Loading…
Evaluating Subtle Pathological Changes in Early Myocardial Ischemia Using Spectral Histopathology
Early myocardial ischemia (EMI) is morphologically challenging, and the results from conventional histological staining may be subjective, imprecise, or even silent. The size of myocardial necrosis determines the acute and long-term mortality of EMI. The precise diagnosis of myocardial ischemia is c...
Saved in:
Published in: | Analytical chemistry (Washington) 2022-12, Vol.94 (49), p.17112-17120 |
---|---|
Main Authors: | , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-a376t-fd7a2745f43036127f9f6ff0aa4cc983896e542eaf88f8b6ddd40c986b42d7b53 |
---|---|
cites | cdi_FETCH-LOGICAL-a376t-fd7a2745f43036127f9f6ff0aa4cc983896e542eaf88f8b6ddd40c986b42d7b53 |
container_end_page | 17120 |
container_issue | 49 |
container_start_page | 17112 |
container_title | Analytical chemistry (Washington) |
container_volume | 94 |
creator | Tian, Tian Zhang, Jianhua Xiong, Ling Yu, Haixing Deng, Kaifei Liao, Xinbiao Zhang, Fu Huang, Ping Zhang, Ji Chen, Yijiu |
description | Early myocardial ischemia (EMI) is morphologically challenging, and the results from conventional histological staining may be subjective, imprecise, or even silent. The size of myocardial necrosis determines the acute and long-term mortality of EMI. The precise diagnosis of myocardial ischemia is critical for both clinical management and forensic investigation. Fourier transform infrared (FTIR) spectroscopic imaging is a highly sensitive tool for detecting protein conformations and imaging protein profiles. The aim of this study was to evaluate the application of FTIR imaging with multivariate analysis to detect biochemical changes in the protein conformation in the early phase of myocardial ischemia and to visually classify different disease states. The spectra and curve fitting results revealed that the total protein content decreased significantly in the EMI group and that the α-helix content of the secondary protein structure continuously decreased as ischemia progressed, while the β-sheet content increased. Differences in the control and EMI groups and perfused and ischemic myocardium were confirmed using principal component analysis and partial least squares discriminant analysis. Next, two support vector machine classifiers were effectively created. The accuracy, recall, and precision were 99.98, 99.96, and 100.00%, respectively, to differentiate the EMI group from the control group and 99.25, 98.95, and 99.54%, respectively, to differentiate perfused and ischemic myocardium. Ultimately, high EMI diagnostic accuracy was achieved with 100.00% recall and 100.00% precision, and ischemic myocardium diagnostic accuracy was achieved with 99.30% recall and 99.53% precision for the test set. This pilot study demonstrated that FTIR imaging is a powerful automated quantitative analysis tool to detect EMI without morphological changes and will improve diagnostic accuracy and patient prognosis. |
doi_str_mv | 10.1021/acs.analchem.2c03368 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2742659186</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2742659186</sourcerecordid><originalsourceid>FETCH-LOGICAL-a376t-fd7a2745f43036127f9f6ff0aa4cc983896e542eaf88f8b6ddd40c986b42d7b53</originalsourceid><addsrcrecordid>eNp9kc1Lw0AQxRdRtFb_A5GAFy-psx_ZbI5S6gcoCuo5TDa7bWSb1N1E6H_v1lYPHjwNzPzeG3iPkDMKEwqMXqEOE2zR6YVZTpgGzqXaIyOaMUilUmyfjACApywHOCLHIbwDUApUHpIjLoVgohAjgrNPdAP2TTtPXoaqdyZ5xn7RuW7eaHTJdIHt3ISkaZMZerdOHtedRl838XYfNr8bTN7Ct3xldO_j_q4JfbfauaxPyIFFF8zpbo7J283sdXqXPjzd3k-vH1LkuexTW-fIcpFZwYFLynJbWGktIAqtC8VVIU0mmEGrlFWVrOtaQDzISrA6rzI-Jpdb35XvPgYT-nLZBG2cw9Z0QyijOZNZQZWM6MUf9L0bfMxyQ2U5ZSKLyY2J2FLadyF4Y8uVb5bo1yWFclNBGSsofyoodxVE2fnOfKiWpv4V_WQeAdgCG_nv4389vwCgKZYc</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2757124500</pqid></control><display><type>article</type><title>Evaluating Subtle Pathological Changes in