Loading…
Zirconia-veneered polyetherketoneketone frameworks of implant-supported complete arch fixed dental prostheses: A report on 5 patients
Metal frameworks have been used for implant-supported complete arch fixed dental prostheses (ISCFDPs) for maxillary or mandibular edentulous arches with a crown height space of more than 15 mm. However, technical difficulties in the casting, weight, and lack of passivity of the metal have led dentis...
Saved in:
Published in: | The Journal of prosthetic dentistry 2023-10, Vol.130 (4), p.419-433 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c345t-e5309171bd366290ec63fafc23854fadcd361f9930ceb5b9a811a5c0e3bf0e593 |
---|---|
cites | cdi_FETCH-LOGICAL-c345t-e5309171bd366290ec63fafc23854fadcd361f9930ceb5b9a811a5c0e3bf0e593 |
container_end_page | 433 |
container_issue | 4 |
container_start_page | 419 |
container_title | The Journal of prosthetic dentistry |
container_volume | 130 |
creator | Jung, Bock-Young Park, Won-Se Woo, Chang-Woo Jeong, Sol-Ah |
description | Metal frameworks have been used for implant-supported complete arch fixed dental prostheses (ISCFDPs) for maxillary or mandibular edentulous arches with a crown height space of more than 15 mm. However, technical difficulties in the casting, weight, and lack of passivity of the metal have led dentists and dental laboratory technicians to choose materials with different biomechanical properties, including polyetheretherketone (PEEK) and polyetherketoneketone (PEKK). This clinical report describes the design of ISCFDPs using PEKK frameworks, the number of cantilevers, the condition of the opposing dentition, and the incidence of complications, including zirconia crown or PEKK framework fracture, as well as the clinical outcomes of 5 patients observed prospectively over 8 to 65 months. No mechanical complications of PEKK-made ISCFDPs opposing removable prostheses occurred, regardless of the presence of cantilevers. The ISCFDPs that opposed natural dentition or a combination of the natural dentition and fixed prostheses showed different clinical outcomes depending on the length of cantilevers and the number and location of pontics. |
doi_str_mv | 10.1016/j.prosdent.2022.07.013 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2715438737</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0022391322004978</els_id><sourcerecordid>2715438737</sourcerecordid><originalsourceid>FETCH-LOGICAL-c345t-e5309171bd366290ec63fafc23854fadcd361f9930ceb5b9a811a5c0e3bf0e593</originalsourceid><addsrcrecordid>eNqFUEtOwzAUtBBIlMIVkJdsEp7jOh9WoIqfhMQGNmws13lWXdI42G6hB-DeOCqs2djSvJnRzBByziBnwMrLVT54F1rsY15AUeRQ5cD4AZkwaKqsrGfskEwgXTLeMH5MTkJYAUAtKjYh32_Wa9dblW2xR_TY0sF1O4xL9O8YXY_7lxqv1vjp_HugzlC7HjrVxyxshsH5mFTaJQgjUuX1khr7lbAxk-roGC_5BQxX9IZ6HBXU9VTQQUWbOOGUHBnVBTz7_afk9e72Zf6QPT3fP85vnjLNZyJmKDg0rGKLlpdl0QDqkhtldMFrMTOq1Qlnpmk4aFyIRaNqxpTQgHxhAEXDp-Ri75sifWwwRLm2QWOXuqDbBFlUTMx4XfEqUcs9Vaf0waORg7dr5XeSgRx3lyv5t7scd5dQybR7El7vhZiKbC16GXQqqbG1HnWUrbP_WfwA5UuT8A</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2715438737</pqid></control><display><type>article</type><title>Zirconia-veneered polyetherketoneketone frameworks of implant-supported complete arch fixed dental prostheses: A report on 5 patients</title><source>ScienceDirect Freedom Collection</source><creator>Jung, Bock-Young ; Park, Won-Se ; Woo, Chang-Woo ; Jeong, Sol-Ah</creator><creatorcontrib>Jung, Bock-Young ; Park, Won-Se ; Woo, Chang-Woo ; Jeong, Sol-Ah</creatorcontrib><description>Metal frameworks have been used for implant-supported complete arch fixed dental prostheses (ISCFDPs) for maxillary or mandibular edentulous arches with a crown height space of more than 15 mm. However, technical difficulties in the casting, weight, and lack of passivity of the metal have led dentists and dental laboratory technicians