Optimization of a SCALPEL ® exposure tool using a diffractive image quality technique

Determining and maintaining the best exposure parameters, such as dose, focus, or illumination uniformity, is a primary concern in operating a modern day stepper or scanner. A commonly adopted means of obtaining lithographic image quality information relies on accurately measuring CD values across a...

Full description

Saved in:
Bibliographic Details
Published in:Microelectronic engineering 1999, Vol.46 (1), p.239-242
Main Authors: Eichner, L., Blakey, M.I., Farrow, R.C., Liddle, J.A., Orphanos, P.A., Waskiewicz, W.K.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c315t-f841d6bc44b7e0b87f4e165f8549fabf243b3f8587923390dd45218d00af70933
container_end_page 242
container_issue 1
container_start_page 239
container_title Microelectronic engineering
container_volume 46
creator Eichner, L.
Blakey, M.I.
Farrow, R.C.
Liddle, J.A.
Orphanos, P.A.
Waskiewicz, W.K.
description Determining and maintaining the best exposure parameters, such as dose, focus, or illumination uniformity, is a primary concern in operating a modern day stepper or scanner. A commonly adopted means of obtaining lithographic image quality information relies on accurately measuring CD values across a wafer, die, or image field. Continually shrinking Linewidth have pushed this type of characterization into the realm of the CD-SEM; though greatly improved and automated in recent years, the accuracy required to reliably identify trends makes this a tedious and time consuming practice. We present here an alternative, flexible, and potentially rapid method for optimizing lithography conditions using a diffractive image quality (DIQ) technique, emphasizing its utility in a SCALPEL-based exposure system. A DIQ technique uses the fact that the maximum intensity of higher-order diffraction dispersions is a function of the (image) quality of the grating being illuminated so interrogation of gratings that have been exposed in resist can provide knowledge of how the aerial image quality can be varied for a given set of exposure conditions. We have evaluated grating diffraction efficiency using a probe beam (HeNe laser) introduced at a glancing angle. This arrangement has the advantage of looking at higher order intensity distributions while avoiding the zero order, as well as being fast since one is only collecting signal (eg. No feature recognition searches). Further, it enables the imaging optimization of a new system, such as SCALPEL, without tying up quantitative tools such as a CD-SEM. We have found that this metrology technique provides a quite sensitive and rapid identification of the best exposure conditions. Cross-correlation with a CD-SEM metrology tool has also been performed, in order to verify that the optimum imaging conditions identified through this DIQ technique correspond to the best CD conditions.
doi_str_mv 10.1016/S0167-9317(99)00071-4
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_27104506</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0167931799000714</els_id><sourcerecordid>27104506</sourcerecordid><originalsourceid>FETCH-LOGICAL-c315t-f841d6bc44b7e0b87f4e165f8549fabf243b3f8587923390dd45218d00af70933</originalsourceid><addsrcrecordid>eNqFkM1KLDEQhYNcwbnqIwhZXC66aE0m6U6yEhH_YEDBn21Ipysa6emMSVrUh_IhfDKjI7p0U0XBV3XqHIS2KNmlhDZ7l6WISjEqtpXaIYQIWvEVNKFSsKquG_kHTb6RNfQ3pXtSZk7kBN2cL7Kf-xeTfRhwcNjgy8OD2cXRDL-9YnhahDRGwDmEHo_JD7cF6Lxz0djsHwH7ubkF_DCa3udnnMHeDf5hhA206kyfYPOrr6Pr46Orw9Nqdn5yVu5XltE6V05y2jWt5bwVQFopHAfa1E7WXDnTuilnLSuTFGrKmCJdx-splR0hxgmiGFtH_5d3FzEU2ZT13CcLfW8GCGPSU0EJr0lTwHoJ2hhSiuD0Ipbf47OmRH-kqD9T1B8RaaX0Z4qal71_XwImWdMX34P16WdZSkq5LNj-EoNi9tFD1Ml6GCx0PoLNugv-F6F3UqOGSw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>27104506</pqid></control><display><type>article</type><title>Optimization of a SCALPEL ® exposure tool using a diffractive image quality technique</title><source>Elsevier</source><creator>Eichner, L. ; Blakey, M.I. ; Farrow, R.C. ; Liddle, J.A. ; Orphanos, P.A. ; Waskiewicz, W.K.</creator><creatorcontrib>Eichner, L. ; Blakey, M.I. ; Farrow, R.C. ; Liddle, J.A. ; Orphanos, P.A. ; Waskiewicz, W.K.</creatorcontrib><description>Determining and maintaining the best exposure parameters, such as dose, focus, or illumination uniformity, is a primary concern in operating a modern day stepper or scanner. A commonly adopted means of obtaining lithographic image quality information relies on accurately measuring CD values across a wafer, die, or image field. Continually shrinking Linewidth have pushed this type of characterization into the realm of the CD-SEM; though greatly improved and automated in recent years, the accuracy required to reliably identify trends makes this a tedious and time consuming practice. We present here an alternative, flexible, and potentially rapid method for optimizing lithography conditions using a diffractive image quality (DIQ) technique, emphasizing its utility in a SCALPEL-based exposure system. A DIQ technique uses the fact that the maximum intensity of higher-order diffraction dispersions is a function of the (image) quality of the grating being illuminated so interrogation of gratings that have been