Loading…

Evaluation of optical parameters for a microminiature Rb vapor cell in a dual-beam SERF magnetometer

In the spin-exchange relaxation-free (SERF) magnetometer of a perpendicular pump-probe configuration, the pump and probe beam characteristics significantly affect the performance. In this paper, an efficient evaluation of optical parameters to improve the sensitivity of a miniature magnetometer has...

Full description

Saved in:
Bibliographic Details
Published in:Optics express 2022-06, Vol.30 (13), p.23587-23599
Main Authors: Wang, Yaxiang, Shi, Tao, Zhou, Weiyong, Tang, JunJian, Zhou, BinQuan, Jin, Ge, Han, Bangcheng, Zou, Sheng
Format: Article
Language:English
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c297t-1397dc7901b6eb0e4accb2c3750252899ba4ab3a1b9435b82fc69ac23ad6e8db3
cites cdi_FETCH-LOGICAL-c297t-1397dc7901b6eb0e4accb2c3750252899ba4ab3a1b9435b82fc69ac23ad6e8db3
container_end_page 23599
container_issue 13
container_start_page 23587
container_title Optics express
container_volume 30
creator Wang, Yaxiang
Shi, Tao
Zhou, Weiyong
Tang, JunJian
Zhou, BinQuan
Jin, Ge
Han, Bangcheng
Zou, Sheng
description In the spin-exchange relaxation-free (SERF) magnetometer of a perpendicular pump-probe configuration, the pump and probe beam characteristics significantly affect the performance. In this paper, an efficient evaluation of optical parameters to improve the sensitivity of a miniature magnetometer has been presented. We have determined the pump light’s optimal intensity and wavelength through theoretical analysis and the zero-field resonance experiments. Chirp signals are applied to measure the optical rotations at different probe intensities and frequencies. Through theoretical and experimental analysis of noise source characterization under different beam intensities and wavelengths, we demonstrate that dual-beam magnetometer performance is mainly limited by photon shot noise. Based on the optimum pump and probe beam parameters, we demonstrate magnetic field sensitivity of 6.3 fT/ Hz in an 87 Rb vapor cell filled with nitrogen gas, with an active measurement volume of 3 × 3 × 3 mm 3 .
doi_str_mv 10.1364/OE.458827
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2724583779</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2724583779</sourcerecordid><originalsourceid>FETCH-LOGICAL-c297t-1397dc7901b6eb0e4accb2c3750252899ba4ab3a1b9435b82fc69ac23ad6e8db3</originalsourceid><addsrcrecordid>eNpNkE1LxDAQhoMouK4e_Ac56qFrvto0R1m6KiwsrHoukzSVSNvUJF3w39t1PXiaF-bhZeZB6JaSFeWFeNhVK5GXJZNnaEGJEpkgpTz_ly_RVYyfhFAhlVygpjpAN0FyfsC-xX5MzkCHRwjQ22RDxK0PGHDvTPC9GxykKVi81_gA47wxtuuwG2aimaDLtIUev1b7De7hY7DJ_5Zco4sWumhv_uYSvW-qt_Vztt09vawft5lhSqaMciUbIxWhurCaWAHGaGa4zAnLWamUBgGaA9VK8FyXrDWFAsM4NIUtG82X6O7UOwb_NdmY6t7F44UwWD_Fmkk2y-FSqhm9P6HzWzEG29ZjcD2E75qS-miy3lX1yST_AdzfZok</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2724583779</pqid></control><display><type>article</type><title>Evaluation of optical parameters for a microminiature Rb vapor cell in a dual-beam SERF magnetometer</title><source>EZB Electronic Journals Library</source><creator>Wang, Yaxiang ; Shi, Tao ; Zhou, Weiyong ; Tang, JunJian ; Zhou, BinQuan ; Jin, Ge ; Han, Bangcheng ; Zou, Sheng</creator><creatorcontrib>Wang, Yaxiang ; Shi, Tao ; Zhou, Weiyong ; Tang, JunJian ; Zhou, BinQuan ; Jin, Ge ; Han, Bangcheng ; Zou, Sheng</creatorcontrib><description>In the spin-exchange relaxation-free (SERF) magnetometer of a perpendicular pump-probe configuration, the pump and probe beam characteristics significantly affect the performance. In this paper, an efficient evaluation of optical parameters to improve the sensitivity of a miniature magnetometer has been presented. We have determined the pump