBCvV2lilFD8Ci9_oGCxQyUnBJBOn4CylHUJIUEoWoH5xMYXetLAOyXdujHvYhAiH_I0x9NB1fhwzs4Kmr2GwdhrM6L8b7jNTU3QJNjF00La-9zbnU3IwNPDdtK2fukKoc3DSmDa5i5-7BG_3d6-bx2L7_PC0ud0WljI-FlRWNSeKCGaUcM46IuuGlZiWlipOKlVZZrlglakxlciUUjJJJDeyttQxSZfget4dYviYXBp155N1bWt6F6akiUQYSc6FyCiaURtDStE1eoi-M3GvMdIHofpgTx_s6VlorlzNFR8GvQtTzA6S3sVBM6KpRhRzjPVQN5lc_UH-O_wFdAGE1A</recordid><startdate>20220901</startdate><enddate>20220901</enddate><creator>Eakins, J</creator><creator>Hager, L</creator><creator>O’Connor, U</creator><creator>Cooke, J</creator><creator>O’Reilly, G</creator><creator>Walsh, C</creator><creator>Willson, T</creator><general>IOP Publishing</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-3566-7801</orcidid><orcidid>https://orcid.org/0000-0003-3970-7276</orcidid><orcidid>https://orcid.org/0000-0001-8812-2499</orcidid></search><sort><creationdate>20220901</creationdate><title>Personal dosimetry for positron emitters, and occupational exposures from clinical use of gallium-68</title><author>Eakins, J ; Hager, L ; O’Connor, U ; Cooke, J ; O’Reilly, G ; Walsh, C ; Willson, T</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c345t-37bd528264a86eece27df49139c3852b8bc4c564bad1370a97747275a7dc3e473</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>calibration</topic><topic>medical dosimetry</topic><topic>Monte Carlo</topic><topic>occupational exposures</topic><topic>personal dosimetry</topic><topic>PET-CT</topic><topic>positron</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Eakins, J</creatorcontrib><creatorcontrib>Hager, L</creatorcontrib><creatorcontrib>O’Connor, U</creatorcontrib><creatorcontrib>Cooke, J</creatorcontrib><creatorcontrib>O’Reilly, G</creatorcontrib><creatorcontrib>Walsh, C</creatorcontrib><creatorcontrib>Willson, T</creatorcontrib><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of radiological protection</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Eakins, J</au><au>Hager, L</au><au>O’Connor, U</au><au>Cooke, J</au><au>O’Reilly, G</au><au>Walsh, C</au><au>Willson, T</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Personal dosimetry for positron emitters, and occupational exposures from clinical use of gallium-68</atitle><jtitle>Journal of radiological protection</jtitle><stitle>JRP</stitle><addtitle>J. Radiol. Prot</addtitle><date>2022-09-01</date><risdate>2022</risdate><volume>42</volume><issue>3</issue><spage>31511</spage><pages>31511-</pages><issn>0952-4746</issn><eissn>1361-6498</eissn><coden>JRPREA</coden><abstract>The current status and issues regarding positron dosimetry in nuclear medicine are summarized. The suitability of the United Kingdom Health Security Agency extremity and eye beta-gamma personal thermoluminescence dosemeters are then considered. Monte Carlo modelling is performed to determine their responses and derive sets of calibration factors, along with
H
p
(0.07) and
H
p
(3) conversion coefficients, for carbon-11, nitrogen-13, oxygen-15, fluorine-18 and gallium-68 sources, which are commonly used in positron emission tomography (PET) computed tomography; data for these isotopes is assumed extrapolatable to other positron sources. It is found that the dosemeters are adequate for assessing exposures to PET radionuclides, even if their routine calibrations to caesium-137 were maintained. An idealized set of measurements representing gallium-68 exposure scenarios is then described, including reproducible mock-ups of individuals manipulating vials and syringes. Finally, a short case-study is presented that explores occupational doses during routine clinical use of gallium-68. The extremity dosemeter results demonstrated significant variations dependent upon the exposure conditions, with some seen to be comparatively large; whole-body and eye dose rates per activity were found to be lower. The importance of routine dose monitoring of workers is emphasized, with the need for a longer-termed follow-up study demonstrated.</abstract><pub>IOP Publishing</pub><doi>10.1088/1361-6498/ac8885</doi><tpages>20</tpages><orcidid>https://orcid.org/0000-0003-3566-7801</orcidid><orcidid>https://orcid.org/0000-0003-3970-7276</orcidid><orcidid>https://orcid.org/0000-0001-8812-2499</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0952-4746 |
ispartof | Journal of radiological protection, 2022-09, Vol.42 (3), p.31511 |
issn | 0952-4746 1361-6498 |
language | eng |
recordid | cdi_proquest_miscellaneous_2701075566 |
source | Institute of Physics:Jisc Collections:IOP Publishing Read and Publish 2024-2025 (Reading List) |
subjects | calibration medical dosimetry Monte Carlo occupational exposures personal dosimetry PET-CT positron |
title | Personal dosimetry for positron emitters, and occupational exposures from clinical use of gallium-68 |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T12%3A54%3A17IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Personal%20dosimetry%20for%20positron%20emitters,%20and%20occupational%20exposures%20from%20clinical%20use%20of%20gallium-68&rft.jtitle=Journal%20of%20radiological%20protection&rft.au=Eakins,%20J&rft.date=2022-09-01&rft.volume=42&rft.issue=3&rft.spage=31511&rft.pages=31511-&rft.issn=0952-4746&rft.eissn=1361-6498&rft.coden=JRPREA&rft_id=info:doi/10.1088/1361-6498/ac8885&rft_dat=%3Cproquest_cross%3E2701075566%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c345t-37bd528264a86eece27df49139c3852b8bc4c564bad1370a97747275a7dc3e473%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2701075566&rft_id=info:pmid/&rfr_iscdi=true |