Loading…
Evaluation of optical parameters for a microminiature Rb vapor cell in a dual-beam SERF magnetometer
In the spin-exchange relaxation-free (SERF) magnetometer of a perpendicular pump-probe configuration, the pump and probe beam characteristics significantly affect the performance. In this paper, an efficient evaluation of optical parameters to improve the sensitivity of a miniature magnetometer has...
Saved in:
Published in: | Optics express 2022-06, Vol.30 (13), p.23587-23599 |
---|---|
Main Authors: | , , , , , , , |
Format: | Article |
Language: | English |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c297t-1397dc7901b6eb0e4accb2c3750252899ba4ab3a1b9435b82fc69ac23ad6e8db3 |
---|---|
cites | cdi_FETCH-LOGICAL-c297t-1397dc7901b6eb0e4accb2c3750252899ba4ab3a1b9435b82fc69ac23ad6e8db3 |
container_end_page | 23599 |
container_issue | 13 |
container_start_page | 23587 |
container_title | Optics express |
container_volume | 30 |
creator | Wang, Yaxiang Shi, Tao Zhou, Weiyong Tang, JunJian Zhou, BinQuan Jin, Ge Han, Bangcheng Zou, Sheng |
description | In the spin-exchange relaxation-free (SERF) magnetometer of a perpendicular pump-probe configuration, the pump and probe beam characteristics significantly affect the performance. In this paper, an efficient evaluation of optical parameters to improve the sensitivity of a miniature magnetometer has been presented. We have determined the pump light’s optimal intensity and wavelength through theoretical analysis and the zero-field resonance experiments. Chirp signals are applied to measure the optical rotations at different probe intensities and frequencies. Through theoretical and experimental analysis of noise source characterization under different beam intensities and wavelengths, we demonstrate that dual-beam magnetometer performance is mainly limited by photon shot noise. Based on the optimum pump and probe beam parameters, we demonstrate magnetic field sensitivity of 6.3 fT/ Hz in an 87 Rb vapor cell filled with nitrogen gas, with an active measurement volume of 3 × 3 × 3 mm 3 . |
doi_str_mv | 10.1364/OE.458827 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2724583779</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2724583779</sourcerecordid><originalsourceid>FETCH-LOGICAL-c297t-1397dc7901b6eb0e4accb2c3750252899ba4ab3a1b9435b82fc69ac23ad6e8db3</originalsourceid><addsrcrecordid>eNpNkE1LxDAQhoMouK4e_Ac56qFrvto0R1m6KiwsrHoukzSVSNvUJF3w39t1PXiaF-bhZeZB6JaSFeWFeNhVK5GXJZNnaEGJEpkgpTz_ly_RVYyfhFAhlVygpjpAN0FyfsC-xX5MzkCHRwjQ22RDxK0PGHDvTPC9GxykKVi81_gA47wxtuuwG2aimaDLtIUev1b7De7hY7DJ_5Zco4sWumhv_uYSvW-qt_Vztt09vawft5lhSqaMciUbIxWhurCaWAHGaGa4zAnLWamUBgGaA9VK8FyXrDWFAsM4NIUtG82X6O7UOwb_NdmY6t7F44UwWD_Fmkk2y-FSqhm9P6HzWzEG29ZjcD2E75qS-miy3lX1yST_AdzfZok</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2724583779</pqid></control><display><type>article</type><title>Evaluation of optical parameters for a microminiature Rb vapor cell in a dual-beam SERF magnetometer</title><source>EZB Electronic Journals Library</source><creator>Wang, Yaxiang ; Shi, Tao ; Zhou, Weiyong ; Tang, JunJian ; Zhou, BinQuan ; Jin, Ge ; Han, Bangcheng ; Zou, Sheng</creator><creatorcontrib>Wang, Yaxiang ; Shi, Tao ; Zhou, Weiyong ; Tang, JunJian ; Zhou, BinQuan ; Jin, Ge ; Han, Bangcheng ; Zou, Sheng</creatorcontrib><description>In the spin-exchange relaxation-free (SERF) magnetometer of a perpendicular pump-probe configuration, the pump and probe beam characteristics significantly affect the performance. In this paper, an efficient evaluation of optical parameters to improve the sensitivity of a miniature magnetometer has been presented. We have determined the pump light’s optimal intensity and wavelength through