Loading…

Intermittent-Discharge Lagoons for Use in Cold Regions

Lagoon treatment is a common wastewater-treatment option for small communities. In cold regions the design and use of lagoons must consider some unique concerns that impact performance due to cold climates. Many of the concerns can be met by the use of intermittent-discharge lagoons. Presented is a...

Full description

Saved in:
Bibliographic Details
Published in:Journal of cold regions engineering 1995-12, Vol.9 (4), p.183-194
Main Authors: Prince, Dennis S, Smith, Daniel W, Stanley, Stephen J
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-a434t-e6a35f3d86a1971ff779a542807043932c3121d83281e1d81014578c72498f613
cites cdi_FETCH-LOGICAL-a434t-e6a35f3d86a1971ff779a542807043932c3121d83281e1d81014578c72498f613
container_end_page 194
container_issue 4
container_start_page 183
container_title Journal of cold regions engineering
container_volume 9
creator Prince, Dennis S
Smith, Daniel W
Stanley, Stephen J
description Lagoon treatment is a common wastewater-treatment option for small communities. In cold regions the design and use of lagoons must consider some unique concerns that impact performance due to cold climates. Many of the concerns can be met by the use of intermittent-discharge lagoons. Presented is a study of intermittent-discharge lagoons in Alberta, Canada. The performance and factors influencing performance were determined by analysis of a large database of effluent quality. Effluent quality was compared to other treatment alternatives. In addition, public concerns and costs involved with lagoon treatment were determined through a survey and compared to other treatment alternatives. The existing data demonstrate that properly designed intermittent-discharge lagoons are capable of producing effluent quality that is superior to the effluent produced by the mechanical treatment facilities in the same region. The survey of operators showed that the vast majority of lagoon facilities do not receive complaints, and the costs of lagoon treatment are shown to be generally more cost-effective than other treatment alternatives.
doi_str_mv 10.1061/(ASCE)0887-381X(1995)9:4(183)
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_27474363</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>27474363</sourcerecordid><originalsourceid>FETCH-LOGICAL-a434t-e6a35f3d86a1971ff779a542807043932c3121d83281e1d81014578c72498f613</originalsourceid><addsrcrecordid>eNqNkEFLwzAUx4MoOKffoQeV7VDNS16bRLyMOnUyENSJtxC6dFa6dibdwW9vuumOYiB5Ifzyf48fIWdAL4CmcDkYPWfjIZVSxFzC2wCUSobqCgcg-XCP9EAhjxNUyT7p7ahDcuT9B6WUU8QeSSd1a92ybFtbt_FN6fN34xY2mppF09Q-KhoXzbyNyjrKmmoePdlFGd6PyUFhKm9PfmqfzG7HL9l9PH28m2SjaWyQYxvb1PCk4HOZGlACikIIZRJkkgqKXHGWc2Awl5xJsKECBUyEzAVDJYsUeJ-cb3NXrvlcW9_qZRjRVpWpbbP2mgkUyFP-L5BKZAG83oK5a7x3ttArVy6N-9JAdadV606r7oTpTpjutGqlUQet4fvpTx_jc1MVztR56XcZTNGEpRiw1y0WKKs_mrWrgyb9kD3djSe0W2pzYtghdnOH3wH-6v8NDnWNUg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>27470842</pqid></control><display><type>article</type><title>Intermittent-Discharge Lagoons for Use in Cold Regions</title><source>ASCE Library (civil engineering)</source><creator>Prince, Dennis S ; Smith, Daniel W ; Stanley, Stephen J</creator><creatorcontrib>Prince, Dennis S ; Smith, Daniel W ; Stanley, Stephen J</creatorcontrib><description>Lagoon treatment is a common wastewater-treatment option for small communities. In cold regions the design and use of lagoons must consider some unique concerns that impact performance due to cold climates. Many of the concerns can be met by the use of intermittent-discharge lagoons. Presented is a study of intermittent-discharge lagoons in Alberta, Canada. The performance and factors influencing performance were determined by analysis of a large database of effluent quality. Effluent quality was compared to other treatment alternatives. In addition, public concerns and costs involved with lagoon treatment were determined through a survey and compared to other treatment alternatives. The existing data demonstrate that properly designed intermittent-discharge lagoons are capable of producing effluent quality that is superior to the effluent produced by the mechanical treatment facilities in the same region. The survey of operators showed that the vast majority of lagoon facilities do not receive complaints, and the costs of lagoon treatment are shown to be generally more cost-effective than other treatment alternatives.