light’s optimal intensity and wavelength through theoretical analysis and the zero-field resonance experiments. Chirp signals are applied to measure the optical rotations at different probe intensities and frequencies. Through theoretical and experimental analysis of noise source characterization under different beam intensities and wavelengths, we demonstrate that dual-beam magnetometer performance is mainly limited by photon shot noise. Based on the optimum pump and probe beam parameters, we demonstrate magnetic field sensitivity of 6.3 fT/ Hz in an 87 Rb vapor cell filled with nitrogen gas, with an active measurement volume of 3 × 3 × 3 mm 3 .</description><identifier>ISSN: 1094-4087</identifier><identifier>EISSN: 1094-4087</identifier><identifier>DOI: 10.1364/OE.458827</identifier><language>eng</language><ispartof>Optics express, 2022-06, Vol.30 (13), p.23587-23599</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c297t-1397dc7901b6eb0e4accb2c3750252899ba4ab3a1b9435b82fc69ac23ad6e8db3</citedby><cites>FETCH-LOGICAL-c297t-1397dc7901b6eb0e4accb2c3750252899ba4ab3a1b9435b82fc69ac23ad6e8db3</cites><orcidid>0000-0002-5739-7104 ; 0000-0001-6919-7129 ; 0000-0001-9763-6723</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Wang, Yaxiang</creatorcontrib><creatorcontrib>Shi, Tao</creatorcontrib><creatorcontrib>Zhou, Weiyong</creatorcontrib><creatorcontrib>Tang, JunJian</creatorcontrib><creatorcontrib>Zhou, BinQuan</creatorcontrib><creatorcontrib>Jin, Ge</creatorcontrib><creatorcontrib>Han, Bangcheng</creatorcontrib><creatorcontrib>Zou, Sheng</creatorcontrib><title>Evaluation of optical parameters for a microminiature Rb vapor cell in a dual-beam SERF magnetometer</title><title>Optics express</title><description>In the spin-exchange relaxation-free (SERF) magnetometer of a perpendicular pump-probe configuration, the pump and probe beam characteristics significantly affect the performance. In this paper, an efficient evaluation of optical parameters to improve the sensitivity of a miniature magnetometer has been presented. We have determined the pump light’s optimal intensity and wavelength through theoretical analysis and the zero-field resonance experiments. Chirp signals are applied to measure the optical rotations at different probe intensities and frequencies. Through theoretical and experimental analysis of noise source characterization under different beam intensities and wavelengths, we demonstrate that dual-beam magnetometer performance is mainly limited by photon shot noise. Based on the optimum pump and probe beam parameters, we demonstrate magnetic field sensitivity of 6.3 fT/ Hz in an 87 Rb vapor cell filled with nitrogen gas, with an active measurement volume of 3 × 3 × 3 mm 3 .</description><issn>1094-4087</issn><issn>1094-4087</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNpNkE1LxDAQhoMouK4e_Ac56qFrvto0R1m6KiwsrHoukzSVSNvUJF3w39t1PXiaF-bhZeZB6JaSFeWFeNhVK5GXJZNnaEGJEpkgpTz_ly_RVYyfhFAhlVygpjpAN0FyfsC-xX5MzkCHRwjQ22RDxK0PGHDvTPC9GxykKVi81_gA47wxtuuwG2aimaDLtIUev1b7De7hY7DJ_5Zco4sWumhv_uYSvW-qt_Vztt09vawft5lhSqaMciUbIxWhurCaWAHGaGa4zAnLWamUBgGaA9VK8FyXrDWFAsM4NIUtG82X6O7UOwb_NdmY6t7F44UwWD_Fmkk2y-FSqhm9P6HzWzEG29ZjcD2E75qS-miy3lX1yST_AdzfZok</recordid><startdate>20220620</startdate><enddate>20220620</enddate><creator>Wang, Yaxiang</creator><creator>Shi, Tao</creator><creator>Zhou, Weiyong</creator><creator>Tang, JunJian</creator><creator>Zhou, BinQuan</creator><creator>Jin, Ge</creator><creator>Han, Bangcheng</creator><creator>Zou, Sheng</creator><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-5739-7104</orcidid><orcidid>https://orcid.org/0000-0001-6919-7129</orcidid><orcidid>https://orcid.org/0000-0001-9763-6723</orcidid></search><sort><creationdate>20220620</creationdate><title>Evaluation