Early Myocardial Ischemia Using Spectral Histopathology</title><source>American Chemical Society:Jisc Collections:American Chemical Society Read & Publish Agreement 2022-2024 (Reading list)</source><creator>Tian, Tian ; Zhang, Jianhua ; Xiong, Ling ; Yu, Haixing ; Deng, Kaifei ; Liao, Xinbiao ; Zhang, Fu ; Huang, Ping ; Zhang, Ji ; Chen, Yijiu</creator><creatorcontrib>Tian, Tian ; Zhang, Jianhua ; Xiong, Ling ; Yu, Haixing ; Deng, Kaifei ; Liao, Xinbiao ; Zhang, Fu ; Huang, Ping ; Zhang, Ji ; Chen, Yijiu</creatorcontrib><description>Early myocardial ischemia (EMI) is morphologically challenging, and the results from conventional histological staining may be subjective, imprecise, or even silent. The size of myocardial necrosis determines the acute and long-term mortality of EMI. The precise diagnosis of myocardial ischemia is critical for both clinical management and forensic investigation. Fourier transform infrared (FTIR) spectroscopic imaging is a highly sensitive tool for detecting protein conformations and imaging protein profiles. The aim of this study was to evaluate the application of FTIR imaging with multivariate analysis to detect biochemical changes in the protein conformation in the early phase of myocardial ischemia and to visually classify different disease states. The spectra and curve fitting results revealed that the total protein content decreased significantly in the EMI group and that the α-helix content of the secondary protein structure continuously decreased as ischemia progressed, while the β-sheet content increased. Differences in the control and EMI groups and perfused and ischemic myocardium were confirmed using principal component analysis and partial least squares discriminant analysis. Next, two support vector machine classifiers were effectively created. The accuracy, recall, and precision were 99.98, 99.96, and 100.00%, respectively, to differentiate the EMI group from the control group and 99.25, 98.95, and 99.54%, respectively, to differentiate perfused and ischemic myocardium. Ultimately, high EMI diagnostic accuracy was achieved with 100.00% recall and 100.00% precision, and ischemic myocardium diagnostic accuracy was achieved with 99.30% recall and 99.53% precision for the test set. This pilot study demonstrated that FTIR imaging is a powerful automated quantitative analysis tool to detect EMI without morphological changes and will improve diagnostic accuracy and patient prognosis.</description><identifier>ISSN: 0003-2700</identifier><identifier>EISSN: 1520-6882</identifier><identifier>DOI: 10.1021/acs.analchem.2c03368</identifier><identifier>PMID: 36442494</identifier><language>eng</language><publisher>United States: American Chemical Society</publisher><subject>Accuracy ; Chemistry ; Curve fitting ; Discriminant analysis ; Evaluation ; Forensic science ; Fourier transforms ; Histopathology ; Humans ; Infrared imaging ; Infrared spectroscopy ; Ischemia ; Least-Squares Analysis ; Medical imaging ; Morphology ; Multivariate analysis ; Myocardial Infarction - pathology ; Myocardial ischemia ; Myocardial Ischemia - diagnosis ; Myocardium ; Necrosis ; Pilot Projects ; Principal components analysis ; Protein structure ; Proteins ; Proteins - chemistry ; Recall ; Spectroscopy, Fourier Transform Infrared - methods ; Support vector machines</subject><ispartof>Analytical chemistry (Washington), 2022-12, Vol.94 (49), p.17112-17120</ispartof><rights>2022 American Chemical Society</rights><rights>Copyright American Chemical Society Dec 13, 2022</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a376t-fd7a2745f43036127f9f6ff0aa4cc983896e542eaf88f8b6ddd40c986b42d7b53</citedby><cites>FETCH-LOGICAL-a376t-fd7a2745f43036127f9f6ff0aa4cc983896e542eaf88f8b6ddd40c986b42d7b53</cites><orcidid>0000-0002-6972-9938</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/36442494$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Tian, Tian</creatorcontrib><creatorcontrib>Zhang, Jianhua</creatorcontrib><creatorcontrib>Xiong, Ling</creatorcontrib><creatorcontrib>Yu, Haixing</creatorcontrib><creatorcontrib>Deng, Kaifei</creatorcontrib><creatorcontrib>Liao, Xinbiao</creatorcontrib><creatorcontrib>Zhang, Fu</creatorcontrib><creatorcontrib>Huang, Ping</creatorcontrib><creatorcontrib>Zhang, Ji</creatorcontrib><creatorcontrib>Chen, Yijiu</creatorcontrib><title>Evaluating