to choose materials with different biomechanical properties, including polyetheretherketone (PEEK) and polyetherketoneketone (PEKK). This clinical report describes the design of ISCFDPs using PEKK frameworks, the number of cantilevers, the condition of the opposing dentition, and the incidence of complications, including zirconia crown or PEKK framework fracture, as well as the clinical outcomes of 5 patients observed prospectively over 8 to 65 months. No mechanical complications of PEKK-made ISCFDPs opposing removable prostheses occurred, regardless of the presence of cantilevers. The ISCFDPs that opposed natural dentition or a combination of the natural dentition and fixed prostheses showed different clinical outcomes depending on the length of cantilevers and the number and location of pontics.</description><identifier>ISSN: 0022-3913</identifier><identifier>EISSN: 1097-6841</identifier><identifier>DOI: 10.1016/j.prosdent.2022.07.013</identifier><language>eng</language><publisher>Elsevier Inc</publisher><ispartof>The Journal of prosthetic dentistry, 2023-10, Vol.130 (4), p.419-433</ispartof><rights>2022 Editorial Council for The Journal of Prosthetic Dentistry</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c345t-e5309171bd366290ec63fafc23854fadcd361f9930ceb5b9a811a5c0e3bf0e593</citedby><cites>FETCH-LOGICAL-c345t-e5309171bd366290ec63fafc23854fadcd361f9930ceb5b9a811a5c0e3bf0e593</cites><orcidid>0000-0002-8186-2109</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Jung, Bock-Young</creatorcontrib><creatorcontrib>Park, Won-Se</creatorcontrib><creatorcontrib>Woo, Chang-Woo</creatorcontrib><creatorcontrib>Jeong, Sol-Ah</creatorcontrib><title>Zirconia-veneered polyetherketoneketone frameworks of implant-supported complete arch fixed dental prostheses: A report on 5 patients</title><title>The Journal of prosthetic dentistry</title><description>Metal frameworks have been used for implant-supported complete arch fixed dental prostheses (ISCFDPs) for maxillary or mandibular edentulous arches with a crown height space of more than 15 mm. However, technical difficulties in the casting, weight, and lack of passivity of the metal have led dentists and dental laboratory technicians to choose materials with different biomechanical properties, including polyetheretherketone (PEEK) and polyetherketoneketone (PEKK). This clinical report describes the design of ISCFDPs using PEKK frameworks, the number of cantilevers, the condition of the opposing dentition, and the incidence of complications, including zirconia crown or PEKK framework fracture, as well as the clinical outcomes of 5 patients observed prospectively over 8 to 65 months. No mechanical complications of PEKK-made ISCFDPs opposing removable prostheses occurred, regardless of the presence of cantilevers. The ISCFDPs that opposed natural dentition or a combination of the natural dentition and fixed prostheses showed different clinical outcomes depending on the length of cantilevers and the number and location of pontics.</description><issn>0022-3913</issn><issn>1097-6841</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNqFUEtOwzAUtBBIlMIVkJdsEp7jOh9WoIqfhMQGNmws13lWXdI42G6hB-DeOCqs2djSvJnRzBByziBnwMrLVT54F1rsY15AUeRQ5cD4AZkwaKqsrGfskEwgXTLeMH5MTkJYAUAtKjYh32_Wa9dblW2xR_TY0sF1O4xL9O8YXY_7lxqv1vjp_HugzlC7HjrVxyxshsH5mFTaJQgjUuX1khr7lbAxk-roGC_5BQxX9IZ6HBXU9VTQQUWbOOGUHBnVBTz7_afk9e72Zf6QPT3fP85vnjLNZyJmKDg0rGKLlpdl0QDqkhtldMFrMTOq1Qlnpmk4aFyIRaNqxpTQgHxhAEXDp-Ri75sifWwwRLm2QWOXuqDbBFlUTMx4XfEqUcs9Vaf0waORg7dr5XeSgRx3lyv5t7scd5dQybR7El7vhZiKbC16GXQqqbG1HnWUrbP_WfwA5UuT8A</recordid><startdate>202310</startdate><enddate>202310</enddate><creator>Jung, Bock-Young</creator><creator>Park, Won-Se</creator><creator>Woo, Chang-Woo</creator><creator>Jeong, Sol-Ah</creator><general>Elsevier