</description><identifier>ISSN: 0887-381X</identifier><identifier>EISSN: 1943-5495</identifier><identifier>DOI: 10.1061/(ASCE)0887-381X(1995)9:4(183)</identifier><identifier>CODEN: JCRGEI</identifier><language>eng</language><publisher>Reston, VA: American Society of Civil Engineers</publisher><subject>Applied sciences ; Exact sciences and technology ; Other wastewaters ; Pollution ; TECHNICAL PAPERS ; Wastewaters ; Water treatment and pollution</subject><ispartof>Journal of cold regions engineering, 1995-12, Vol.9 (4), p.183-194</ispartof><rights>Copyright © 1995 American Society of Civil Engineers</rights><rights>1996 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a434t-e6a35f3d86a1971ff779a542807043932c3121d83281e1d81014578c72498f613</citedby><cites>FETCH-LOGICAL-a434t-e6a35f3d86a1971ff779a542807043932c3121d83281e1d81014578c72498f613</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttp://ascelibrary.org/doi/pdf/10.1061/(ASCE)0887-381X(1995)9:4(183)$$EPDF$$P50$$Gasce$$H</linktopdf><linktohtml>$$Uhttp://ascelibrary.org/doi/abs/10.1061/(ASCE)0887-381X(1995)9:4(183)$$EHTML$$P50$$Gasce$$H</linktohtml><link.rule.ids>314,780,784,3252,10068,27924,27925,76191,76199</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=2905264$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Prince, Dennis S</creatorcontrib><creatorcontrib>Smith, Daniel W</creatorcontrib><creatorcontrib>Stanley, Stephen J</creatorcontrib><title>Intermittent-Discharge Lagoons for Use in Cold Regions</title><title>Journal of cold regions engineering</title><description>Lagoon treatment is a common wastewater-treatment option for small communities. In cold regions the design and use of lagoons must consider some unique concerns that impact performance due to cold climates. Many of the concerns can be met by the use of intermittent-discharge lagoons. Presented is a study of intermittent-discharge lagoons in Alberta, Canada. The performance and factors influencing performance were determined by analysis of a large database of effluent quality. Effluent quality was compared to other treatment alternatives. In addition, public concerns and costs involved with lagoon treatment were determined through a survey and compared to other treatment alternatives. The existing data demonstrate that properly designed intermittent-discharge lagoons are capable of producing effluent quality that is superior to the effluent produced by the mechanical treatment facilities in the same region. The survey of operators showed that the vast majority of lagoon facilities do not receive complaints, and the costs of lagoon treatment are shown to be generally more cost-effective than other treatment alternatives.</description><subject>Applied sciences</subject><subject>Exact sciences and technology</subject><subject>Other wastewaters</subject><subject>Pollution</subject><subject>TECHNICAL PAPERS</subject><subject>Wastewaters</subject><subject>Water treatment and pollution</subject><issn>0887-381X</issn><issn>1943-5495</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1995</creationdate><recordtype>article</recordtype><recordid>eNqNkEFLwzAUx4MoOKffoQeV7VDNS16bRLyMOnUyENSJtxC6dFa6dibdwW9vuumOYiB5Ifzyf48fIWdAL4CmcDkYPWfjIZVSxFzC2wCUSobqCgcg-XCP9EAhjxNUyT7p7ahDcuT9B6WUU8QeSSd1a92ybFtbt_FN6fN34xY2mppF09Q-KhoXzbyNyjrKmmoePdlFGd6PyUFhKm9PfmqfzG7HL9l9PH28m2SjaWyQYxvb1PCk4HOZGlACikIIZRJkkgqKXHGWc2Awl5xJsKECBUyEzAVDJYsUeJ-cb3NXrvlcW9_qZRjRVpWpbbP2mgkUyFP-L5BKZAG83oK5a7x3ttArVy6N-9JAdadV606r7oTpTpjutGqlUQet4fvpTx_jc1MVztR56XcZTNGEpRiw1y0WKKs_mrWrgyb9kD3djSe0W2pzYtghdnOH3wH-6v8NDnWNUg</recordid><startdate>19951201</startdate><enddate>19951201</enddate><creator>Prince, Dennis S</creator><creator>Smith, Daniel W</creator><creator>Stanley, Stephen J</creator><general>American Society of Civil