Subtle Pathological Changes in Early Myocardial Ischemia Using Spectral Histopathology</title><title>Analytical chemistry (Washington)</title><addtitle>Anal. Chem</addtitle><description>Early myocardial ischemia (EMI) is morphologically challenging, and the results from conventional histological staining may be subjective, imprecise, or even silent. The size of myocardial necrosis determines the acute and long-term mortality of EMI. The precise diagnosis of myocardial ischemia is critical for both clinical management and forensic investigation. Fourier transform infrared (FTIR) spectroscopic imaging is a highly sensitive tool for detecting protein conformations and imaging protein profiles. The aim of this study was to evaluate the application of FTIR imaging with multivariate analysis to detect biochemical changes in the protein conformation in the early phase of myocardial ischemia and to visually classify different disease states. The spectra and curve fitting results revealed that the total protein content decreased significantly in the EMI group and that the α-helix content of the secondary protein structure continuously decreased as ischemia progressed, while the β-sheet content increased. Differences in the control and EMI groups and perfused and ischemic myocardium were confirmed using principal component analysis and partial least squares discriminant analysis. Next, two support vector machine classifiers were effectively created. The accuracy, recall, and precision were 99.98, 99.96, and 100.00%, respectively, to differentiate the EMI group from the control group and 99.25, 98.95, and 99.54%, respectively, to differentiate perfused and ischemic myocardium. Ultimately, high EMI diagnostic accuracy was achieved with 100.00% recall and 100.00% precision, and ischemic myocardium diagnostic accuracy was achieved with 99.30% recall and 99.53% precision for the test set. This pilot study demonstrated that FTIR imaging is a powerful automated quantitative analysis tool to detect EMI without morphological changes and will improve diagnostic accuracy and patient prognosis.</description><subject>Accuracy</subject><subject>Chemistry</subject><subject>Curve fitting</subject><subject>Discriminant analysis</subject><subject>Evaluation</subject><subject>Forensic science</subject><subject>Fourier transforms</subject><subject>Histopathology</subject><subject>Humans</subject><subject>Infrared imaging</subject><subject>Infrared spectroscopy</subject><subject>Ischemia</subject><subject>Least-Squares Analysis</subject><subject>Medical imaging</subject><subject>Morphology</subject><subject>Multivariate analysis</subject><subject>Myocardial Infarction - pathology</subject><subject>Myocardial ischemia</subject><subject>Myocardial Ischemia - diagnosis</subject><subject>Myocardium</subject><subject>Necrosis</subject><subject>Pilot Projects</subject><subject>Principal components analysis</subject><subject>Protein structure</subject><subject>Proteins</subject><subject>Proteins - chemistry</subject><subject>Recall</subject><subject>Spectroscopy, Fourier Transform Infrared - methods</subject><subject>Support vector