Thermal diffusivity measurement of black and metallic graphite paint coatings
The suitability of a single-access approach involving a pulsed laser technique for non-contact and non-destructive measurement of thermal diffusivity is further examined. It was used to measure the thermal diffusivity of black and metallic graphite paint coatings. The values obtained in the present...
Saved in:
Published in: | Measurement science & technology 1999-01, Vol.10 (1), p.7-10 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The suitability of a single-access approach involving a pulsed laser technique for non-contact and non-destructive measurement of thermal diffusivity is further examined. It was used to measure the thermal diffusivity of black and metallic graphite paint coatings. The values obtained in the present work are (2.46 plus /minus 0.08) mult 10 exp -7 and (2.04 plus/minus 0.06) mult 10 exp -7 m exp 2 s exp -1 for black and metallic graphite paint coatings respectively. All measurements were performed at room temperature. (Example materials: mild steel and a glass fiber-phenolic resin composite.) |
---|---|
ISSN: | 0957-0233 1361-6501 |
DOI: | 10.1088/0957-0233/10/1/005 |