exposed in resist can provide knowledge of how the aerial image quality can be varied for a given set of exposure conditions. We have evaluated grating diffraction efficiency using a probe beam (HeNe laser) introduced at a glancing angle. This arrangement has the advantage of looking at higher order intensity distributions while avoiding the zero order, as well as being fast since one is only collecting signal (eg. No feature recognition searches). Further, it enables the imaging optimization of a new system, such as SCALPEL, without tying up quantitative tools such as a CD-SEM. We have found that this metrology technique provides a quite sensitive and rapid identification of the best exposure conditions. Cross-correlation with a CD-SEM metrology tool has also been performed, in order to verify that the optimum imaging conditions identified through this DIQ technique correspond to the best CD conditions.</description><identifier>ISSN: 0167-9317</identifier><identifier>EISSN: 1873-5568</identifier><identifier>DOI: 10.1016/S0167-9317(99)00071-4</identifier><identifier>CODEN: MIENEF</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Applied sciences ; Electronics ; Exact sciences and technology ; Microelectronic fabrication (materials and surfaces technology) ; Semiconductor electronics. Microelectronics. Optoelectronics. Solid state devices</subject><ispartof>Microelectronic engineering, 1999, Vol.46 (1), p.239-242</ispartof><rights>1999 Elsevier Science B.V. All rights reserved</rights><rights>1999 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c315t-f841d6bc44b7e0b87f4e165f8549fabf243b3f8587923390dd45218d00af70933</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>309,310,314,780,784,789,790,4024,4050,4051,23930,23931,25140,27923,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=1881148$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Eichner, L.</creatorcontrib><creatorcontrib>Blakey, M.I.</creatorcontrib><creatorcontrib>Farrow, R.C.</creatorcontrib><creatorcontrib>Liddle, J.A.</creatorcontrib><creatorcontrib>Orphanos, P.A.</creatorcontrib><creatorcontrib>Waskiewicz, W.K.</creatorcontrib><title>Optimization of a SCALPEL ® exposure tool using a diffractive image quality technique</title><title>Microelectronic engineering</title><description>Determining and maintaining the best exposure parameters, such as dose, focus, or illumination uniformity, is a primary concern in operating a modern day stepper or scanner. A commonly adopted means of obtaining lithographic image quality information relies on accurately measuring CD values across a wafer, die, or image field. Continually shrinking Linewidth have pushed this type of characterization into the realm of the CD-SEM; though greatly improved and automated in recent years, the accuracy required to reliably identify trends makes this a tedious and time consuming practice. We present here an alternative, flexible, and potentially rapid method for optimizing lithography conditions using a diffractive image quality (DIQ) technique, emphasizing its utility in a SCALPEL-based exposure system. A DIQ technique uses the fact that the maximum intensity of higher-order diffraction dispersions is a function of the (image) quality of the grating being illuminated so interrogation of gratings that have been exposed in resist can provide knowledge of how the aerial image quality can be varied for a given set of exposure conditions. We have evaluated grating diffraction efficiency using a probe beam (HeNe laser) introduced at a glancing angle. This arrangement has the advantage of looking at higher order intensity distributions while avoiding the zero order, as well as being fast since one is only collecting signal (eg. No feature recognition searches). Further, it enables the imaging optimization of a new system, such as SCALPEL, without tying up quantitative tools such as a CD-SEM. We have found that this metrology technique provides a quite sensitive and rapid identification of the best exposure conditions. Cross-correlation with a CD-SEM metrology tool has also been performed, in order to verify that the optimum imaging conditions identified through this DIQ technique correspond to the best CD conditions.</description><subject>Applied sciences</subject><subject>Electronics</subject><subject>Exact sciences and technology</subject><subject>Microelectronic fabrication (materials and surfaces technology)</subject><subject>Semiconductor electronics. Microelectronics. Optoelectronics. Solid state devices</subject><issn>0167-9317</issn><issn>1873-5568</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1999</creationdate><recordtype>article</recordtype><recordid>eNqFkM1KLDEQhYNcwbnqIwhZXC66aE0m6U6yEhH_YEDBn21Ipysa6emMSVrUh_IhfDKjI7p0U0XBV3XqHIS2KNmlhDZ7l6WISjEqtpXaIYQIWvEVNKFSsKquG_kHTb6RNfQ3pXtSZk7kBN2cL7Kf-xeTfRhwcNjgy8OD2cXRDL-9YnhahDRGwDmEHo_JD7cF6Lxz0djsHwH7ubkF_DCa3udnnMHeDf5hhA206kyfYPOrr6Pr46Orw9Nqdn5yVu5XltE6V05y2jWt5bwVQFopHAfa1E7WXDnTuilnLSuTFGrKmCJdx-splR0hxgmiGFtH_5d3FzEU2ZT13CcLfW8GCGPSU0EJr0lTwHoJ2hhSiuD0Ipbf47OmRH-kqD9T1B8RaaX0Z4qal71_XwImWdMX34P16WdZSkq5LNj-EoNi9tFD1Ml6GCx0PoLNugv-F6F3UqOGSw</recordid><startdate>1999</startdate><enddate>1999</enddate><creator>Eichner, L.