machines</subject><issn>0003-2700</issn><issn>1520-6882</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNp9kc1Lw0AQxRdRtFb_A5GAFy-psx_ZbI5S6gcoCuo5TDa7bWSb1N1E6H_v1lYPHjwNzPzeG3iPkDMKEwqMXqEOE2zR6YVZTpgGzqXaIyOaMUilUmyfjACApywHOCLHIbwDUApUHpIjLoVgohAjgrNPdAP2TTtPXoaqdyZ5xn7RuW7eaHTJdIHt3ISkaZMZerdOHtedRl838XYfNr8bTN7Ct3xldO_j_q4JfbfauaxPyIFFF8zpbo7J283sdXqXPjzd3k-vH1LkuexTW-fIcpFZwYFLynJbWGktIAqtC8VVIU0mmEGrlFWVrOtaQDzISrA6rzI-Jpdb35XvPgYT-nLZBG2cw9Z0QyijOZNZQZWM6MUf9L0bfMxyQ2U5ZSKLyY2J2FLadyF4Y8uVb5bo1yWFclNBGSsofyoodxVE2fnOfKiWpv4V_WQeAdgCG_nv4389vwCgKZYc</recordid><startdate>20221213</startdate><enddate>20221213</enddate><creator>Tian, Tian</creator><creator>Zhang, Jianhua</creator><creator>Xiong, Ling</creator><creator>Yu, Haixing</creator><creator>Deng, Kaifei</creator><creator>Liao, Xinbiao</creator><creator>Zhang, Fu</creator><creator>Huang, Ping</creator><creator>Zhang, Ji</creator><creator>Chen, Yijiu</creator><general>American Chemical Society</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7TA</scope><scope>7TB</scope><scope>7TM</scope><scope>7U5</scope><scope>7U7</scope><scope>7U9</scope><scope>8BQ</scope><scope>8FD</scope><scope>C1K</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>H8G</scope><scope>H94</scope><scope>JG9</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>P64</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-6972-9938</orcidid></search><sort><creationdate>20221213</creationdate><title>Evaluating Subtle Pathological Changes in Early Myocardial Ischemia Using Spectral Histopathology</title><author>Tian, Tian ; Zhang, Jianhua ; Xiong, Ling ; Yu, Haixing ; Deng, Kaifei ; Liao, Xinbiao ; Zhang, Fu ; Huang, Ping ; Zhang, Ji ; Chen, Yijiu</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a376t-fd7a2745f43036127f9f6ff0aa4cc983896e542eaf88f8b6ddd40c986b42d7b53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Accuracy</topic><topic>Chemistry</topic><topic>Curve fitting</topic><topic>Discriminant analysis</topic><topic>Evaluation</topic><topic>Forensic science</topic><topic>Fourier transforms</topic><topic>Histopathology</topic><topic>Humans</topic><topic>Infrared imaging</topic><topic>Infrared spectroscopy</topic><topic>Ischemia</topic><topic>Least-Squares Analysis</topic><topic>Medical imaging</topic><topic>Morphology</topic><topic>Multivariate analysis</topic><topic>Myocardial Infarction - pathology</topic><topic>Myocardial ischemia</topic><topic>Myocardial Ischemia - diagnosis</topic><topic>Myocardium</topic><topic>Necrosis</topic><topic>Pilot Projects</topic><topic>Principal components analysis</topic><topic>Protein structure</topic><topic>Proteins</topic><topic>Proteins - chemistry</topic><topic>Recall</topic><topic>Spectroscopy, Fourier Transform Infrared - methods</topic><topic>Support vector machines</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Tian, Tian</creatorcontrib><creatorcontrib>Zhang, Jianhua</creatorcontrib><creatorcontrib>Xiong, Ling</creatorcontrib><creatorcontrib>Yu, Haixing</creatorcontrib><creatorcontrib>Deng, Kaifei</creatorcontrib><creatorcontrib>Liao, Xinbiao</creatorcontrib><creatorcontrib>Zhang, Fu</creatorcontrib><creatorcontrib>Huang, Ping</creatorcontrib><creatorcontrib>Zhang, Ji</creatorcontrib><creatorcontrib>Chen, Yijiu</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics & Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Materials Business File</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Nucleic Acids Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Toxicology Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Copper Technical Reference Library</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Analytical chemistry (Washington)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Tian, Tian</au><au>Zhang, Jianhua</au><au>Xiong, Ling</au><au>Yu, Haixing</au><au>Deng, Kaifei</au><au>Liao, Xinbiao</au><au>Zhang, Fu</au><au>Huang, Ping</au><au>Zhang, Ji</au><au>Chen, Yijiu</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluating Subtle Pathological Changes in Early Myocardial Ischemia Using Spectral Histopathology</atitle><jtitle>Analytical chemistry (Washington)</jtitle><addtitle>Anal. Chem</addtitle><date>2022-12-13</date><risdate>2022</risdate><volume>94</volume><issue>49</issue><spage>17112</spage><epage>17120</epage><pages>17112-17120</pages><issn>0003-2700</issn><eissn>1520-6882</eissn><abstract>Early