theoretical analysis and the zero-field resonance experiments. Chirp signals are applied to measure the optical rotations at different probe intensities and frequencies. Through theoretical and experimental analysis of noise source characterization under different beam intensities and wavelengths, we demonstrate that dual-beam magnetometer performance is mainly limited by photon shot noise. Based on the optimum pump and probe beam parameters, we demonstrate magnetic field sensitivity of 6.3 fT/ Hz in an 87 Rb vapor cell filled with nitrogen gas, with an active measurement volume of 3 × 3 × 3 mm 3 .</description><identifier>ISSN: 1094-4087</identifier><identifier>EISSN: 1094-4087</identifier><identifier>DOI: 10.1364/OE.458827</identifier><language>eng</language><ispartof>Optics express, 2022-06, Vol.30 (13), p.23587-23599</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c297t-1397dc7901b6eb0e4accb2c3750252899ba4ab3a1b9435b82fc69ac23ad6e8db3</citedby><cites>FETCH-LOGICAL-c297t-1397dc7901b6eb0e4accb2c3750252899ba4ab3a1b9435b82fc69ac23ad6e8db3</cites><orcidid>0000-0002-5739-7104 ; 0000-0001-6919-7129 ; 0000-0001-9763-6723</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Wang, Yaxiang</creatorcontrib><creatorcontrib>Shi, Tao</creatorcontrib><creatorcontrib>Zhou, Weiyong</creatorcontrib><creatorcontrib>Tang, JunJian</creatorcontrib><creatorcontrib>Zhou, BinQuan</creatorcontrib><creatorcontrib>Jin, Ge</creatorcontrib><creatorcontrib>Han, Bangcheng</creatorcontrib><creatorcontrib>Zou, Sheng</creatorcontrib><title>Evaluation of optical parameters for a microminiature Rb vapor cell in a dual-beam SERF magnetometer</title><title>Optics express</title><description>In the spin-exchange relaxation-free (SERF) magnetometer of a perpendicular pump-probe configuration, the pump and probe beam characteristics significantly affect the performance. In this paper, an efficient evaluation of optical parameters to improve the sensitivity of a miniature magnetometer has been presented. We have determined the pump light’s optimal intensity and wavelength through theoretical analysis and the zero-field resonance experiments. Chirp signals are applied to measure the optical rotations at different probe intensities and frequencies. Through theoretical and experimental analysis of noise source characterization under different beam intensities and wavelengths, we demonstrate that dual-beam magnetometer performance is mainly limited by photon shot noise. Based on the optimum pump and probe beam parameters, we demonstrate magnetic field sensitivity of 6.3 fT/ Hz in an 87 Rb vapor cell filled with nitrogen gas, with an active measurement volume of 3 × 3 × 3 mm 3 .</description><issn>1094-4087</issn><issn>1094-4087</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNpNkE1LxDAQhoMouK4e_Ac56qFrvto0R1m6KiwsrHoukzSVSNvUJF3w39t1PXiaF-bhZeZB6JaSFeWFeNhVK5GXJZNnaEGJEpkgpTz_ly_RVYyfhFAhlVygpjpAN0FyfsC-xX5MzkCHRwjQ22RDxK0PGHDvTPC9GxykKVi81_gA47wxtuuwG2aimaDLtIUev1b7De7hY7DJ_5Zco4sWumhv_uYSvW-qt_Vztt09vawft5lhSqaMciUbIxWhurCaWAHGaGa4zAnLWamUBgGaA9VK8FyXrDWFAsM4NIUtG82X6O7UOwb_NdmY6t7F44UwWD_Fmkk2y-FSqhm9P6HzWzEG29ZjcD2E75qS-miy3lX1yST_AdzfZok</recordid><startdate>20220620</startdate><enddate>20220620</enddate><creator>Wang, Yaxiang</creator><creator>Shi, Tao</creator><creator>Zhou, Weiyong</creator><creator>Tang, JunJian</creator><creator>Zhou, BinQuan</creator><creator>Jin, Ge</creator><creator>Han, Bangcheng</creator><creator>Zou, Sheng</creator><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-5739-7104</orcidid><orcidid>https://orcid.org/0000-0001-6919-7129</orcidid><orcidid>https://orcid.org/0000-0001-9763-6723</orcidid></search><sort><creationdate>20220620</creationdate><title>Evaluation