Engineers</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SC</scope><scope>8FD</scope><scope>JQ2</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>FR3</scope><scope>KR7</scope></search><sort><creationdate>19951201</creationdate><title>Intermittent-Discharge Lagoons for Use in Cold Regions</title><author>Prince, Dennis S ; Smith, Daniel W ; Stanley, Stephen J</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a434t-e6a35f3d86a1971ff779a542807043932c3121d83281e1d81014578c72498f613</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1995</creationdate><topic>Applied sciences</topic><topic>Exact sciences and technology</topic><topic>Other wastewaters</topic><topic>Pollution</topic><topic>TECHNICAL PAPERS</topic><topic>Wastewaters</topic><topic>Water treatment and pollution</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Prince, Dennis S</creatorcontrib><creatorcontrib>Smith, Daniel W</creatorcontrib><creatorcontrib>Stanley, Stephen J</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Computer and Information Systems Abstracts</collection><collection>Technology Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><jtitle>Journal of cold regions engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Prince, Dennis S</au><au>Smith, Daniel W</au><au>Stanley, Stephen J</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Intermittent-Discharge Lagoons for Use in Cold Regions</atitle><jtitle>Journal of cold regions engineering</jtitle><date>1995-12-01</date><risdate>1995</risdate><volume>9</volume><issue>4</issue><spage>183</spage><epage>194</epage><pages>183-194</pages><issn>0887-381X</issn><eissn>1943-5495</eissn><coden>JCRGEI</coden><abstract>Lagoon treatment is a common wastewater-treatment option for small communities. In cold regions the design and use of lagoons must consider some unique concerns that impact performance due to cold climates. Many of the concerns can be met by the use of intermittent-discharge lagoons. Presented is a study of intermittent-discharge lagoons in Alberta, Canada. The performance and factors influencing performance were determined by analysis of a large database of effluent quality. Effluent quality was compared to other treatment alternatives. In addition, public concerns and costs involved with lagoon treatment were determined through a survey and compared to other treatment alternatives. The existing data demonstrate that properly designed intermittent-discharge lagoons are capable of producing effluent quality that is superior to the effluent produced by the mechanical treatment facilities in the same region. The survey of operators showed that the vast majority of lagoon facilities do not receive complaints, and the costs of lagoon treatment are shown to be generally more cost-effective than other treatment alternatives.</abstract><cop>Reston, VA</cop><pub>American Society of Civil Engineers</pub><doi>10.1061/(ASCE)0887-381X(1995)9:4(183)</doi><tpages>12</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0887-381X
ispartof Journal of cold regions engineering, 1995-12, Vol.9 (4), p.183-194
issn 0887-381X
1943-5495
language eng
recordid cdi_proquest_miscellaneous_27474363
source ASCE Library (civil engineering)
subjects Applied sciences
Exact sciences and technology
Other wastewaters
Pollution
TECHNICAL PAPERS
Wastewaters
Water treatment and pollution
title Intermittent-Discharge Lagoons for Use in Cold Regions
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-20T14%3A09%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Intermittent-Discharge%20Lagoons%20for%20Use%20in%20Cold%20Regions&rft.jtitle=Journal%20of%20cold%20regions%20engineering&rft.au=Prince,%20Dennis%20S&rft.date=1995-12-01&rft.volume=9&rft.issue=4&rft.spage=183&rft.epage=194&rft.pages=183-194&rft.issn=0887-381X&rft.eissn=1943-5495&rft.coden=JCRGEI&rft_id=info:doi/10.1061/(ASCE)0887-381X(1995)9:4(183)&rft_dat=%3Cproquest_cross%3E27474363%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-a434t-e6a35f3d86a1971ff779a542807043932c3121d83281e1d81014578c72498f613%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=27470842&rft_id=info:pmid/&rfr_iscdi=true