myocardial ischemia (EMI) is morphologically challenging, and the results from conventional histological staining may be subjective, imprecise, or even silent. The size of myocardial necrosis determines the acute and long-term mortality of EMI. The precise diagnosis of myocardial ischemia is critical for both clinical management and forensic investigation. Fourier transform infrared (FTIR) spectroscopic imaging is a highly sensitive tool for detecting protein conformations and imaging protein profiles. The aim of this study was to evaluate the application of FTIR imaging with multivariate analysis to detect biochemical changes in the protein conformation in the early phase of myocardial ischemia and to visually classify different disease states. The spectra and curve fitting results revealed that the total protein content decreased significantly in the EMI group and that the α-helix content of the secondary protein structure continuously decreased as ischemia progressed, while the β-sheet content increased. Differences in the control and EMI groups and perfused and ischemic myocardium were confirmed using principal component analysis and partial least squares discriminant analysis. Next, two support vector machine classifiers were effectively created. The accuracy, recall, and precision were 99.98, 99.96, and 100.00%, respectively, to differentiate the EMI group from the control group and 99.25, 98.95, and 99.54%, respectively, to differentiate perfused and ischemic myocardium. Ultimately, high EMI diagnostic accuracy was achieved with 100.00% recall and 100.00% precision, and ischemic myocardium diagnostic accuracy was achieved with 99.30% recall and 99.53% precision for the test set. This pilot study demonstrated that FTIR imaging is a powerful automated quantitative analysis tool to detect EMI without morphological changes and will improve diagnostic accuracy and patient prognosis.</abstract><cop>United States</cop><pub>American Chemical Society</pub><pmid>36442494</pmid><doi>10.1021/acs.analchem.2c03368</doi><tpages>9</tpages><orcidid>https://orcid.org/0000-0002-6972-9938</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0003-2700 |
ispartof | Analytical chemistry (Washington), 2022-12, Vol.94 (49), p.17112-17120 |
issn | 0003-2700 1520-6882 |
language | eng |
recordid | cdi_proquest_miscellaneous_2742659186 |
source | American Chemical Society:Jisc Collections:American Chemical Society Read & Publish Agreement 2022-2024 (Reading list) |
subjects | Accuracy Chemistry Curve fitting Discriminant analysis Evaluation Forensic science Fourier transforms Histopathology Humans Infrared imaging Infrared spectroscopy Ischemia Least-Squares Analysis Medical imaging Morphology Multivariate analysis Myocardial Infarction - pathology Myocardial ischemia Myocardial Ischemia - diagnosis Myocardium Necrosis Pilot Projects Principal components analysis Protein structure Proteins Proteins - chemistry Recall Spectroscopy, Fourier Transform Infrared - methods Support vector machines |
title | Evaluating Subtle Pathological Changes in Early Myocardial Ischemia Using Spectral Histopathology |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T06%3A18%3A54IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluating%20Subtle%20Pathological%20Changes%20in%20Early%20Myocardial%20Ischemia%20Using%20Spectral%20Histopathology&rft.jtitle=Analytical%20chemistry%20(Washington)&rft.au=Tian,%20Tian&rft.date=2022-12-13&rft.volume=94&rft.issue=49&rft.spage=17112&rft.epage=17120&rft.pages=17112-17120&rft.issn=0003-2700&rft.eissn=1520-6882&rft_id=info:doi/10.1021/acs.analchem.2c03368&rft_dat=%3Cproquest_cross%3E2742659186%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-a376t-fd7a2745f43036127f9f6ff0aa4cc983896e542eaf88f8b6ddd40c986b42d7b53%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2757124500&rft_id=info:pmid/36442494&rfr_iscdi=true |