of optical parameters for a microminiature Rb vapor cell in a dual-beam SERF magnetometer</title><author>Wang, Yaxiang ; Shi, Tao ; Zhou, Weiyong ; Tang, JunJian ; Zhou, BinQuan ; Jin, Ge ; Han, Bangcheng ; Zou, Sheng</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c297t-1397dc7901b6eb0e4accb2c3750252899ba4ab3a1b9435b82fc69ac23ad6e8db3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wang, Yaxiang</creatorcontrib><creatorcontrib>Shi, Tao</creatorcontrib><creatorcontrib>Zhou, Weiyong</creatorcontrib><creatorcontrib>Tang, JunJian</creatorcontrib><creatorcontrib>Zhou, BinQuan</creatorcontrib><creatorcontrib>Jin, Ge</creatorcontrib><creatorcontrib>Han, Bangcheng</creatorcontrib><creatorcontrib>Zou, Sheng</creatorcontrib><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Optics express</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wang, Yaxiang</au><au>Shi, Tao</au><au>Zhou, Weiyong</au><au>Tang, JunJian</au><au>Zhou, BinQuan</au><au>Jin, Ge</au><au>Han, Bangcheng</au><au>Zou, Sheng</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of optical parameters for a microminiature Rb vapor cell in a dual-beam SERF magnetometer</atitle><jtitle>Optics express</jtitle><date>2022-06-20</date><risdate>2022</risdate><volume>30</volume><issue>13</issue><spage>23587</spage><epage>23599</epage><pages>23587-23599</pages><issn>1094-4087</issn><eissn>1094-4087</eissn><abstract>In the spin-exchange relaxation-free (SERF) magnetometer of a perpendicular pump-probe configuration, the pump and probe beam characteristics significantly affect the performance. In this paper, an efficient evaluation of optical parameters to improve the sensitivity of a miniature magnetometer has been presented. We have determined the pump light’s optimal intensity and wavelength through theoretical analysis and the zero-field resonance experiments. Chirp signals are applied to measure the optical rotations at different probe intensities and frequencies. Through theoretical and experimental analysis of noise source characterization under different beam intensities and wavelengths, we demonstrate that dual-beam magnetometer performance is mainly limited by photon shot noise. Based on the optimum pump and probe beam parameters, we demonstrate magnetic field sensitivity of 6.3 fT/ Hz in an 87 Rb vapor cell filled with nitrogen gas, with an active measurement volume of 3 × 3 × 3 mm 3 .</abstract><doi>10.1364/OE.458827</doi><tpages>13</tpages><orcidid>https://orcid.org/0000-0002-5739-7104</orcidid><orcidid>https://orcid.org/0000-0001-6919-7129</orcidid><orcidid>https://orcid.org/0000-0001-9763-6723</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1094-4087 |
ispartof | Optics express, 2022-06, Vol.30 (13), p.23587-23599 |
issn | 1094-4087 1094-4087 |
language | eng |
recordid | cdi_proquest_miscellaneous_2724583779 |
source | EZB Electronic Journals Library |
title | Evaluation of optical parameters for a microminiature Rb vapor cell in a dual-beam SERF magnetometer |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T00%3A07%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20optical%20parameters%20for%20a%20microminiature%20Rb%20vapor%20cell%20in%20a%20dual-beam%20SERF%20magnetometer&rft.jtitle=Optics%20express&rft.au=Wang,%20Yaxiang&rft.date=2022-06-20&rft.volume=30&rft.issue=13&rft.spage=23587&rft.epage=23599&rft.pages=23587-23599&rft.issn=1094-4087&rft.eissn=1094-4087&rft_id=info:doi/10.1364/OE.458827&rft_dat=%3Cproquest_cross%3E2724583779%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c297t-1397dc7901b6eb0e4accb2c3750252899ba4ab3a1b9435b82fc69ac23ad6e8db3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2724583779&rft_id=info:pmid/&rfr_iscdi=true |