Loading…
Two‐piece zirconia implants in the posterior mandible and maxilla: A cohort study with a follow‐up period of 9 years
Objectives Long‐term follow‐up observations of zirconia implants are rare. This study aimed at evaluating the clinical performance of two‐piece zirconia implants in the posterior jaws over 9 years. Materials and Methods Sixty partially edentulous patients were treated with two‐piece zirconia implant...
Saved in:
Published in: | Clinical oral implants research 2022-12, Vol.33 (12), p.1233-1244 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Objectives
Long‐term follow‐up observations of zirconia implants are rare. This study aimed at evaluating the clinical performance of two‐piece zirconia implants in the posterior jaws over 9 years.
Materials and Methods
Sixty partially edentulous patients were treated with two‐piece zirconia implants. In eight no primary stability could be achieved. Fifty‐two patients received the final restoration (i.e., cemented fibreglass abutments and all‐ceramic crowns). After 2 years, 2 implants failed and 4 dropouts were recorded. The remaining 46 patients with one target implant each were recalled at 9 years. Besides implant survival, clinical parameters at the implant level (plaque index–PI, bleeding on probing–BOP, probing depth–PD, mucosal recession–MR) were recorded and compared with previously collected data. Mechanical and technical complications were assessed.
Results
Thirty patients responded. The mean observation period was of 111.1 ± 2.2 months. One implant was lost. Data recorded from the remaining 29 implants were analysed. PI values increased overtime. Mean BOP and PD remained unchanged during follow‐up. No additional cases of peri‐implantitis were recorded over the 10 diagnosed during the first 2 years of follow‐up. No significant changes in mean MR values were detected over time, with 65% of the all included implants exhibiting no recession at 9 years and all the others, but one, a maximum MR of 1 mm. Three technical and 6 mechanical complications occurred in 7 patients between 2‐ and 9‐years (6.9% and 20.7%, respectively, at patient level).
Conclusion
Within the limitations of the present study, a high survival rate was registered. Albeit frequent mechanical and technical complications, two‐piece zirconia implants could represent a valid solution for the replacement of single teeth in the posterior jaws. |
---|---|
ISSN: | 0905-7161 1600-0501 |
DOI: | 10.1111/clr.14005 |