of optical parameters for a microminiature Rb vapor cell in a dual-beam SERF magnetometer</title><author>Wang, Yaxiang ; Shi, Tao ; Zhou, Weiyong ; Tang, JunJian ; Zhou, BinQuan ; Jin, Ge ; Han, Bangcheng ; Zou, Sheng</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c297t-1397dc7901b6eb0e4accb2c3750252899ba4ab3a1b9435b82fc69ac23ad6e8db3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wang, Yaxiang</creatorcontrib><creatorcontrib>Shi, Tao</creatorcontrib><creatorcontrib>Zhou, Weiyong</creatorcontrib><creatorcontrib>Tang, JunJian</creatorcontrib><creatorcontrib>Zhou, BinQuan</creatorcontrib><creatorcontrib>Jin, Ge</creatorcontrib><creatorcontrib>Han, Bangcheng</creatorcontrib><creatorcontrib>Zou, Sheng</creatorcontrib><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Optics express</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wang, Yaxiang</au><au>Shi, Tao</au><au>Zhou, Weiyong</au><au>Tang, JunJian</au><au>Zhou, BinQuan</au><au>Jin, Ge</au><au>Han, Bangcheng</au><au>Zou, Sheng</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of optical parameters for a microminiature Rb vapor cell in a dual-beam SERF magnetometer</atitle><jtitle>Optics express</jtitle><date>2022-06-20</date><risdate>2022</risdate><volume>30</volume><issue>13</issue><spage>23587</spage><epage>23599</epage><pages>23587-23599</pages><issn>1094-4087</issn><eissn>1094-4087</eissn><abstract>In the spin-exchange relaxation-free (SERF) magnetometer of a perpendicular pump-probe configuration, the pump and probe beam characteristics significantly affect the performance. In this paper, an efficient evaluation of optical parameters to improve the sensitivity of a miniature magnetometer has been presented. We have determined the pump light’s optimal intensity and wavelength through theoretical analysis and the zero-field resonance experiments. Chirp signals are applied to measure the optical rotations at different probe intensities and frequencies. Through theoretical and experimental analysis of noise source characterization under different beam intensities and wavelengths, we demonstrate that dual-beam magnetometer performance is mainly limited by photon shot noise. Based on the optimum pump and probe beam parameters, we demonstrate magnetic field sensitivity of 6.3 fT/ Hz in an 87 Rb vapor cell filled with nitrogen gas, with an active measurement volume of 3 × 3 × 3 mm 3 .</abstract><doi>10.1364/OE.458827</doi><tpages>13</tpages><orcidid>https://orcid.org/0000-0002-5739-7104</orcidid><orcidid>https://orcid.org/0000-0001-6919-7129</orcidid><orcidid>https://orcid.org/0000-0001-9763-6723</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1094-4087
ispartof Optics express, 2022-06, Vol.30 (13), p.23587-23599
issn 1094-4087
1094-4087
language eng
recordid cdi_proquest_miscellaneous_2724583779
source EZB Electronic Journals Library
title Evaluation of optical parameters for a microminiature Rb vapor cell in a dual-beam SERF magnetometer
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T00%3A07%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20optical%20parameters%20for%20a%20microminiature%20Rb%20vapor%20cell%20in%20a%20dual-beam%20SERF%20magnetometer&rft.jtitle=Optics%20express&rft.au=Wang,%20Yaxiang&rft.date=2022-06-20&rft.volume=30&rft.issue=13&rft.spage=23587&rft.epage=23599&rft.pages=23587-23599&rft.issn=1094-4087&rft.eissn=1094-4087&rft_id=info:doi/10.1364/OE.458827&rft_dat=%3Cproquest_cross%3E2724583779%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c297t-1397dc7901b6eb0e4accb2c3750252899ba4ab3a1b9435b82fc69ac23ad6e8db3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2724583779&rft_id=info:pmid/&rfr_iscdi=true