</creator><creator>Blakey, M.I.</creator><creator>Farrow, R.C.</creator><creator>Liddle, J.A.</creator><creator>Orphanos, P.A.</creator><creator>Waskiewicz, W.K.</creator><general>Elsevier B.V</general><general>Elsevier Science</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>1999</creationdate><title>Optimization of a SCALPEL ® exposure tool using a diffractive image quality technique</title><author>Eichner, L. ; Blakey, M.I. ; Farrow, R.C. ; Liddle, J.A. ; Orphanos, P.A. ; Waskiewicz, W.K.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c315t-f841d6bc44b7e0b87f4e165f8549fabf243b3f8587923390dd45218d00af70933</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1999</creationdate><topic>Applied sciences</topic><topic>Electronics</topic><topic>Exact sciences and technology</topic><topic>Microelectronic fabrication (materials and surfaces technology)</topic><topic>Semiconductor electronics. Microelectronics. Optoelectronics. Solid state devices</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Eichner, L.</creatorcontrib><creatorcontrib>Blakey, M.I.</creatorcontrib><creatorcontrib>Farrow, R.C.</creatorcontrib><creatorcontrib>Liddle, J.A.</creatorcontrib><creatorcontrib>Orphanos, P.A.</creatorcontrib><creatorcontrib>Waskiewicz, W.K.</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Microelectronic engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Eichner, L.</au><au>Blakey, M.I.</au><au>Farrow, R.C.</au><au>Liddle, J.A.</au><au>Orphanos, P.A.</au><au>Waskiewicz, W.K.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Optimization of a SCALPEL ® exposure tool using a diffractive image quality technique</atitle><jtitle>Microelectronic engineering</jtitle><date>1999</date><risdate>1999</risdate><volume>46</volume><issue>1</issue><spage>239</spage><epage>242</epage><pages>239-242</pages><issn>0167-9317</issn><eissn>1873-5568</eissn><coden>MIENEF</coden><abstract>Determining and maintaining the best exposure parameters, such as dose, focus, or illumination uniformity, is a primary concern in operating a modern day stepper or scanner. A commonly adopted means of obtaining lithographic image quality information relies on accurately measuring CD values across a wafer, die, or image field. Continually shrinking Linewidth have pushed this type of characterization into the realm of the CD-SEM; though greatly improved and automated in recent years, the accuracy required to reliably identify trends makes this a tedious and time consuming practice. We present here an alternative, flexible, and potentially rapid method for optimizing lithography conditions using a diffractive image quality (DIQ) technique, emphasizing its utility in a SCALPEL-based exposure system. A DIQ technique uses the fact that the maximum intensity of higher-order diffraction dispersions is a function of the (image) quality of the grating being illuminated so interrogation of gratings that have been exposed in resist can provide knowledge of how the aerial image quality can be varied for a given set of exposure conditions. We have evaluated grating diffraction efficiency using a probe beam (HeNe laser) introduced at a glancing angle. This arrangement has the advantage of looking at higher order intensity distributions while avoiding the zero order, as well as being fast since one is only collecting signal (eg. No feature recognition searches). Further, it enables the imaging optimization of a new system, such as SCALPEL, without tying up quantitative tools such as a CD-SEM. We have found that this metrology technique provides a quite sensitive and rapid identification of the best exposure conditions. Cross-correlation with a CD-SEM metrology tool has also been performed, in order to verify that the optimum imaging conditions identified through this DIQ technique correspond to the best CD conditions.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><doi>10.1016/S0167-9317(99)00071-4</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0167-9317
ispartof Microelectronic engineering, 1999, Vol.46 (1), p.239-242
issn 0167-9317
1873-5568
language eng
recordid cdi_proquest_miscellaneous_27104506
source Elsevier
subjects Applied sciences
Electronics
Exact sciences and technology
Microelectronic fabrication (materials and surfaces technology)
Semiconductor electronics. Microelectronics. Optoelectronics. Solid state devices
title Optimization of a SCALPEL ® exposure tool using a diffractive image quality technique
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-24T15%3A16%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Optimization%20of%20a%20SCALPEL%20%C2%AE%20exposure%20tool%20using%20a%20diffractive%20image%20quality%20technique&rft.jtitle=Microelectronic%20engineering&rft.au=Eichner,%20L.&rft.date=1999&rft.volume=46&rft.issue=1&rft.spage=239&rft.epage=242&rft.pages=239-242&rft.issn=0167-9317&rft.eissn=1873-5568&rft.coden=MIENEF&rft_id=info:doi/10.1016/S0167-9317(99)00071-4&rft_dat=%3Cproquest_cross%3E27104506%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c315t-f841d6bc44b7e0b87f4e165f8549fabf243b3f8587923390dd45218d00af70933%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=27104506&rft_id=info:pmid/&rfr_iscdi=true