Loading…
Determination of Sequestration Capacities of Iron Control Chemicals
Titrimetry with electronanalytical endpoint detection was used to determine sequestration capacities of polyphosphates for Fe 2+ and Fe 3+. These methods have the advantage of directly monitoring sequestration of the metal ions. Potentiometry with a divalent ion ion-selective electrode was used to m...
Saved in:
Published in: | Journal of environmental engineering (New York, N.Y.) N.Y.), 1995-01, Vol.121 (1), p.108-112 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Titrimetry with electronanalytical endpoint detection was used to determine sequestration capacities of polyphosphates for Fe 2+ and Fe 3+. These methods have the advantage of directly monitoring sequestration of the metal ions. Potentiometry with a divalent ion ion-selective electrode was used to monitor sequestration of Fe 2+; polarography was used to monitor sequestration of Fe 3+. Four commercial liquid polyphosphate formulations, a Zn-orthophosphate, a silicate formulation, two solid polyphosphates, and pyrophosphate were studied. No significant difference was found in sequestration capacities for either metal ion among the polyphosphates. Polyphosphates were found to sequester only about 14% as much Fe 2+ as Fe 3+. The polarographic titration affords an efficient, precise method of studying factors affecting sequestration of iron by polyphosphates. |
---|---|
ISSN: | 0733-9372 1943-7870 |
DOI: | 10.1061/(ASCE)0733-9372(1995)121:1(108) |