Loading…

Evaluation of the ESR fast detector and Improve® ESR analyzer as modified Westergren methods for erythrocyte sedimentation rate

The erythrocyte sedimentation rate (ESR) has been commonly ordered in hematology laboratories and used to screen for monitoring responses to therapy and identifying inflammatory conditions. To overcome the limitations of traditional ESR measurements, various methods have been developed and compared...

Full description

Saved in:
Bibliographic Details
Published in:Scandinavian journal of clinical and laboratory investigation 2022-12, Vol.82 (7-8), p.581-587
Main Authors: Chomean, Sirinart, Thamwarokun, Areenuch, Jitsuvantaya, Sumittra, Attapong, Jirapat, Kaset, Chollanot
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The erythrocyte sedimentation rate (ESR) has been commonly ordered in hematology laboratories and used to screen for monitoring responses to therapy and identifying inflammatory conditions. To overcome the limitations of traditional ESR measurements, various methods have been developed and compared to the established reference method. This study evaluates the analytical performance of ESR fast detector and Improve ® ESR analyzer compared to the reference method. Method validation and comparison were performed in 189 volunteer blood samples according to the International Council for Standardization in Hematology recommendations. The analytical efficacy of ESR fast detector and Improve ® ESR analyzer was also assessed and compared with the reference method and C-reactive protein (CRP) levels. The results demonstrated that the precision of ESR fast detector and Improve ® ESR analyzer was considered as the acceptance criterion for the ESR measurement. The method comparison analysis between the two modified Westergren methods and reference method demonstrated a strong correlation with the Spearman's rank correlation coefficient of 0.94, with a mean difference of −2.1 and −7.7 mm/h in the ESR fast detector and Improve ® ESR analyzer, respectively. Analysis of the area under the receiver operating curve illustrated a high analytical performance compared to the reference method and CRP level. The measurement of ESR level using the ESR fast detector and Improve ® ESR analyzer is a reliable method and has a high analytical performance, which can be used instead of the reference method for screening inflammatory conditions.
ISSN:0036-5513
1502-7686
DOI:10.1080/00365513.2022.2144434