Punching shear strength of flat slab corner column connections. Pt.2: fibre-reinforced concrete connections
Tests have been conducted on 16 specimens with varying reinforcement ratio, moment/shear ratio and volume friction of fibres. The method proposed in Pt.1 has been used and extended to fibre reinforced concrete interior column connections. (Abstract quotes from original text)
Saved in:
Published in: | Proceedings of the Institution of Civil Engineers. Structures and buildings 1997-02, Vol.122 (1), p.21-26 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 26 |
container_issue | 1 |
container_start_page | 21 |
container_title | Proceedings of the Institution of Civil Engineers. Structures and buildings |
container_volume | 122 |
creator | Desayi, P Seshadri, H K |
description | Tests have been conducted on 16 specimens with varying reinforcement ratio, moment/shear ratio and volume friction of fibres. The method proposed in Pt.1 has been used and extended to fibre reinforced concrete interior column connections. (Abstract quotes from original text) |
format | article |
fullrecord | <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_27281656</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>27281656</sourcerecordid><originalsourceid>FETCH-proquest_miscellaneous_272816563</originalsourceid><addsrcrecordid>eNqNyrsOwiAUAFAGTXz-A5NbDa0pPlajcezg3iBeWpRe9F76_2ri4Oh0ljMQY7XVZaa2eT4SE-abUkrrcjUW96pH23psJLdgSHIiwCa1MjrpgkmSg7lIGwmB3oS-wzeIYJOPyEtZpWWxk85fCDICjy6ShevnWIIEv3kmhs4EhvnXqVgcD-f9KXtQfPbAqe48WwjBIMSe62JdbHJd6tXf8QXFvEvl</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>27281656</pqid></control><display><type>article</type><title>Punching shear strength of flat slab corner column connections. Pt.2: fibre-reinforced concrete connections</title><source>Institution of Civil Engineers Publishing: JISC Collections:Virtual Library Archive (1836-2001)</source><creator>Desayi, P ; Seshadri, H K</creator><creatorcontrib>Desayi, P ; Seshadri, H K</creatorcontrib><description>Tests have been conducted on 16 specimens with varying reinforcement ratio, moment/shear ratio and volume friction of fibres. The method proposed in Pt.1 has been used and extended to fibre reinforced concrete interior column connections. (Abstract quotes from original text)</description><identifier>ISSN: 0965-0911</identifier><language>eng</language><ispartof>Proceedings of the Institution of Civil Engineers. Structures and buildings, 1997-02, Vol.122 (1), p.21-26</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781</link.rule.ids></links><search><creatorcontrib>Desayi, P</creatorcontrib><creatorcontrib>Seshadri, H K</creatorcontrib><title>Punching shear strength of flat slab corner column connections. Pt.2: fibre-reinforced concrete connections</title><title>Proceedings of the Institution of Civil Engineers. Structures and buildings</title><description>Tests have been conducted on 16 specimens with varying reinforcement ratio, moment/shear ratio and volume friction of fibres. The method proposed in Pt.1 has been used and extended to fibre reinforced concrete interior column connections. (Abstract quotes from original text)</description><issn>0965-0911</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1997</creationdate><recordtype>article</recordtype><recordid>eNqNyrsOwiAUAFAGTXz-A5NbDa0pPlajcezg3iBeWpRe9F76_2ri4Oh0ljMQY7XVZaa2eT4SE-abUkrrcjUW96pH23psJLdgSHIiwCa1MjrpgkmSg7lIGwmB3oS-wzeIYJOPyEtZpWWxk85fCDICjy6ShevnWIIEv3kmhs4EhvnXqVgcD-f9KXtQfPbAqe48WwjBIMSe62JdbHJd6tXf8QXFvEvl</recordid><startdate>19970201</startdate><enddate>19970201</enddate><creator>Desayi, P</creator><creator>Seshadri, H K</creator><scope>8FD</scope><scope>F28</scope><scope>FR3</scope><scope>KR7</scope></search><sort><creationdate>19970201</creationdate><title>Punching shear strength of flat slab corner column connections. Pt.2: fibre-reinforced concrete connections</title><author>Desayi, P ; Seshadri, H K</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_miscellaneous_272816563</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1997</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Desayi, P</creatorcontrib><creatorcontrib>Seshadri, H K</creatorcontrib><collection>Technology Research Database</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><jtitle>Proceedings of the Institution of Civil Engineers. Structures and buildings</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Desayi, P</au><au>Seshadri, H K</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Punching shear strength of flat slab corner column connections. Pt.2: fibre-reinforced concrete connections</atitle><jtitle>Proceedings of the Institution of Civil Engineers. Structures and buildings</jtitle><date>1997-02-01</date><risdate>1997</risdate><volume>122</volume><issue>1</issue><spage>21</spage><epage>26</epage><pages>21-26</pages><issn>0965-0911</issn><abstract>Tests have been conducted on 16 specimens with varying reinforcement ratio, moment/shear ratio and volume friction of fibres. The method proposed in Pt.1 has been used and extended to fibre reinforced concrete interior column connections. (Abstract quotes from original text)</abstract></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0965-0911 |
ispartof | Proceedings of the Institution of Civil Engineers. Structures and buildings, 1997-02, Vol.122 (1), p.21-26 |
issn | 0965-0911 |
language | eng |
recordid | cdi_proquest_miscellaneous_27281656 |
source | Institution of Civil Engineers Publishing: JISC Collections:Virtual Library Archive (1836-2001) |
title | Punching shear strength of flat slab corner column connections. Pt.2: fibre-reinforced concrete connections |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-20T03%3A01%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Punching%20shear%20strength%20of%20flat%20slab%20corner%20column%20connections.%20Pt.2:%20fibre-reinforced%20concrete%20connections&rft.jtitle=Proceedings%20of%20the%20Institution%20of%20Civil%20Engineers.%20Structures%20and%20buildings&rft.au=Desayi,%20P&rft.date=1997-02-01&rft.volume=122&rft.issue=1&rft.spage=21&rft.epage=26&rft.pages=21-26&rft.issn=0965-0911&rft_id=info:doi/&rft_dat=%3Cproquest%3E27281656%3C/proquest%3E%3Cgrp_id%3Ecdi_FETCH-proquest_miscellaneous_272816563%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=27281656&rft_id=info:pmid/&rfr_iscdi=true |