Inc</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-8186-2109</orcidid></search><sort><creationdate>202310</creationdate><title>Zirconia-veneered polyetherketoneketone frameworks of implant-supported complete arch fixed dental prostheses: A report on 5 patients</title><author>Jung, Bock-Young ; Park, Won-Se ; Woo, Chang-Woo ; Jeong, Sol-Ah</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c345t-e5309171bd366290ec63fafc23854fadcd361f9930ceb5b9a811a5c0e3bf0e593</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Jung, Bock-Young</creatorcontrib><creatorcontrib>Park, Won-Se</creatorcontrib><creatorcontrib>Woo, Chang-Woo</creatorcontrib><creatorcontrib>Jeong, Sol-Ah</creatorcontrib><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of prosthetic dentistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Jung, Bock-Young</au><au>Park, Won-Se</au><au>Woo, Chang-Woo</au><au>Jeong, Sol-Ah</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Zirconia-veneered polyetherketoneketone frameworks of implant-supported complete arch fixed dental prostheses: A report on 5 patients</atitle><jtitle>The Journal of prosthetic dentistry</jtitle><date>2023-10</date><risdate>2023</risdate><volume>130</volume><issue>4</issue><spage>419</spage><epage>433</epage><pages>419-433</pages><issn>0022-3913</issn><eissn>1097-6841</eissn><abstract>Metal frameworks have been used for implant-supported complete arch fixed dental prostheses (ISCFDPs) for maxillary or mandibular edentulous arches with a crown height space of more than 15 mm. However, technical difficulties in the casting, weight, and lack of passivity of the metal have led dentists and dental laboratory technicians to choose materials with different biomechanical properties, including polyetheretherketone (PEEK) and polyetherketoneketone (PEKK). This clinical report describes the design of ISCFDPs using PEKK frameworks, the number of cantilevers, the condition of the opposing dentition, and the incidence of complications, including zirconia crown or PEKK framework fracture, as well as the clinical outcomes of 5 patients observed prospectively over 8 to 65 months. No mechanical complications of PEKK-made ISCFDPs opposing removable prostheses occurred, regardless of the presence of cantilevers. The ISCFDPs that opposed natural dentition or a combination of the natural dentition and fixed prostheses showed different clinical outcomes depending on the length of cantilevers and the number and location of pontics.</abstract><pub>Elsevier Inc</pub><doi>10.1016/j.prosdent.2022.07.013</doi><tpages>15</tpages><orcidid>https://orcid.org/0000-0002-8186-2109</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0022-3913 |
ispartof | The Journal of prosthetic dentistry, 2023-10, Vol.130 (4), p.419-433 |
issn | 0022-3913 1097-6841 |
language | eng |
recordid | cdi_proquest_miscellaneous_2715438737 |
source | ScienceDirect Freedom Collection |
title | Zirconia-veneered polyetherketoneketone frameworks of implant-supported complete arch fixed dental prostheses: A report on 5 patients |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T12%3A50%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Zirconia-veneered%20polyetherketoneketone%20frameworks%20of%20implant-supported%20complete%20arch%20fixed%20dental%20prostheses:%20A%20report%20on%205%20patients&rft.jtitle=The%20Journal%20of%20prosthetic%20dentistry&rft.au=Jung,%20Bock-Young&rft.date=2023-10&rft.volume=130&rft.issue=4&rft.spage=419&rft.epage=433&rft.pages=419-433&rft.issn=0022-3913&rft.eissn=1097-6841&rft_id=info:doi/10.1016/j.prosdent.2022.07.013&rft_dat=%3Cproquest_cross%3E2715438737%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c345t-e5309171bd366290ec63fafc23854fadcd361f9930ceb5b9a811a5c0e3bf0e593%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2715438737&rft_id=info:pmid/&rfr_iscdi=true |